View plain text
, -. • 410 • (3/D <br /> 11/18/2021 -___ <br /> ,k` -. Hod a Report # 210489A <br /> engineering inc. <br /> RE: 2207 Gibson Place Everett, WA <br /> Langus 3-Car Garage <br /> Plan Review 1 Engineering Response <br /> Table 4.2C Nominal Unit Shear Capacities for Wood-Frame Diaphragms <br /> Unblocked Wood Structural Panel Diaphragme.2,3- <br /> A B <br /> SEISMIC WINO <br /> Minimum 6 in.Nail Spacing at <br /> Minimum Minimum Nominal Width 8 in.Nail Spacing at diaphragm boundaries diaphragm boundaries and <br /> Common Fastener Nominal or Staged Face at and supported panel edges supported panel edges <br /> Sheathing Grade Penetration Panel Supported Cases <br /> sail Size in Framing Thickness Case 1 Cases 2,3,4,6,fi Case 2,3,4,5,6 <br /> (in.) {in.} )rlosV. G. vs G. v„ v„ <br /> 04 <br /> (pit) (kipalin,) (Pit) (kipsiin.) . (PN) _ (Pit) <br /> OSB PLY OSB PLY <br /> 8d 1-1/4 5/18 2 330 9.0 7.0 250 6.0 4.5 460 350 <br /> 370 7.0 6.0 280 4.5 4.0 520 390 <br /> Structural) 8d 14/8 3t8 2 480 8.5 7.0 360 6.0 4.5 670 505 <br /> 3 530 7.5 6.0 400 5.0 4.0 740 560 <br /> 10d 1-1/2 15/32 2 570 14 10 430 9.5 7.0 800 600 <br /> 3 640 12 9.0 480 8.0 6.0 895 670 <br /> 5/16 2 300 9.0 6.5 220 6.0 4.0 420 310 <br /> 8d 1-1/4 3 340 7.0 5.5 250 5.0 3.5 475 350 <br /> 2 330 7.5 5.5 250 5.0 4.0 460 350 <br /> 3/8 3 370 6.0 4.5 280 4.0 3.0 520 390 <br /> 2 430 9.0 6.5 320 6.0 4.5 600 450 <br /> 3/8 3 489 7 6 360 5.0 3.5 67 505 <br /> Sheathing and 2 460 8.5 8� 344 5.5 4.0 64 475 <br /> Single Floor 1-318 7/16 32 510 7.0 5.5 380 4.5 3.5 7t5 530 <br /> 15/32 2 4au (.0 S.0 360 5.0 4.0 u 505 <br /> 3 530 6.5 5.0 40Q 4.0 3.5 740 560 • <br /> 15132 2 510 15 9.0 380 10 6.0 715 530 <br /> tOd 1-1/2 3 580 12 8,0 430 8.0 5.5 810 600 <br /> 19/32 2 570 13 8.5 430 8.5 5.5 800 600 <br /> 3 840 10 7.5 480 7.0 5.0 895 670 <br /> 4. See overturning values of Page 9 of the structural calculations. It appears that uplift forces <br /> occur at multiple shear wall end locations. Hold downs should be provided to resist uplift forces <br /> caused by overturning effects by lateral forces, see IBC 1604.4 and 2018 SDPWS 4.3.6.4.4. <br /> The uplift forces provided by the lateral modeling program does not incorporate the structure's <br /> deadload. For example, header R7 has support loads of 1138 pounds. The dead loads at the <br /> corners of the building include wall and truss dead loads. The dead loads adequately resist <br /> uplift forces where holdowns are not specified. <br /> 5. The "Site Criteria"on Sheet S1 and calculations specifies a wind exposure factor of"B': The <br /> project site is located adjacent to open water. The design should be revised to exposure "D': <br /> Revised calculations substantiating the design should be submitted for review as needed. See <br /> IBC Section 1609.1 and ASCE 7-16 Sections 26.7.2 and 26.7.3 <br /> The engineering has been revised to wind exposure factor"D". <br /> 6. Wind speed(Gust)should be updated to 85 mph per EMC Section 16.01.010(J). This results <br /> in an ultimate design wind speed of 110 mph per Table R301.2.1.3. Plans and calculations <br /> should be updated i ' ''i-- '4 " t <br /> Later ineennecorn.s ed to the 2018 IBC which follows the ASCE7-16 wind speed <br /> ma pail et ods� . 'ultima design wind speed of the IRC and IBC are different even <br /> thb g Moth re: ren SCE,7-16. The 2018 IRC did not adopt the ASCE 7-16 wind <br /> 1apsO,r meth��•s and sti -ses the ASCE7-10 wind methods. The IRC methods needs to <br /> �b <br /> i y i4i ! , , Hodge Engineering, Inc. <br /> 062, S, ,0 1111 hNl lP' <br /> �, V�I;N111�,' "` John E.Hodge P.E. <br /> la ,. u <br /> 6 , i�i d 3733 Rosedale St NW,Suite 200,Gig Harbor, WA 98335 <br /> !ii'', �''00. (253)857-7055 <br />
The URL can be used to link to this page
Your browser does not support the video tag.