My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
811 94TH ST SE 2021 Plans 2022-10-24
>
Address Records
>
94TH ST SE
>
811
>
Plans
>
811 94TH ST SE 2021 Plans 2022-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2022 2:35:59 PM
Creation date
10/24/2022 2:32:50 PM
Metadata
Fields
Template:
Address Document
Street Name
94TH ST SE
Street Number
811
Permit
B2111-063
Year
2021
Notes
RESIDENTIAL ALTERATIONS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXI5TIN6ROOF FRAMING <br />R503.1.1 Building envelope. Building envelope assemblies that are part of the alteration shall comply with Section <br />R402.1.1 or R402.1.4, Sections R402.2.1 through R402.2.11, R402.3.1, R402.3.2, R402.4.3 and R402.4.4. <br />Exception: The following alterations need not comply with the requirements for new construction provided <br />the energy use of the building is not increased: <br />1. Storm windows installed over existing fenestration. <br />2. Existing ceiling, wall or floor cavities exposed during construction provided that these cavities are filled <br />with insulation. 2x4 framed walls shall be insulated to a minimum of R-15 and 2x6 framed walls shall be <br />insulated to a minimum of R-21. <br />3. Construction where the existing roof, wall or floor cavity is not exposed. <br />4. Roof recover. <br />5. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing <br />shall be insulated either above or below the sheathing. <br />6. Surface -applied window film installed on existing single pane fenestration assemblies to reduce solar <br />heat gain provided the code does not require the glazing fenestration to be replaced. <br />R503.1.1.1 Replacement fenestration. Where some or all of an existing fenestration unit is replaced with a new <br />fenestration product, including sash and glazing, the replacement fenestration unit shall meet the applicable <br />requirements for U -factor and SHGC in Table R402.1.1. Where more than one replacement fenestration unit is being <br />installed, an area -weighted average of the U-factor and SHGC of all replacement fenestration shall be permitted to be <br />used to demonstrate compliance. <br />R503.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the <br />alteration shall comply with Section R403. <br />Exceptions: <br />1. Where ducts from an existing heating and cooling system are extended, duct systems with less than 40 linear feet in <br />unconditioned spaces shall not be required to be tested in accordance with Section R403.2.2. <br />2. Existing duct systems constructed, insulated or sealed with asbestos. <br />R502.1.1.2 Heating and cooling systems. New heating, cooling and duct systems that are part of the addition shall <br />comply with Section R403. <br />Exception: The following need not comply with the testing requirements of Section R403.3.3: <br />1. Additions of less than 750 square feet. <br />2. Duct systems that are documented to have been previously sealed as confirmed through field <br />verification and diagnostic testing in accordance with procedures in WSU RS-33. <br />3. Ducts with less than 40 linear feet in unconditioned spaces. <br />4. Existing duct systems constructed, insulated or sealed with asbestos. <br />R503.1.3 Service hot water systems. New service hot water systems that are part of the alteration shall comply with <br />Section R403.5. <br />R503.1.4 Lighting. New lighting systems that are part of the alteration shall comply with Section R404.1. <br />Exception: Alterations that replace less than 50 percent of the luminaires in a space, provided that such <br />alterations do not increase the installed interior lighting power. <br />R503.2 Change in space conditioning. Any nonconditioned or low -energy space that is altered to become conditioned <br />space shall be required to be brought into full compliance with this code. <br />(Effective July 1, 2013.) <br />WAC 51-51-0325 <br />Section R325 - Adult family homes. <br />EXISTING ROOF FRAMING <br />LE)DININ(5 <br />1�. <br />EXISTING EXISTING EXI5TING <br />FOUNDATION CRAWL SPACE FLOOR FRAMING <br />nAE3UILUINO SECTION <br />SCALE: 1/4" = 1'-0" <br />SECTION R325 <br />ADULT FAMILY HOMES <br />R325.1 General. This section shall apply to all newly constructed adult family homes and all existing single family homes being <br />converted to adult family homes. This section shall not apply to those adult family homes licensed by the state of Washington <br />department of social and health services prior to July 1, 2001. <br />R325.2 