My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1029 52ND ST SW 2022-10-31
>
Address Records
>
52ND ST SW
>
1029
>
1029 52ND ST SW 2022-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2022 12:12:26 PM
Creation date
10/31/2022 12:01:23 PM
Metadata
Fields
Template:
Address Document
Street Name
52ND ST SW
Street Number
1029
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
180
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
o <br /> 4.4 SEISMICITY <br /> 4.4.1 General <br /> Washington State is situated at a convergent continental margin and is susceptible to subduction <br /> zone, intraplate, and shallow crustal source earthquakes. We reviewed published geologic maps <br /> for the sitevicinity•to evaluate,seismic activity hazard areas.The site is approximately 1.6 miles <br /> east of the north border of the Southern Whidbey Island fault zone(DNR, 2018). <br /> 4.4.2 Geologic Hazards <br /> The site is generally gently sloping and is underlain at shallow depths by dense to very dense <br /> glacial till. Risks associated with landslide hazards,slope stability, liquefaction, lateral spreading, <br /> or surficial rupture are low`for'this site. Based on the topography, there are no slopes on site <br /> that meet the City Land Use Code Chapter 19.37.080 definition for Geologically Hazard Areas on <br /> or adjacent to the site. <br /> 5.0 INFILTRATION TESTING <br /> Small-scale PITs were performed at two of the test pit locations in general accordance with the <br /> 2014 Stormwater Management Manual for Western Washington (DOE, 2014). The test pits were <br /> generally rectangular and approximately 3 feet wide by 5 feet long. The PIT was performed near <br /> the anticipated bottom of infiltration elements at a depth of 1.5 feet BGS. Soil conditions <br /> encountered at the base of the infiltration test consisted of a silty sand with gravel fill material. <br /> An electronic pressure transducer and data logger were placed in each test pit to measure <br /> groundwater levels at regularshort-term'intervals throughout the saturation period and during <br /> the tests. The tests were repeated as time and the infiltration rate permitted. Up to <br /> approximately 12 to 18 inches of water was established in each test pit during the tests. The <br /> infiltration rate measurednear the.end of each test,which allows for the longest saturation <br /> period, is used to calculate the short-term infiltration rate, as summarized in Table 1. <br /> Table]. Soil Infiltration Rate Analysis <br /> Averaged Measured <br /> Test Short-Term <br /> Infiltration Soil Type Depth <br /> Location Infiltration Rate <br /> (feet (inches per hour) <br /> Medium dense, silty Sand 1.5 6.0 <br /> TP-3 with gravel - Fill <br /> Medium dense, silty Sand 1.5 3.7 <br /> TP-5 with gravel-Fill <br /> 6.0 LABORATORY'TESTING <br /> Laboratory testing was conducted on specific soil samples collected from the explorations to <br /> assist in the characterization of certain physical parameters of the soil. CEC and organic content <br /> tests were completed on samples collected at or near the anticipated base of the LID infiltration <br /> C�DESIGN3 3 NWHome-1-01:1 01618 <br />
The URL can be used to link to this page
Your browser does not support the video tag.