Laserfiche WebLink
t 4. <br /> Interior Lighting - Spas \-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised July 2016 <br /> Project Title: KFC-Everett Date 10/10/2019 <br /> Calculation 0 0 Addition- 0 Addition For Building Department Use <br /> Area NOTE 9 stand alone +existing <br /> 0 Spaces where<50%of ® Spaces where t 50%of 0 <br /> luminaires are replaced luminaires are replaced <br /> LPA ® Standard 0 Additional Efficiency Package Option 0 <br /> CalculationC406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE' <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> A202 Dining area:Family dining area 9 1455 0.710 1033 <br /> A202 Restroom:all other 8 43 0.780 34 <br /> A202 Restroom:all other 8 43 0.780 34 <br /> Total Area 1541 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 1101 <br /> Proposed Lighting Wattage NOTE 3 <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 Proposed <br /> A202 LO1 Pendant 1 150 150 <br /> A202 L02 Glass Pendant 8 3 24 <br /> A202 L03 6"Recessed Can 26 14 364 <br /> A202 L04 4"LED Downlight 6 9 54 <br /> A202 L05 3"Recessed 2 8 16 <br /> A202 LO6 1 x 4 LED 2 37 74 <br /> A202 L07 2 x 4 LED 2 50 100 <br /> A202 TO1 LED Wall Washer 2 35 70 <br /> A202 T02 Track Light 12 9 108 <br /> A202 EM01 Exit Sign 2 3 5 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 965 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> liahtino systems to demonstrate compliance.Refer to C502.1. <br /> , 117 <br />