My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1415 52ND ST SE EVERETT STAR ADULT FAMILY HOME 2022-10-31
>
Address Records
>
52ND ST SE
>
1415
>
EVERETT STAR ADULT FAMILY HOME
>
1415 52ND ST SE EVERETT STAR ADULT FAMILY HOME 2022-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2022 10:53:01 AM
Creation date
10/31/2022 10:52:29 AM
Metadata
Fields
Template:
Address Document
Street Name
52ND ST SE
Street Number
1415
Tenant Name
EVERETT STAR ADULT FAMILY HOME
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• I <br /> " ' F 2018 Washington State Energy Code—Residential <br /> Prescriptive Energy Code Compliance for All Climate Zones in Washington <br /> Single Family—New&Additions(effective February 1,2021) Version 1.0 <br /> These requirements apply to all IRC building types, including detached one- and two-family <br /> dwellings and multiple single-family dwellings (townhouses). <br /> Project Information Contact Information <br /> Halima AFH Martin Reimers <br /> 1415 52nd St, Everett, WA 98203 -_ Imreimers@conceptarchitecture.com <br /> Instructions:This single-family project will use the requirements of the Prescriptive Path below and <br /> incorporate the minimum values listed. Based on the size of the structure,the appropriate number of <br /> additional credits are checked as chosen by the permit applicant. <br /> Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and <br /> Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits. <br /> Martin Reimers a9"aa°r"a°'°a°'m°0 <br /> Authorized Representative Data 202112021 225-°`° "`"" "' ° Date 12/02/2021 <br /> Data 2021.12.02 13.52.25-0803' <br /> All Climate Zones(Table R402.1.1) <br /> R-Value a U-Factor a <br /> Fenestration U-Factor b n/a 0.30 <br /> Skylight U-Factor b n/a 0.50 <br /> Glazed Fenestration SHGC bje n/a n/a <br /> Ceiling e 49 0.026 <br /> Wood Frame Wall g.h 21 int 0.056 <br /> Floor 30 0.029 <br /> Below Grade Wall c,h 10/15/21 int+TB 0.042 <br /> Slab"R-Value& Depth 10, 2 ft n/a <br /> R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity that is less <br /> a than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix <br /> Table A101.4 shall not be less than the R-value specified in the table. <br /> b The fenestration U-factor column excludes skylights. <br /> "10/15/21+5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on <br /> the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at <br /> c the interior of the basement wall. "10/15/21+5TB" shall be permitted to be met with R-13 cavity insulation on <br /> the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" <br /> means R-5 thermal break between floor slab and basement wall. <br /> d R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. <br /> For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth <br /> e extends over the top plate of the exterior wall. <br /> R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter <br /> f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall <br /> meet the requirements for thermal barriers protecting foam plastics. <br /> For log structures developed in with Standard ICC 400, log walls shall meet the requirements for <br /> g climate zone 5 of ICC 400. <br /> Int. (intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard <br /> h framing 16 inches on center, 78%of the wall cavity insulated and headers insulated with a minimum of R-10 <br /> insulation. <br /> Prescriptive Path—Single Family 2018 Washington State Energy Code-R 1 . '� <br />
The URL can be used to link to this page
Your browser does not support the video tag.