2207 GIBSON PL 2022-10-28
>
Address Records
>
GIBSON PL
>
2207
>
2207 GIBSON PL 2022-10-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2022 9:35:15 AM
Creation date
10/28/2022 9:33:44 AM
Metadata
Fields
Template:
Address Document
Street Name
GIBSON PL
Street Number
2207
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> August 18,2014 <br /> Gibson Bluff <br /> L&A Job No. 14-056 <br /> Page 13 • <br /> Building Foundations <br /> Conventional footing foundations may be used to support the proposed residences. The <br /> footing foundations should be constructed on or into the underlying undisturbed, medium- <br /> dense to dense, Esperance sand soil. Water should not be allowed to accumulate in <br /> excavated areas of footing foundations or on-grade slabs. Disturbed and saturated soils in <br /> footing trenches or under on-grade slabs should be completely removed down to firm <br /> undisturbed Esperance sand soil prior to pouring'concrete for the footings and floor slabs. <br /> Exposed footing bearing soil should be compacted to a non-yielding state with a vibratory <br /> mechanical compactor prior to pouring concrete for footing foundations. <br /> If the above recommendations are followed, our recommended design criteria for footing <br /> foundations are as follows: <br /> • Allowable soil bearing pressure for footing foundations, including dead and live <br /> loads, should not exceed 3,000 psf. Footing bearing soil should be verified by a <br /> geotechnical engineer prior to pouring concrete for footing foundations. <br /> • The minimum depth to bottom of perimeter footings below adjacent final exterior <br /> grade should be no less than 18 inches. The minimum depth to bottom of the <br /> interior footings below top of floor slab should be no less than 12 inches. <br /> • The minimum width should be no less than 18 inches for continuous footings, and <br /> no less than 24 inches for individual footings, except those footings supporting <br /> light-weight porches and wood decks. <br /> A one-third increase in the above recommended allowable soil bearing pressure may be <br /> used when considering short-term, transitory, wind or seismic loads. For the buildings <br /> LIU & ASSOCIATES, INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.