My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Jacobs Engineering Inc. 11/3/2022 Amendment 1
>
Contracts
>
Agreement
>
Professional Services (PSA)
>
Jacobs Engineering Inc. 11/3/2022 Amendment 1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 10:25:50 AM
Creation date
11/10/2022 10:24:31 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Jacobs Engineering Inc.
Approval Date
11/3/2022
Council Approval Date
2/3/2021
End Date
12/31/2026
Department
Public Works
Department Project Manager
Candice Au-Yeung
Subject / Project Title
CSO Storage at 36th ST Detailed Design
Amendment/Change Order
Amendment
Amendment/Change Order Number
1
Tracking Number
0002775
Total Compensation
$2,814,996.00
Contract Type
Agreement
Contract Subtype
Professional Services
Retention Period
6 Years Then Destroy
Imported from EPIC
No
Document Relationships
Jacobs Engineering Group Inc. 2/8/2021
(Amendment)
Path:
\Records\City Clerk\Contracts\6 Years Then Destroy\2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
the upstream and downstream collection system functions without sanitary sewer overflows, while <br /> achieving CSO compliance at SR07 and SR08 by the year 2027. <br /> This amendment consists of detailed design and bidding period support services for Alternative 4, as <br /> defined in Technical Memorandum, Task 270—Alternatives Development and Analysis, prepared by <br /> Jacobs (Consultant) in January 2022.The Project will generally consist of: <br /> • A new 1.8 million gallon (MG) underground cast-in-place CSO storage tank,with associated new <br /> electrical, instrumentation & controls, mechanical, and civil/structural work elements at the <br /> City-owned property north of 36th Street and just south of the Everett Station Park and Ride Lot <br /> B (parcel#29052900201200). <br /> • Modifications to its existing combined sewer(CS) system to include: <br /> o Modifications to the existing 36th Street regulator structure that would provide a means <br /> for diverting combined sewer flows to the new CSO tank. <br /> o Modifications to the existing Pacific Regulator that would provide a means for diverting <br /> combined sewer flows to a new approximately 48-inch diameter pipe along Pacific Ave. <br /> • Installation of approximately 1,000 LF of sewer pipe along Pacific Avenue to increase sewer <br /> capacity(install new parallel pipe or replace and upsize existing pipe). <br /> 2. ASSUMPTIONS FOR AMENDMENT NO. 1 <br /> This scope of work is based on the following assumptions: <br /> • This project includes a comprehensive detailed design effort; however,for bid assistance,the <br /> Consultant will have a minor supporting role only. <br /> • Budget for the project scope for detailed design through bidding is based on a project schedule <br /> of 20 months, commencing with notice-to-proceed in November 2022. Bidding period support <br /> services is subject to the level of effort requested by the City and budget allocated. <br /> • Deliverables will be in electronic format,with exception of bid set documents. <br /> • Meetings will be held virtually. <br /> • The Consultant may shift budget between work tasks in order to adjust for differences in scope <br /> or level of effort—planned versus actual with approval of City's Project Manager. Consultant <br /> will discuss any proposed budget adjustments with the City in advance. <br /> • The City will provide certain documents including, but not limited to,the list in Section 3. <br /> • The City's CAD Standards will be used. <br /> • Design and Standard Specifications and Details shall utilize: <br /> o City of Everett's Design and Construction Standards. <br /> o The City's master specifications and applicable additional provisions to the Standard <br /> Specifications. <br /> o Consultant standard specifications in 2004 CSI format. <br /> o Additional design references as may be furnished by the City such as examples from <br /> previous projects. <br /> • All City-supplied information/ references will be provided to the Consultant within two weeks of <br /> Notice to Proceed on this Amendment. <br /> April 2022 Page 2 of 35 Jacobs Engineering Group <br />
The URL can be used to link to this page