Laserfiche WebLink
4'-4" <br />8'-4 1 /2„ <br />ITECTURAL PAN <br />T_� KIOSK I EQUIPMENT PLC <br />SCALE: 1 /2"=1 '-0" <br />NORTH <br />BOTTOM PANEL TO BE <br />SMOOTH FACE TO FF <br />ELEVATION <br />MANUFACTURED KIOSK <br />BY OTHERS <br />4%5 1 /4"x 1 /2" STEEL <br />ANGLE BY OTHERS -- <br />FLOOR. DECK AND STEEL <br />FRAME BY OTHERS--�,,_ <br />I <br />VAPOR BARRIER <br />PL 1 /2"x6"x6" <br />N (1) 5/8"Ox6" <br />H.A. STUD <br />I <br />6 TYP A <br />tS 1/4" <br />1 /2" EXP. JOINT W/ BACKER <br />ROD AND ELASTOMERIC <br />SEALANT <br />1/4 <br />CONCRETE PAVEMENT. SLOPE <br />AWAY FROM KIOSK, 1/8" PEP, <br />FOOT MIN. <br />z� MANUFACTURED <br />KIOSK BY OTHERS <br />FLOOR DECK & <br />STEEL FRAME BY <br />OTHERS <br />c� <br />#5 @12" O.C. EACH WAY <br />3" CLEAR <br />TYP. <br />2 6" x 2'-6" x 18 —8 _ #5 @12" O,C. EACH WAY <br />ISOLATED SPREAD FOOTING <br />KIOSK EON DTI L'ET IL AT Fu"u"TING <br />SCALE: 1 "=V —0" <br />SEE KIOSK NOTES, SHEET A1.1 <br />NORTH <br />EXTERIOR PANEL <br />6" CONCRETE LANDING <br />W/ THICKENED EDGE <br />co (5) 1 f2"Ox6" H.A. <br />STUD @ 12" O.C. <br />MAX. @ CONCRETE <br />1-0 LANDING BY KIOSK <br />MANUFACTURER <br />>_ i —VAPOR BARP,IER <br />FOOTING BEYOND ______�_— <br />I FOUNDATION DETAIL LANDING <br />SCALE: 1 "=1 ' —0" <br />SEE KIOSK NOTES, SHEET A1.1 <br />PER DETAIL, <br />3/A1.0 (TYP.) <br />SCALE: 1 /2"=1 '0" <br />SEE KIOSK NOTES, SHEET Al .1 <br />MANUFACTURED KIOSK <br />BY OTHERS <br />FLOOR DECK, STEEL <br />FRAME AND STEEL <br />ANGLE BY OTHERS <br />7 <br />UDICATES <br />IMBED PLATES <br />'ER DETAIL <br />i/A1 .0 <br />ACE OF <br />'ANEL <br />XTERIOR FACE <br />)F' PERIMETER <br />)F FLOOR <br />:HAN N EL <br />BUILT—IN MERCHANDISE <br />TRANSACTION DRAWER <br />BUILT—IN SHELF <br />4"x4"x12" GUTTER <br />INSTALL CONDUIT FOR <br />POS AND INTERCOM <br />SAFE AND DOOR <br />SWING SHOWN <br />vinqv I ITMin FI F /ATIOK <br />SCALE: 1 /2"=1'-0" <br />>" <br />8 <br />c� <br />a <br />1 /4" PLYWOOD BACKING — <br />Li <br />LL <br />2" <br />84" TYP. <br />r <br />NOTES: <br />1. CONSTRUCT WITH 3/4" MEDIUM DENSITY PARTICLEBOARD <br />2. BACK TO BE 1/4" AB GRADE PLYWOOD <br />3. FINISH EDGES WITH PINE <br />4. PRIME AND PAINT ENTIRE UNIT SHERWIN WILLIAMS SW6002 <br />"ESSENTIAL GRAY" <br />8STORAGE RAC <br />SCALE: 3,/4"=1 ' —0" <br />N <br />PLUMBING E E