Submittal standards. In addition to those requirements in Section 106.1, the submittal shall identify the project as a Group <br />R-3 Adult Family Home Occupancy. A floor plan shall be submitted identifying the means of egress and the components in the <br />means of egress such as stairs, ramps, platform lifts and elevators. The plans shall indicate the rooms used for clients and the <br />sleeping room classification of each room. <br />R325.3 Sleeping room classification. Each sleeping room in an adult family home shall be classified as: <br />1. Type S - Where the means of egress contains stairs, elevators or platform lifts. <br />2. Type NS1 - Where one means of egress is at grade level or a ramp constructed in accordance with R325.9 is provided. <br />3. Type NS2 - Where two means of egress are at grade level or ramps constructed in accordance with R325.9 are provided. <br />R325.4 Types of locking devices and door activation. All bedroom and bathroom doors shall be openable from the outside when <br />locked. <br />Every closet shall be readily openable from the inside. <br />Operable parts of door handles, pulls, latches, locks and other devices installed in adult family homes shalt be operable with one <br />hand and shall not require tight grasping, pinching or twisting of the wrist. Pocket doors shalt have graspable hardware available <br />when in the closed or open position. <br />The force required to activate operable parts shall be 5.0 pounds (22.2 N) maximum. Required exit doors shall have no additional <br />locking devices. <br />Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing reentry into the adult <br />family home without the use of a key, tool or special knowledge. <br />R325.5 Smoke and carbon monoxide alarm requirements. All adult family homes shall be equipped with smoke and carbon <br />monoxide alarms installed as required in Sections R314 and R315.1. Alarms shall be installed in such a manner so that the <br />detection device warning is audible from all areas of the dwelling upon activation of a single alarm. <br />R325.6 Escape windows and doors. Every sleeping room shall be provided with emergency escape and rescue windows as <br />required by Section R310. No alternatives to the sill height such as steps, raised platforms or other devices placed by the openings <br />will be approved as meeting this requirement. <br />R325.7 Fire apparatus access roads and water supply for fire protection. Adult family homes shall be served by fire apparatus <br />access roads and water supplies meeting the requirements of the local jurisdiction. <br />R325.8 Grab bar general requirements. Where facilities are designated for use by adult family home clients, grab bars for water <br />closets, bathtubs and shower stalls shall be installed according to this section. <br />R325.8.1 Grab bar cross section. Grab bars with a circular cross section shall have an outside diameter of 1 1/4 inches minimum <br />and 2 inches maximum. Grab bars with noncircular cross section shall have a cross section dimension of 2 inches maximum and a <br />perimeter dimension of 4 inches minimum and 4 5/8 inches maximum. <br />R325.8.2 Grab bar installation. Grab bars shall have a spacing of 1 1/2 inches between the wail and the bar. Projecting objects, <br />control valves and bathtub or shower stall enclosure features above, below and at the ends of the grab bar shall have a clear space <br />of 1 112 inches to the grab bar. <br />EXCEPTION: Swing -up grab bars shall not be required to meet the 1 112 inch spacing requirement. <br />Grabs bars shall have a structural strength of 250 pounds applied at any point on the grab bar, fastener, mounting device or <br />supporting structural member. Grab bars shall not be supported directly by any residential grade fiberglass bathing or showering <br />unit. Acrylic bars found in bathing units shall be removed. <br />Fixed position grab bars, when mounted, shall not rotate, spin or move and have a graspable surface finish. <br />LL <br />Z <br />C <br />t•- <br />Q <br />LL <br />9E <br />A <br />MIN <br />M <br />M <br />M <br />NEW INTERIOR WALL 1 11 PLATE @) MAIN <br />r � r <br />T®1\ l(E) w <br />t LOWER FLOOR <br />Q <br />FIN15H GRADE <br />EXI5TING / <br />FOUNDATION <br />R325.8.3 Grab bars at water closets. Water closets shall have grab bars mounted on both sides. Grab bars can be a combination <br />of fixed position and swing -up bars. Grab bars shall meet the requirements of R325.8. Grab bars shall mount between 33 