My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1035 51ST PL SW Geotech Report 2022-10-31
>
Address Records
>
51ST PL SW
>
1035
>
Geotech Report
>
1035 51ST PL SW Geotech Report 2022-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2022 10:44:44 AM
Creation date
10/31/2022 10:43:14 AM
Metadata
Fields
Template:
Address Document
Street Name
51ST PL SW
Street Number
1035
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e e <br /> element to help evaluate soil capacity for water quality treatment. The CEC tests and organic <br /> content tests were performed by AMTest Laboratories. A summary of the test results is provided <br /> in Table 2. <br /> Tablet. CEC and Organic Content Analytical Results Summary' <br /> Sample Organic <br /> CEC <br /> Exploration Depth Soil Type Content • <br /> (meq per 100 grams) (percent) <br /> • (feet BGS) <br /> Silty Sand with 8.9 2.8 <br /> TP-5 2.0 gravel T- Fill <br /> 1. Suitability for Water Quality Treatment: CEC greater than 5 meq per 100 grams and organic content a minimum of <br /> 1.0 percent(DOE,2012) <br /> The full analytical laboratory test report of the CEC and organic content test results is presented <br /> in Appendix B. <br /> 7.0 DESIGN <br /> Based on our review of the proposed preliminary development plans and the results of our <br /> explorations and analyses, it is our opinion that the proposed development can be constructed at <br /> the site. Our recommendations are provided in the following sections. <br /> 7.1 SEISMIC DESIGN CRITERIA <br /> 7.1.1 IBC Parameters <br /> Based on our explorations and analysis,the following design parameters can be applied if the <br /> structures are designed using the applicable provisions-of the 2015 IBC. The parameters in <br /> Table 2 should be used to compute seismic base shear forces (IBC, 2015). <br /> Table 2. IBC Seismic Design Parameters • <br /> Parameter Short Period 1 Second <br /> MCE Spectral Acceleration S,= 1.422 g S, =0.540 g <br /> • • Site Class • D <br /> • <br /> Site Coefficient Fa= 1.0 FF= 1.5 <br /> Adjusted Spectral Acceleration SMs 1.422 g SM, =0.810 g <br /> Design Spectral Response Acceleration Parameters Sc,s=0.948 g So, =0.540 g <br /> G EO DESIGN= 4 NWHome-1-01:101618 <br />
The URL can be used to link to this page
Your browser does not support the video tag.