LNOTES: <br />1. THE CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE I-fIMSELF/HERSELF WITH ALL <br />REQUIREMENTS OF THE CONTRACT PRIOR TO SUBMITTING HIS/HER BID, THE CONTRACTOR SHALL NOTIFY <br />TI"""lE ARCHITECT/ENGINEER OF ANY CONFLICTS PRIOR TO BID OR START OF INSTALLATION. <br />2. THE CONTRACTOR SHALL ARRANGE FOR ALL INSPECTIONS WHEN THEY BECOME DUE AND SHALL NOT <br />COVER ANY WORK UNTIL APPROVED BY THE INSPECTION AUTHORITY. <br />3. THE INFORMATION PRESENTED ON THESE DRAWINGS IS DIAGRAMMATIC IN NATURE. IT DOES NOT <br />NECESSARILY REPRESENT ALL FITTINGS, HANGERS, ETC, REQUIRED FOR A COMPLETE WORKING SYSTEM. <br />PROVIDE ALL MATERIALS AND LABOR FOR COMPLETELY FINISHED AND OPERATIONAL SYSTEMS, <br />4. CONTRACTOR SHALL. NOTIFY THE ENGINEER OF ANY ALTERATIONS REQUIRED BY THE OWNER OR FIELD <br />CONDITIONS. <br />5. ALL EQUIPMENT SHALL BE NEW, SHALL COMPLY WITH SPECIFICATIONS ON DRAWINGS, AND SHALL <br />COMPLY WITH ENERGY CONSERVATION CODE REQUIREMENTS AS ADOPTED BY THE STATE, AS WELL AS <br />LOCAL JURISDICTIONAL BUILDING DEPARTMENT. <br />6. THE CONTRACTOR SHALL PROVIDE PLUMBING EQUIPMENT, FITTINGS, AND TRIM WHERE SPECIFIED OR AS <br />REQUIRED FOR COMPLETE INSTALLATION. THE CONTRACTOR SHALL ROUGH —IN AND CONNECT ALL <br />EQUIPMENT INCLUDING EQUIPMENT FURNISHED BY OTHERS. <br />7. VENTS THRU ROOF SHALL BE INSTALLED A MIN. OF 10 FT FROM OR TERMINATED A MIN. OF 3 FT <br />ABOVE FRESH AIR. INTAKES. <br />8. SHUT—OFF VALVES SHALL BE INSTALLED AT ALL EQUIPMENT WATER SUPPLY CONNECTIONS. <br />9. THE CONTRACTOR SHALL INSULATE EXPOSED HOT WATER LINES AND LAVATORY DRAIN PER BUILDING <br />DEPARTMENT AND A.D.A. REQUIREMENTS, <br />10, REFER TO KIOSK MANUFACTURER DRAWINGS FOR STUB —UP LOCATIONS. <br />EXTERIOR PANEL <br />1 /2" EXP. JOINT W/ <br />BACKER ROD AND <br />ELASTOMERIC SEALANT <br />CONCRETE PAVEMENT <br />SLOPE AWAY FROM KIOSK, <br />1 /8" PER FOOT MIN. <br />,VAPOR. BARRIER <br />v --FOOTING BEYOND <br />KIOSK FOUNDATION DETAIL BETWEEN FOOTINGS <br />SCALE: 1"=1'-0" <br />SEE KIOSK NOTES, SHEET A1.1 <br />EQUIPMENT LEGEND <br />ALL EQUIPMENT FURNISHED BY OWNER UNLESS OTHERWISE SPECIFIED <br />0 4' STORAGE RACK — FURNISHED AND INSTALLED BY G.C. <br />0 CANDY RACK WITH 10" DEEP COUNTERTOP, 3 SHELVES AND WIRE <br />LOTTERY RACK -- FURNISHED AND INSTALLED BY G.C. <br />(D CHAIR <br />4 LOTTO MACHINE <br />SAFE <br />P.O.S. REGISTER <br />8� BACK OFFICE P.O.S. INSTALLED BY OWNER <br />88 IANK MONITOR <br />(�) CIGARETTE CARTON MERCHANDISER <br />110 CIGARETTE PACK MERCHANDISER <br />'1 46 C.F. ICE MERCHANDISER <br />12 HABCO/TRUE COOLER AND SHROUD PROVIDED BY KROGER, INSTALLED <br />BY G.C. <br />13 ENERGY/HYDRATION COOLER AND SHROUD PROVIDED BY KROGER, <br />INSTALLED BY G.C. <br />14 2—A: 20—B:C FIRE EXTINGUISHER BY G.C. QUANTITIES AND LOCATIONS <br />INSTALLED PER LOCAL CODE. <br />15 ANTI —FATIGUE MAT <br />16 DEAL TRAY/MERCHANDISE DRAWER <br />17 PANEL BOARD <br />18 DESK EQUIPMENT RACK — 40 1/2"W x 40 78"T x 22"D, WALL <br />MOUNTED <br />8 NOT USED <br />20 6" PIPE BOLLARD — FURNISHED AND INSTALLED BY G.C. (TYP. 4) <br />�8 BULLETIN BOARD — G.C. TO MOUNT ABOVE PEEPHOLE. <br />22 INTERCOM MASTER STATION INSTALLED BY G.C. <br />�3) CIGARETTE MERCHANDISING SIGN PANELS. <br />24 3 DRY MERCHANDISERS INSTALLED BY G.C. (ONLY USED ON STACKED <br />DISPENSER LAYOUTS), (REFER TO A1.1) <br />8 2—A: 20—B:C FIRE EXTINGUISHER IN STEEL CABINET TYP. CONFIRM <br />QUANTITY AND LOCATIONS WITH LOCAL AUTHORITY HAVING JURISDICTION. <br />(STP,IKEFIRSTUSA.COM #999CL WITH "ACRYLIC 999" REPLACABLE COVER). <br />CABINET TO BE SUPPLIED BY OWNER AND INSTALLED BY G.C. MOUNT <br />BOTTOM 32" ABOVE PAVING. WHEN INSTALLED WITHIN CLADDING, SHIM <br />BACK OF CABINET TO ALLOW FACE OF CABINET TO BE HELD OUT 2 1/2" <br />FROM FACE OF SURROUNDING COLUMN CLADDING FOR CHAIN BREAK <br />MOUNT. CIVIL ENGINEER MUST VERIFY ACCESSIBILITY. REFER TO A1.1 FOR <br />INTENDED LOCATIONS, <br />26 INTRUSION ALARM KEYPAD <br />27 EMERGENCY 911 CALL BOX MOUNT CENTERLINE AT +48" A.F.G. <br />28 COPPER WATER SERVICE LINE ENTRANCE. PROVIDE 1" THICK CLOSED CELL <br />PIPE INSULATION FROM 1" BELOW FLOOR TO 12" BELOW FROST LEVEL <br />WITH PVC HARD SHELL JACKET. SEE CIVIL AND KIOSK MANUFACTURER'S <br />DRAWINGS. <br />29 BACKFLOW DEVICE, SEE KIOSK MANUFACTURER'S DRAWINGS. <br />30 NOT USED <br />31 FLOOR DRAIN, SEE KIOSK MANUFACTURER'S DRAWINGS. <br />32 CONNECTION TO KIOSK WATER PIPING SEE KIOSK MANUFACTURER'S <br />DRAWINGS. <br />33 GRAB BARS (TYP.) --- INSTALLED BY KIOSK MANUFACTURER. <br />34 NOT USED <br />,35 INSTANTANEOUS ELECTRIC WATER HEATER — INSTALLED BY KIOSK <br />MANUFACTURER. <br />36 CONNECT TO SANITARY SEWER, SEE CIVIL AND KIOSK MANUFACTURER'S <br />DRAWINGS. <br />37 WATER CLOSET SUPPLIED AND INSTALLED BY KIOSK MANUFACTURER, <br />38 NOT USED <br />,39 LAVATORY INSTALLED BY KIOSK MANUFACTURER, SEE KIOSK MANUFACTURER'S <br />DRAWINGS. <br />40 NOT USED <br />@1 FROSTPROOF HOSE BIBB BY KIOSK MANUFACTURER, SEE KIOSK <br />MANUFACTURER'S DRAWINGS. <br />42 MOP SINK BY KIOSK MANUFACTURER, SEE KIOSK MANUFACTURER'S <br />DRAWINGS. <br />43 G.C. TO INSTALL OVERHEAD DOOR, STOP — GYLNN—JOHNSON, 90 SERIES,. <br />US32D FINISH, WITH HOLD OPEN AND SEX NUT BOLT — TO RESTRICT DOOR <br />OPENING TO APPROXIMATELY 90 DEGREES. MUST MAINTAIN A MINIMUM OF <br />32" CLEAR FROM ALL HARDWARE FOR INGRESS. <br />44 SPILL CABINET PROVIDED BY KROGER, INSTALLED BY G.C. — FIELD VERIFY <br />EXACT LOCATION WITH KROGER P.M. <br />45a SHELF CABINET WITH SHELVES PROVIDED BY KROGER, INSTALLED BY G.C. — <br />SEE SHEET A1.1 <br />45b SHELF CABINET WITH NO SHELVES PROVIDED BY KROGER, INSTALLED BY <br />G.C. — SEE SHEET .A1.1 <br />46 WASTE/WINDSHIELD SERVICE CENTER PROVIDED BY KROGER, INSTALLED BY <br />C_C — SEE SHEET A1.1 <br />8 FIREWOOD CAGE PROVIDED BY KROGER, INSTALLED BY G.C. — SEE SHEET <br />A1.1 <br />43 EMERGENCY FUEL SHUTOFF <br />49 SECURITY PANEL <br />G.C. TO VERIFY WITH <br />PROJECT MANAGER <br />AND FUEL MANAGER PRIOR TO <br />EINAL. <br />PLACEMENT GE ALL MERCHANDISER <br />EQUIPMENT AND SPILL CABINETS <br />7 <br />�I <br />E <br />w � <br />In <br />V) <br />�0— <br />0z <br />a CO <br />c w <br />.2 z ai <br />V C <br />�aa <br />Q my <br />U 00 C <br />CJ h� 00 CD <br />QO I <br />N N <br />a��rr7 I <br />0 Nn- <br />O <br />U; �7 <br />CDax <br />CO 6 L p <br />i� 97 <br />P .EGISTEREI <br />SRCHI ECT <br />DAB, IEL B GOAL ',' <br />STkE OF SH#NGTON <br />E'Fe 1/ <br />N <br />C� <br />N N <br />w 0 <br />d- <br />< I o <br />© � I <br />I � <br />co <br />0 0 <br />�m 0L <br />u� <br />z <br />G <br />LL_I <br />z <br />_ <br />z <br />0 <br />m <br />0 <br />L� <br />�. <br />J <br />r <br />m <br />o <br />F- <br />z <br />f— <br />Um <br />0 <br />cr- <br />(n <br />0 <br />LLJ <br />Project #: 20996 Store ,#00852 <br />Designed By, RSG <br />Drawn By: MMH <br />Checked By: RSG <br />Date: 6-4-2021 <br />Scale: <br />Disk File: <br />Model: <br />Address: <br />NEC EVERGREEN WAY @ 50TH <br />STREET SE <br />EVERETT, WA 98203 <br />FLOOR PLAN <br />FOUNDATIONS <br />