inches <br />and 36 inches above floor grade. Centerline distance between grab bars, regardless of type used, shall be between 25 inches <br />minimum and 30 inches maximum. <br />R325.8.3.1 Fixed position grab bars. Fixed position grab bars shall be a minimum of 36 inches in length and start 12 inches from <br />the rear wall <br />R325.8.3.2 Swing -up grab bars. Swing -up grab bars shall be a minimum of 28 inches in length from the rear wall. <br />R325.8.4 Grab bars at bathtubs. Horizontal and vertical grab bars shall meet the requirements of R325.8. <br />R325.8.4.1 Vertical grab bars. Vertical grab bars shall be a minimum of 18 inches long and installed at the control end wall and <br />head end wall. Grab bars shall mount within 4 inches of the exterior of the bath tub edge or within 4 inches within the bath tub. The <br />bottom end of the bar shall start between 36 inches and 42 inches above floor grade. <br />EXCEPTION: The required vertical grab bar can be substituted with a floor to ceiling grab bar meeting the <br />requirements of R325.8 at the control end and head end entry points. <br />R325.8A.2 Horizontal: grab bars. Horizontal grab bars shall be provided at the control end, head end, and the back wall within the <br />bathtub area. Grab bars shall be mounted between 33 inches and 36 inches above floor grade. Control end and head end grab bars <br />shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. <br />R325.8.5 Grab bars at shower stalls. Where shower stalls are provided to meet the requirements for bathing facilities, grab bars <br />shall meet the requirements of R325.8. <br />EXCEPTION: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab <br />bars at the seat end wall. A vertical floor to ceiling grab bar shall be installed within 4 inches of <br />the exterior of the shower aligned with the nose of the built-in seat. <br />R325.8.5.1 Vertical grab bars. Vertical grab bars shall be 18 inches minimum in length and installed at the control end wall and <br />head end wall. Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower <br />stall. The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. <br />R325.8.5.2 Horizontal grab bars. Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 <br />inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent wails. Horizontal <br />grab bars shall not interfere with shower control valves. <br />R325.9 Ramps. All interior and exterior ramps, when provided, shall be constructed in accordance with Section R311.8 with a <br />maximum slope of 1 vertical to 12 horizontal. The exception to R311.8.1 is not allowed for adult family homes. Handrails shall be <br />installed in accordance with R325.9.1. <br />R325.9.1 Handralls for ramps. Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal <br />and 1 vertical and 20 horizontal in accordance with R311.6.3.1 through R311.6,3.3. <br />R325.10 Stair treads and risers. Stair treads and risers shall be constructed in accordance with R311.7.4. Handrails shall be <br />installed in accordance with R325.10.1. <br />R325�. �10.1 Handralls for treads and risers. Handrails shall be installed on both sides of treads and risers numbering from one riser <br />to multiple risers. Handrails shall be installed in accordance with R311.7.7 through R311.7.7.4. <br />R325.11 Shower stalls. Where provided to meet the requirements for bathing facilities, the minimum size of shower stalls for an <br />adult family home shall be 30 inches deep by 48 inches long. <br />( CE <br />25" MIN <br />30" MAX <br />Cn <br />15111 15" <br />30" MIN <br />001 <br />CLEAR-• <br />(R307.1) <br />F 16-vi <br />WMJI 11 <br />BATHTUB SHOWERTOILET <br />. ABAR REQUIREMENTS e ■ R325.8 INTERNATIONALRESIDENTIAL CODE <br />L� <br />a <br />Ai <br />I 1 1 1 1 EXTENDEXTEND6 BACKINk"j"SUIPP RT <br />1 I i 11 TO E T� TALL STUD <br />i� II �I 11 11 <br />1 1 "x /4 B1-%%J SHEET METAL <br />I i GRABBAR 32 <br />1I Ii 1I 11 1I <br />LAYOUT AND FASTENING <br />ATTAOHED GRAB BARS TO 5TUD5 OR 2X6 BLOCKING AND NOT TO GW5 5EOURELY� <br />FASTEN 2X6 BLOCKING TO 5TUD5 WITH TWO 50REW5 PER 5TUD5 AND A MINIMUM 6 j <br />50REW5 PER BOARD 1 <br />REVIEWEDF(_)R PERMIT <br />W <br />i <br />W <br />• <br />ii <br />U <br />O <br />f -- <br />z <br />oil, <br />2E <br />cl!:� 0 <br />O --J <br />U <br />70 <br />I <br />U_ <br />d) L L_ <br />� <br />U') <br />®J <br />U <br />®= <br />cl� <br />X0 <br />cl- <br />cl-Q <br />SHEET <br />
The URL can be used to link to this page
Your browser does not support the video tag.