2709 22ND ST 2022 Plans 2024-11-26
>
Address Records
>
22ND ST
>
2709
>
Plans
>
2709 22ND ST 2022 Plans 2024-11-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2024 10:46:53 AM
Creation date
12/1/2022 9:01:40 AM
Metadata
Fields
Template:
Address Document
Street Name
22ND ST
Street Number
2709
Permit
B2209-058
Year
2022
Notes
NEW 6' x 10' COVERED PORCH ON S FACE / FRONT DOOR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N <br /> �MyBuildingPermit.com <br /> a service of eCityGov.net Construction Tip Sheet 05 <br /> Guards & Attachment <br /> Guards are required when the deck is more than 30 inches above grade.) (,,, -- (0 <br /> �—- 2x2 Baluster, typical <br /> ! . 6'-0" max. spacing 7/� 2x6 or 5/4 board ail cap: attach <br /> r to guard post with (3)#12 by 3" <br /> — — — — : j:I I: I long screws or (3) 16d threaded <br /> nails with 0.148 nominal <br /> diameter <br /> 2x4 top and bottom; attach to <br /> guard post with (2) 8d threaded <br /> nails or (2) #8 wood screws <br /> >_ 2 1/2" long on inside face <br /> ~,:� I• :�:E : : : + ••,". -- 4x4 guard post, typical <br /> Do Not Notch <br /> I <br /> — 2 x 8 nominal rim or outside <br /> / joist. minimum <br /> T< 2 5/8" diameter Openings shall Attach balusters at top and bottom with <br /> through-bolts not allow the (1)#8 wood screw or (2) 8d post-frame <br /> and washers passage of a 4" threated nails with 0.135 nominal <br /> diameter sphere diameter <br /> ' tfi" 4x4 min. post <br /> max I A <br /> ii 5/8"p.D.galvanized bolt @ 6'0•'o.c.max., Typ <br /> 11 or threaded rod w/ <br /> fit. nuts&washers mn <br /> f min and 5"may '� <br /> 1111 <br /> ;!.. <br /> 2 �1 z <br /> 16 ��. <br /> m Min. 1800# <br /> _�_cill tension device Section A <br /> 1 , i� �� <br /> -_ IAn 5/8'O.D.galvanized bolt <br /> or threaded rod w/ <br /> �� 2x8 min.blocking <br /> B —P nuts&washers <br /> =� r 2'mhi <br /> �r, <br /> 2x8 min.deck 2-min 1ri ��. ' <br /> joists& rims 2/'min and 5"max { f <br /> / T'min 1I� , ft <br /> Note: 1111‘ <br /> Use above details for guard connections or provide engineered Min. 1800#tension straps <br /> design that shows Guards can resist a single concentrated load <br /> of 200 fb5 applied in any direction at any point along the top and Section B <br /> have attachment devices and supporting structure to transfer this <br /> load to appropriate structural elements of the building per IBC <br /> sec 1607.7.1.1 <br /> January 14,2022 MyBuildingPermit.com I Basic Deck <br /> eCityGov.net <br /> 2005;•CitrGrn•4ikanx <br />
The URL can be used to link to this page
Your browser does not support the video tag.