My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
33 SE EVERETT MALL WAY 2022-11-16
>
Address Records
>
SE EVERETT MALL WAY
>
33
>
33 SE EVERETT MALL WAY 2022-11-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2022 1:42:57 PM
Creation date
11/16/2022 1:42:47 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
33
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting Summary, cor>,c. LTG-SUM <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised Nov 2017 <br /> Project Title: Sound Credit Union-Everett Date 1/1/2017 <br /> Change of Space Use ❑ Existing interior lighting systems in areas under-going a change in space use are upgraded to <br /> comply with LPAs for the new space types per Tables C405.4.2(1)or C405.4.2(2). <br /> Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in <br /> LTG-INT-BLD or LTG-INT-SPACE form. <br /> Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting <br /> Lighting Alterations 50%or more of existing are replaced ❑ ❑ ❑ <br /> Select all Lighting Power and Lighting <br /> Control elements that apply to the scope Less than 50%of existing are replaced ❑ ❑ ❑ <br /> of the retrofit project.If project includes a <br /> combination of spaces where less than Lamp and/or ballast replacement only ❑ ❑ El <br /> of the existing fixtures are replaced in -existing total wattage not increased <br /> some spaces,and 50%or more of the 50%or more replaced-Total lighting power of new+existing-to-remain fixtures shall comply with total <br /> fixtures are replaced in others,then LPA per Sections C405.4.2 and C405.5.2. Include new+existing-to-remain fixtures in Proposed <br /> provide separate lighting power Lighting Wattage table in LTG-INT-BLD,LTG-INT-SPACE or LTG-EXT form. <br /> compliance forms for the two retrofit <br /> conditions.Spaces undergoing the same Less than 50%replaced-Total lighting power of new+existing-to-remain fixtures shall not exceed the <br /> type of retrofit may be combined into one total lighting power prior to alteration. Include new+existing-to-remain fixtures in the Proposed Lighting <br /> lighting power compliance form. Wattage table in LTG-INT-BLD,LTG-INT-SPACE or LTG-EXT form. <br /> 50%threshold applies to number of luminaires for interior spaces and parking garages,and total <br /> Refer to Section C503.6 for additional installed wattage for exterior luminaires. <br /> requirements. Lighting Controls Interior lighting Parking 9 g g garage Exterior lighting <br /> All alteration lighting controls shall be New wiring installed to serve added <br /> commissioned per C408.3. fixtures and/or fixtures relocated to new ❑ ❑ ❑ <br /> circuit(s) <br /> New or moved lighting panel ❑ ❑ ❑ <br /> Interior space is reconfigured <br /> CI <br /> luminaires unchanged or relocated only - <br /> New wiring or circuit-For interior lighting,provide required manual controls per C405.2.3,occupancy <br /> sensor controls per C405.2.1,daylight responsive controls per C405.2.4 and application specific lighting <br /> El No changes are being made to controls per C405.2.5.For exterior lighting,provide required controls per C405.2.7. <br /> the interior or exterior lighting New or moved panel-Provide all applicable lighting controls as noted for New Wiring and automatic <br /> systems and existing space time switch controls per C405.2.2. <br /> uses and configuration are not Reconfigured interior space-Provide all required lighting controls that apply to a new interior space. <br /> changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. <br /> zi 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.