Laserfiche WebLink
GENERAL RESIDENTIAL CODE NOTES <br />2015 INTERNATIONAL RESIDENTIAL CODEJ <br />1. NATURAL LIGHT SHALL BE PROVIDED IN HABITABLE ROOMS BY AGGREGATE GLAZING <br />AREA OF NOT LESS THAN 8% OF THE FLOOR AREA OF SUCH ROOMS PER IRC R303.1 <br />2. NATURAL VENTILATION SHALL BE PROVIDED IN HABITABLE ROOMS BY APPROVED EXTERIOR <br />OPENINGS OF NOT LESS THAN 4% OF THE FLOOR AREA OF SUCH ROOMS PER IRC R303.1 <br />3. HABITABLE SPACE, HALLWAYS, BATHROOMS TOILET ROOMS, LAUNDRY ROOMS AND PORTIONS OF <br />BASEMENTS CONTAINING THESE SPACES SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN T-0" <br />BATHROOMS SHALL HAVE A MIN. CEILING HEIGHT OF 6-8" OVER FIXTURES R305.1 <br />4. BATHTUBS AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN <br />SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES <br />SHALL EXTEND TO A HEIGHT OF NOT LESS THAN V-0" ABOVE THE FLOOR <br />5. OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH DOORS IN ACCORDANCE <br />WITH AND SHALL BE SELF -CLOSING AND SELF -LATCHING PER IRC R309.1 <br />7. GARAGE - R SHALL BE SLOPED TO FACILITATE MOVEMENT O-LIQUIDS O DRAIN O, THE MAIN <br />VEHICLE ENTRY PER R309.2 <br />8. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND SOFFITS <br />PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD <br />9. STAIR RISER HEIGHT SHALL BE 4" min - 7-3/4" max. MINIMUM STAIR TREAD DEPTH SHALL BE 10". <br />NOSINGS OF 3/4" MIN. AND 1-1/4 MAX. SHALL BE PROVIDED WHERE TREADS ARE LESS THAN 11" (ON SOLID <br />STAIRWAYS) PER IRC R311.7.5.1 <br />10.. PROTECTION AGAINST DECAY, r .. FOR PRESSURE E . - is AND i -: RETARDE11T <br />TREATED HOT-DIPPEDZINC COATED GALVANIZED STEEL, STAINLESS <br />BRONZE <br />OR COPPER PER . - <br />11. LOCKS AT EXTERIOR SWING DOORS SHALL BE OPENABLE FROM THE INTERIOR SIDE BY A DEVICE WHICH <br />DOES NOT REQUIRE SPECIAL KNOWLEDGE OR EFFORT TO OPERATE. <br />12. THE DIAMETER OF THE EXHAUST DUCT SHALL BE AS REQUIRED BY THE MANUFACTURER ORA 4" DIAMETER <br />EXHAUST DUCT REQUIRED IF MANUFACTURER IS NOT KNOWN. THE MAX. LENGTH OF A CLOTHES DRYER <br />EXHAUST DUCT SHALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE WALL OR ROOF <br />TERMINATION. THE MAX. LENGTH OF DUCT SHALL BE REDUCE 2-1/2 FEET R <br />EACH 45 DEGREE BEND AND <br />EXCEPTIONS:5 FEET FOR EACH 90 DEGREE BEND. THE MAX. LENGTH OF THE DUCT DOES NOT INCLUDE THE TRANSITION <br />r FAN MAY .E INSTALLED PER a <br />• MODEL CLOTHESDRYER IS KNOWNAND SUBMITTED TO THE BUILDING OFFICIAL, THE MAX. <br />LENGTH OF THE DUCT MAY BE IN ACCORDANCE WITH THE DRYER MANUFACTURER'S INSTALLATION <br />INSTRUCTIONS. (3) WHEN THE DRYER MANUFACTURER IS NOT KNOWN, THE INSTALLED LENGTH AND <br />NUMBER OF ELBOWS SHALL BE POSTED IN A CONSPICUOUS