My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3102 ROCKEFELLER AVE CANFIELD MADOW LAW GROUP 2022-11-28
>
Address Records
>
ROCKEFELLER AVE
>
3102
>
CANFIELD MADOW LAW GROUP
>
3102 ROCKEFELLER AVE CANFIELD MADOW LAW GROUP 2022-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2022 11:50:58 AM
Creation date
11/18/2022 2:41:59 PM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
3102
Tenant Name
CANFIELD MADOW LAW GROUP
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> Capital Architects Group P pc <br /> 2813 Rockefeller Ave. Everett,WA 98201•ph:425.317.8017•fax:425.317.8489 <br /> 7 , <br /> 12.02.2019 a� <br /> City of Everett, Permit Services )— 7 <br /> 3200 Cedar Street 1 ; 's`.; 2 <br /> Everett,WA 98201 L, <3 a � <br /> Attention:Tony Lee Per. " ''; ETT <br /> urvices <br /> RE: Plan Check Number B1909-028, RECHECK#1 <br /> Owner: Rockefeller Building LLC <br /> Job Address: 3102 Rockefeller Avenue <br /> Tony, <br /> Thank you for your review comments. Please note our written responses for each item below: <br /> 1) As concluded in my previous email's,the basement is newly created habitable and occupiable space per IBC Definition <br /> Section 202.IEBC Section 801.3 Exception 4 requires the basement to have a minimum of 7 feet of ceiling height.As the new <br /> uses proposed are not offices but are spaces with intermittent use(conference and fitness room)I am not opposed to using <br /> the similar provisions of IPMC Section 404.3 Exception 2 that would permit this basement to have a minimum ceiling height <br /> of 6 foot 8 inches with a minimum clear height of 6 foot 4 inches under beams,girders,ducts and similar obstructions. <br /> a. If the flush beam w/post replacement detail 1/SS-1 is to be included in this scope of work(email attachment)please <br /> include the detail on the plans. <br /> Response: The flush beam with post replacement detail is included in this scope of work. We have added this detail <br /> to sheet A-2.3. <br /> 2) All of the toilet rooms are being altered from their existing configurations.All new construction elements,components, <br /> systems and spaces should comply with the requirements of the IBC per IEBC Section 801.3: <br /> a.All toilet rooms are required to be accessible.IBC Section 1109.2 <br /> b.If a shower will be provided in the basement,an additional shower should also be provided on the main floor.IBC Section <br /> 1109.2 <br /> Response: The shower has been removed in the basement. <br /> 3)The automatic fire detection and fire suppression system EMC Chapter 16.76 applies to new construction,changes of <br /> occupancy and existing buildings.In 1989 the building underwent a change of occupancy from R-3 to Group B-2 which <br /> included the(non-habitable)basement area approved for storage use(permit 21665).This proposal is for a change of use of <br /> the basement from non-habitable storage to habitable space-which is a change of use,however not a change of occupancy. <br /> Therefore,a fire alarm is not required. <br /> Response: Per your comment above,a Fire Alarm will not be provided on this project. <br /> 4) The code defines a primary function in Definition Section 202.Per that definition,the majority of the spaces, <br /> including office spaces would be defined as primary function areas.The work of creating accessible toilet rooms will <br /> more than satisfy IEBC Section 705.2,however. <br /> Response: So Noted. <br /> Sincerely, <br /> UP <br /> Sandra ins <br /> President <br /> Capital Architects Group Pc <br /> 1 I Page <br />
The URL can be used to link to this page
Your browser does not support the video tag.