My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1033 51ST PL SW Geotech Report 2022-10-28
>
Address Records
>
51ST PL SW
>
1033
>
Geotech Report
>
1033 51ST PL SW Geotech Report 2022-10-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2022 4:25:56 PM
Creation date
10/28/2022 4:24:29 PM
Metadata
Fields
Template:
Address Document
Street Name
51ST PL SW
Street Number
1033
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
9.6 GEOTEXTILES <br /> 9.6.1 Separation and Drainage Geotextile <br /> We recommend using a non-woven geotextile drainage material around subsurface drains to <br /> separate drain rock from adjacent materials. The geotextile should conform to the specifications <br /> for non-woven separation material provided In WSS 9-33.2(1)-Geotextile Properties, Table 3 <br /> Geotextile for Separation or Soil Stabilization,similar to Mirafi 160N. <br /> • <br /> 10.0 OBSERVATION OF CONSTRUCTION <br /> Recommendations provided in this report assume that GeoDesign will be retained to provide <br /> geotechnicai consultation and observation services during construction. Satisfactory earthwork <br /> and foundation performance depends to a large degree on the quality of construction. <br /> Subsurface conditions observed during construction should be compared with those. : <br /> encountered during the subsurface explorations. Recognition of changed conditions requires <br /> experience with the site conditions and an understanding of the geotechnical recommendations; <br /> therefore, GeoDesign personnel should visit the site with sufficient frequency to detect whether <br /> subsurface conditions change significantly from those anticipated and to verify that the work is <br /> completed in accordance with the construction drawings and specifications. <br /> Sufficient observation of the contractor's activities is a key part of determining that the work is <br /> completed in accordance with the construction drawings, project specifications, and our <br /> recommendations. <br /> We recommend that GeoDesign be retained to observe all earthwork activities, including the <br /> following: <br /> • -Excavation,activities <br /> • • Subgrade preparation prior to fill placement or foundation construction <br /> • Verification of foundation subgrades <br /> • Placement and compaction of fill, including fill placed in utility trenches and around buried <br /> structures <br /> • Laboratory compaction and field moisture-density tests <br /> 11.0 LIMITATIONS <br /> We have prepared this report for use by NW Homefinders, Inc.and the design and construction <br /> team for the proposed development. The data and report can be used for bidding or estimating <br /> purposes, but our report, conclusions,and interpretations should not be construed as warranty <br /> of the subsurface conditions and are not applicable to other sites. <br /> 'Exploration Obsenrations"indicate'soil conditions only at specific locations and only to the depths <br /> penetrated. They do not necessarily reflect soil strata or water level variations that may exist <br /> between exploration locations. If subsurface conditions differing from those described are noted <br /> during excavation and construction, re-evaluation will be necessary. <br /> GEODESIGNY 14 NWHame-1-n1:10161 R <br />