LOCATION. A PLAQUE (MIN. 3" X 4") SHALL BE <br />AFFIXED ON THE WALL NEAR THE DUCT OUTLET THAT STATES "WARNING DO NOT REMOVE. TO AVOID THE <br />RISK OF FIRE CAUSED BY LINT BUILD PER IRC MI 501.2 & MI 501.3 WITH PIERCE COUNTY AMENDMENTS <br />NOTES <br />WASHINGTON STATE ENERGY CODE <br />OPTIONS SELECTED: TABLE 406.2 <br />ENERGY CREDITS <br />OPTION 1A a .5 CREDITS <br />EFFICIENT BUILDING ENVELOPE 1A: <br />PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE R402.1.1 WITH THE FOLLOWING MODIFICATIONS: <br />*VERTICAL FENESTRATION U = 0.23 <br />*FLOOR R-33 <br />SLAB ON GRADE R-10 PERIMETER AND UNDER ENTIRE SLAB <br />BELOW GRADE SLAB R-10 PERIMETER AND UNDER ENTIRE SLAB <br />OR <br />COMPLIANCE BASED ON SECTION R402.1.4: REDUCE THE TOTAL UA BY 5%. <br />OPTION 3B = 1 _CREDIT <br />z • <br />III <br />ELECTRIC <br />iT WITH INTERMITTENT HOUSE- b •, <br />1. TO BE SIZED ACCORDING TO IMC TABLE 403.8.5.2 <br />_%J�391W10-IM-0 A MINIMUM OF R-4 UNCONDITIONED SPACES, AND SEALED PER IRC SECTION 1601.4-1: <br />3. TERMINATE OUTSIDE BUILDING <br />4. BE EQUIPPED WITH A BACK -DRAFT DAMPER <br />GARAGE NOTES <br />1. GARAGE WALLS, COLUMNS, AND CEILINGS ADJACENT TO OR UNDER DWELLING <br />AREAS SHALL HAVE MATERIALS APPROVED FOR ONE -HOUR FIRE RESISTIVE <br />CONSTRUCTION. <br />2. AIR DUCTS PASSING THROUGH ONE -HOUR FIRE RESISTIVE CONSTRUCTION SHALL BE A <br />MINIMUM OF 26-GAUGE STEEL. <br />3. ALL ELECTRICAL SWITCH PLATES AND BOX COVERS IN THE GARAGE SHALL BE METAL AND <br />LIGHTS WITH BOXES BEHIND THEM SHALL NOT BE PLASTIC. <br />4. ALL PIPING PASSING THROUGH ONE -HOUR FIRE RESISTIVE CONSTRUCTION SHALL BE METAL. <br />5. AIR DUCTS AND OR PIPING SUPPORTED BY STRUCTURAL MEMBERS THAT ARE <br />REQUIRED TO BE FIRE PROTECTED SHALL BE INSTALLED AFTER THE SHEET ROCK HAS <br />BEN APPLIED. DUCTS AND OR PIPING MAY BE ENCLOSED WITHIN A SOFFIT <br />HAT HAS THE SAME DEGREE OF FIRE PROTECTION REQUIRED FOR THE STRUCTURAL <br />MEMBERS THAT IT ATTACHES TO. FRAMING MEMBERS FOR THE SOFFIT SHALL NOT <br />EXCEED 16" ON CENTER. <br />6. WATER HEATER SHALL HAVE A RELIEF VALVE DRAIN LINE TO THE OUTSIDE OF THE <br />BUILDING. PER P2803.6.1 (10) OF THE 2015 IRC, THE DISCHARGE NOT <br />TERMINATE MORE THAN 61N ABOVE THE FLOOR OR WASTE RECEPTOR. <br />7. DOOR BETWEEN GARAGE AND DWELLING UNIT TO BE SELF CLOSING 20 MINUTE RATED SOLID <br />CORE WOOD DOOR OR EQUAL <br />GENERALDEMO NOTES <br />1. LEGALLY DISPOSE OF ALL REMOVED BUILDING COMPONENTS AND RELATED DEMOLITION MATERIALS <br />2. PROTECT ALL EXISTING UTILITIES - VERIFY ALL UTILITY LOCATIONS PRIOR TO ALL <br />BUILDING DEMO AND CONSTRUCTION <br />3. CALL BEFORE YOU DIG. CALL 311 <br />i hl <br />f <br />yl <br />t. <br />2. - _ <br />DIMENSIONS, _ ALL • ; i • • ARCHITECTURAL <br />DRAWINGS. COLUMNS, FOOTINGS ARE CENTERED ON GRID TYPICAL. ALL EXISTING <br />DIMENSIONS SHALL BE FIELD VERIFIED. ALL DIMENSIONS ARE <br />TO INSIDE <br />- D`- - OF <br />ELEVATIONCONCRETE, OUTSIDE FACE OF CONCRETE OR CENTERLINE OF GRID OR CENTERLINE OF STEEL. <br />CONTINUOUS FOOTINGS ARE CENTERED UNDER WALL I STRUCTURAL PANELS. POSTS, BUNDLED <br />STUDS OR COLUMNS ARE TO BE CENTERED ON FOOTING OR WALL PIER, UNO. <br />3. TYPICAL TOP OF INTERIOR FOOTING ELEVATION 4' UNO. TYPICAL TOP OF EXTERIOR FOOTING <br />EXTERIOR FOOTINGS-.D TO AT OR BELOW FROST <br />DEPTH PERJURISDICTION REQUIREMENTS <br />4. ALL WOOD IN CONTACT WITH WEATHER EXPOSED CONCRETE F FINISHED GRADE SHALL <br />B PRESSURE TREATED. <br />5. FASTEN LEDGER WITH (4) ROWS 1/4"DIA.X4" SDS SCREWS @ 6" O.C. TYP UNO ON PLAN <br />6. ALL WALL SEGMENTS SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS. ANCHOR BOLT SHALL BE A <br />MINIMUM OF 4" AND MAXIMUM OF 12" FROM EA END. AT EXISTING FOUNDATIONS ANCHOR BOLTS <br />N, n, <br />f <br />t 6k f 5a . <br />1. FOR GENERAL STRUCTURAL NOTES, ABBREVIATIONS, DESIGN CRITERIA SEE SHEET S-1 <br />2. DIMENSIONS, VERIFY ALL DIMENSIONS AND ELEVATIONS WITH ARCHITECTURAL <br />DRAWINGS. COLUMNS, FOOTINGS ARE CENTERED ON GRID, TYPICAL. ALL EXISTING <br />INSIDE FACE OF <br />S <br />DIMENSIONS SHALL BE FIELD <br />VERIFIED. ALL DIMENSIONS <br />ARE: T® IN <br />CONCRETE, OUTSIDE FACE OF CONCRETE OR CENTERL <br />INE OF GRID OR CENTERLINE OF STEEL. <br />CONTINUOU <br />S FOOTINGS ARE CENTERED UNDER WALL / STRUCTURAL PANELS. POSTS, BUNDLED <br />STUDS OR COLUMNS ARE TO BE CENTERED ON FOOTING OR WALL PIER, UNO. <br />3. AT ALL BEARING AND SHEAR WALLS, REFERENCE STUD GRADE, SIZES AND SPACING PER PLANS <br />AND GENERAL NOTES <br />4. TOP PLATE BEARING WALL ELEVATION PER ARCHITECTURAL DRAWINGS <br />5. BALLOON FRAME ALL WALLS GREATER THAN ONE LEVEL WITHOUT FLOOR OR ROOF SUPPORT. <br />6. BLOCKING: PROVIDE SOLID BLOCKING OVERALL SHEAR AND BEARING WALLS. AT SHEAR WALLS <br />PARALLEL TO FRAMING ALIGN (1) ROOF TRUSS OR CONTINUOUS BLOCKING OVER SHEAR WALL. <br />ADDITIONAL ROOF TRUSSES MAY BE REQUIRED TO ACCOMMODATE BLOCKING. <br />7. HANGERS. ALL 2X HANGERS TO BE SIMPSON LUS SERIES, UNO. <br />3. HEADERS SHOWN BUT SPECIFIED ARE TO BE: (2)2X6 MINIMUM. HEADERS SHOWN SHALL BE <br />SUPPORTED BY (2) STUDS MINIMUM. UNO ON PLAN <br />9. GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING <br />10. FASTEN STRAP WITH (36) 16-D SINKERS ROOF JOIST TO SHEAR WALL AND PROVIDE 4X <br />BLOCKING FULL LENGTH OF SHEAR WALL WITH EDGE NAILING SHEATHING TO BLOCKING PER <br />SHEAR WALL SCHEDULE. S9.02 <br />11. EDGENAIL FULL LENGTH OF DRAG STRUT <br />12. USE OF COMPOSITION ASPHALT