Laserfiche WebLink
EXTERIOR SIDE <br />I e 2X4 STUD WALL <br />SCALE: 3"=V-0" <br />INTERIOR SIDE — <br />HEATED SPACE <br />LAYER 1 /2" GYP BD. <br />R-21 CLOSED CELL SPRAY <br />INSUL. <br />PLYWD. SHEATHING PER <br />STRUCTURAL NOTES <br />(2) LAYERS 60 MINUTE <br />GRADE D BUILDING PAPER <br />HARDI SHINGLES <br />PER ELEVATIONS <br />BLOCKING AS <br />REQUIRED <br />2X4 WOOD STUDS <br />@ 16" O.C. <br />ADD PLYWOOD PER <br />SHEARWALL SCHEDULE <br />EXTERIOR SECTION <br />FLOOR FINISH PER <br />ARCHITECT <br />/4" T&G FLOOR PLYWD. <br />'REW OR NAIL AND GLUE <br />;EE FRAMING PLANS) <br />(2) 2X6 @ 16" O.C. <br />PER FRAMING PLANS <br />R-38 BATT. INSUL. @ <br />CRAWL SPACE <br />(ACOUSTIC BATT INSUL <br />@ INTERIOR BETWEEN <br />FLOORS) <br />R-38 <br />FLOOR TYPE FA <br />INTERIOR SIDE <br />(1) LAYER 1 /2" GYP BD. <br />R-21 BATT INSUL. <br />2X4 WOOD STUDS <br />@ 16" O.C. <br />EXTERIOR SIDE <br />BLOCKING AS REQUIRED <br />ADD PLYWOOD PER <br />SHEARWALL SCHEDULE <br />ONE HOUR WALL <br />PER DA WP8105 <br />(1) LAYER 5/8" TYPE "X" <br />GYP BD. EACH SIDE <br />R-21 CLOSED CELL SPRAY <br />INSUL. <br />PLYWD. SHEATHING PER <br />SHEARWALL SCHEDULE <br />(2) LAYERS 60 MINUTE <br />GRADE D BUILDING PAPER <br />HARDI SHINGLES <br />PER ELEVATIONS <br />BLOCKING AS <br />REQUIRED <br />2X4 WOOD STUDS <br />@ 16" O.C. <br />ADD PLYWOOD PER <br />SHEARWALL SCHEDULE <br />WALL TYPE <br />- 2X4 STUD WALL ® WD SIDING <br />O23 <br />SCALE:3"=V-0" EXTERIOR SECTION <br />�r <br />ONE HOUR RATED WALL <br />GA FILE NO. WP 8105 GENERIC 1 HOUR <br />FIRE <br />THICKNES: VARIES <br />APROX. WEIGHT: 7 PSF <br />FIRE TEST: SE WP 3510 <br />(UL R3501-47, —48, 9-17-65, <br />UL DESIGN U309; <br />UL R1319-129, 7-2-70, <br />UL DESIGN U314) <br />GYPSUM WALLBOARD, GYPSUM SHEATHING, WOOD STUDS <br />EXTERIOR SIDE: ONE LAYER 48" WIDE 5/8" TYPE X GYPSUM <br />SHEATHING APPLIED PARALLEL TO 2 X4WOOD STUDS 24" O.C. WITH <br />13/4" GALVANIZED ROOFING NAILS 4" O.C. AT VERTICAL JOINTS AND <br />7" O.C. AT INTERMEDIATE STUDS AND TOP AND BOTTOM PLATES. <br />JOINTS OF GYPSUM SHEATHING MAY BE LEFT UNTREATED. EXTERIOR <br />CLADDING TO BE ATTACHED THROUGH SHEATHING TO STUDS. <br />INTERIOR SIDE: <br />ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD, WATER—RESISTANT <br />GYPSUM BACKING <br />BOARD, OR GYPSUM VENEER BASE APPLIED PARALLEL OR AT RIGHT <br />ANGLES TO STUDS WITH 6D COATED NAILS, 17/8" LONG, 0.0915" <br />a <br />SHANK, 1/4" HEADS, 7" O.C. (LOAD —BEARING) <br />A <br />61 1/2 <br />If <br />i 137 1 /2 <br />Tower Industries A C <br />Meridian Solid Surface Shower Base <br />Model #: MSB615375SACCWWOL <br />Model #: MS8615375SACCWWOR <br />L <br />01X1Iil1h/bl <br />LUS HANGER <br />TYP <br />2X10 FLOOR <br />FRAMING <br />PER PLAN <br />LUS HANGER <br />TYP <br />IN <br />el W /g A <br />0C-Af6 <br />CITY OF SAMMAMISH APPROVAL AREA <br />CITY OF <br />ERETT <br />�fi' rW,Y` <br />EFUME <br />W <br />LU <br />P <br />col?) <br />ry. <br />u�I <br />Z <br />dLo <br />A9.01 <br />