SHINGLES PER BUILDING PACKAGE <br />SPECIFICATION. MAINTAIN A DISTANCE OF 12" MIN. FROMANY RIDGE OR VALLEY. USE 2 <br />LAYERS OF FELT ON ROOFS WITH LESS THAN A 4/12 ROOF PITCH. USE "COR-A-VENT" <br />ROOF VENT OR EQUAL AT ENTIRE RIDGE AREA. USE ALUMINUM GUTTERS OR EQUIVALENT. <br />FINISH PLAN <br />1. ALL CEILINGS ARE PAINTED 1/2" TYPE "X" GWB, UNO <br />2. SKYLIGHTS SHALL RECEIVE WOOD TRIM AT INTERIOR SURFACES TO MATCH INTERIOR WINDOW TRIM <br />3. ALL EXPOSED STRUCTURAL CONNECTORS, BOLTS, ANCHORS, STRAPS, AND THE LIKE SHALL BE PRIMED AND <br />PAINTED BLACK WITH EXTERIOR GRADE PAINT <br />4. PROVIDE PVA PAINTED APPLICATION VAPOR BARRIER ON ALL INTERIOR GWB SURFACES ADJACENT TO <br />EXTERIOR WALL SURFACES - U.N.O. - ALL EXTERIOR WALLS TO HAVE VAPOR BARRIERS <br />5. ALL WOOD IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED <br />6. ALL EXTERIOR WOOD TO BE PRESSURE TREATED <br />7. ALL GWB TO BE TYPE "X" <br />6. ALL ELECTRICAL, MECHANICAL, PLUMBING PERMITS & DESIGN BY OTHERS <br />010 <br />• -• R , RIn <br />TABLE M1507.3.3.(2) <br />INTERMITTENT WHOLE -HOUSE MECHANICAL VENTILATION RATE FACTORS <br />RUN TIME PERCENTAGE IN <br />25% <br />33% <br />50% <br />66% <br />75% <br />100% <br />EACH 4 HOUR SEGMENT <br />FACTOR(a) <br />4 <br />3 <br />2 <br />1.5 <br />1.3 <br />1 <br />THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR <br />WHOLE -HOUSE VENTILATION SYSTEMS USING EXHAUST FANS. A SYSTEM WHICH <br />MEETS ALL THE REQUIREMENTS OF THIS SECTION SHALL BE DEEMED TO SATISFY <br />THE REQUIREMENTS FOR A WHOLE -HOUSE VENTILATION SYSTEM. <br />MI507.3.2 CONTROL AND OPERATION. <br />1. LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY <br />ACCESSIBLE BY THE OCCUPANT. <br />2. INSTRUCTIONS. OPERATING INSTRUCTIONS FOR WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE <br />PROVIDED TO THE OCCUPANT BY THE INSTALLER OF THE SYSTEM. <br />3. LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL <br />SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. <br />4. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS. CONTINUOUS WHOLE -HOUSE <br />VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY AND BE EQUIPPED WITH AN <br />OVERRIDE CONTROL. A "FAN ON" SWITCH SHALL BE PERMITTED AS AN OVERRIDE <br />CONTROL. CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM <br />WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. A CLEARLY VISIBLE LABEL <br />SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE <br />OPERATING INSTRUCTIONS)." <br />5. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS, INTERMITTENT WHOLE -HOUSE <br />VENTILATION SYSTEMS SHALL COMPLY WITH THE FOLLOWING: <br />5.1. THEY SHALL BE CAPABLE OF OPERATING INTERMITTENTLY AND CONTINUOUSLY. <br />5.2. THEY SHALL HAVE CONTROLS CAPABLE OF OPERATING THE EXHAUST FANS, FORCED -AIR SYSTEM <br />FANS, OR SUPPLY FANS WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. <br />5.3. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN SECTION <br />403.3.5.1. <br />5.4. THE SYSTEM SHALL BE DESIGNED SO THAT IT CAN OPERATE AUTOMATICALLY BASED ON THE TYPE <br />OF CONTROL TIMER INSTALLED. <br />5.5. THE INTERMITTENT MECHANICAL VENTILATION SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT <br />OF EVERY FOUR. <br />5.6. THE SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR <br />CLOCK TIMER. <br />5.7. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE THE <br />WHOLE -HOUSE FAN ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE -HOUSE FAN <br />SIZING. <br />5.6. A LABEL SHALL BE AFFIXED TO THE CONTROL THAT READS "WHOLE HOUSE VENTILATION (SEE <br />OPERATING INSTRUCTIONS)." <br />M1507.3.4.1 WHOLE -HOUSE VENTILATION FANS. <br />EXHAUST FANS PROVIDING WHOLE -HOUSE VENTILATION SHALL HAVE A FLOW RATING AT 0.25 <br />INCHES WATER GAUGE AS SPECIFIED IN TABLE MI507.3.3(1) (SEE SHEET 2). MANUFACTURERS, FAN <br />FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI 916OR AMCA 210. <br />MI 507.3.4.2 FAN NOISE. <br />WHOLE -HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SONS <br />RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE. MANUFACTURERS NOISE <br />RATINGS SHALL BE DETERMINED AS PER HVI 915 (MARCH 209). REMOTELY MOUNTED FANS SHALL <br />BE ACOUSTICALLY ISOLATED FROM THE STRUCTURAL ELEMENTS OF THE BUILDING AND FROM <br />ATTACHED DUCT WORK USING INSULATED FLEXIBLE DUCT OR OTHER APPROVED MATERIAL. <br />MI507.3.4.3 FAN CONTROLS. <br />THE WHOLE -HOUSE VENTILATION FAN SHALL MEET THE REQUIREMENTS OF SECTION M1507.3.2 AND <br />M 1507.3.2.1. <br />TABLE M1507.3.3(1) <br />CONTINUOUS WHOLE HOUSE MECHANICAL VENTILATION SYSTEM <br />AIR FLOW RATE REQUIREMENTS <br />DWELLING UNIT <br />FLOOR AREA <br />(SQUARE FEET) <br />NUMBER OF BEDROOMS <br />0-1 <br />2- 3 <br />4-5 <br />6-7 <br />AIR FLOW IN CFM <br /><1500 <br />30 <br />45 <br />60 <br />75 <br />1501-3000 <br />45 <br />60 <br />75 <br />90 <br />3001-4500 <br />60 <br />75 <br />90 <br />105 <br />4501-6000 <br />75 <br />90 <br />105 <br />120 <br />6001-7500 <br />90 <br />105 <br />120 <br />135 <br />>7500 <br />105 1-1 <br />20 <br />5 <br />150 <br />APPROVAL r, P ARE <br />THIS PROJECT <br />CATY OF EVERT <br />REVIEWED FOR PERMIT <br />�p/) <br />U) <br />7) <br />I <br />U) <br />IL <br />of <br />N <br />0 <br />1 <br />I <br />P <br />I? <br />(6 <br />co <br />f" <br />,I <br />I <br />I <br />s <br />Xresf \RAT1.0, )A_)(_ fitly rlwn <br />THIS PROJECT <br />(SFR) <br />