(N) WALL MOUNTED <br />ALUMINUM GUARDRAIL; <br />REF 1 A/A3.3 FOR ELEV <br />TYP (N) WALL & STRINGER <br />OPP MOUNTED ALUMINUM <br />HANDRAIL; REF 6A/A5.5 - <br />FOR STRINGER <br />[ATTACHMENT <br />TRIM-2, TYP; <br />PNT-6 <br />HANDRAIL - <br />MOUNT <br />BRACKET; <br />REF 6D/A5.5 <br />17A Y 1B <br />A5.3 A5.4 l <br />OPP <br />[iL� <br />I <br />I <br />1C <br />I <br />I <br />I <br />A LANDING @ TOP OF STAIR - FRONT <br />i <br />(N) STRINGER & TOP <br />MOUNTED ALUMINUM <br />GUARDRAIL W/ HANDRAIL <br />9 <br />5.5 <br />@ STRINGER <br />- @ WALKWAY <br />T/O <br />.. ..------LANDINGMALWAY-._0_ <br />(E) STRINGERS & TREADS; RE/RE <br />W/ (N) RISER CLOSURE PLATES, <br />TYP; REF 19/A5.5 <br />PNT-7 @ STRINGER, TYP <br />NOTES: <br />1. GUARDRAIL ELEVS SHOWN HEREIN ARE GENERAL & MAY NOT REPRESENT ALL <br />GUARDRAIL CONFIGURATIONS. REF NOTES, PLANS & ARCH FOR VARIATIONS. <br />2. REFER TO SHEETS A3.1 & A3.2 FOR PLANS INDICATING SLOPING & GUARDRAIL <br />LAYOUTS FOR TYP STAIRS, LANDINGS & WALKWAYS. <br />3. REF SHEETS A5.5 & S2.0 FOR TYP HANDRAIL/GUARDRAIL INTERFACE DETAILS. <br />4. LANDING & WALKWAY DIMENSIONS VARY; CONTRACTOR TO VIF. <br />5. WALL MOUNTED GUARDRAILS SHALL BE INSTALLED LEVEL @ TOP & BOTTOM <br />RAILS. ESTABLISH 42" HIGH MIN WHERE GUARDRAILS MEET BLDG. <br />6. WHERE THEY OCCUR, COORD ALL FASTENER LAYOUTS W/ ARCH; LAYOUTS MAY <br />VARY. <br />7. REFER TO STRUCT, SECTION 01 10 00 - DESCRIPTION OF THE WORK & SHEET A0.3 <br />FOR REFRAMING & SELECT STRUCTURAL COMPONENT REPAIR, WHERE OCCURS. <br />COORD W/ ARCH. <br />8. WHERE (E) SIGNS ARE MOUNTED IN AREAS OF SIDING REPLACEMENT, RE/RE <br />SIGNS; COORD W/ ARCH FOR DIRECTION. REF 16/A5.1. <br />9. REF 1/A0.2 FOR PAINT INFO & LOCATIONS. COORD W/ ARCH. <br />10. SID-1 LAYOUT: STAIR TOWER ELEVATIONS SHOW CONCEPTUAL LAYOUT FOR SID-1 <br />& REVEALS. ALIGNMENTS OF SELECT REVEALS ARE NOTED ON STAIR TOWER <br />ELEVATIONS. COORD FINAL LAYOUT W/ ARCH PRIOR TO INSTALL. <br />11. SLOPING: SLOPE ELEVATED WALKWAYS & LANDINGS MIN 1/4" PER FT @ ALL <br />LOCATIONS. INSTALL PLY-1 O/ TAPERED SLEEPERS, TYP. COORD LOCATIONS & <br />ANGLES OF VALLEYS W/ ARCH. LAST RISER @ TOP STEP SHALL MATCH (E), TYP. <br />12. SOFFIT VENTILATION: @ ALL ELEVATED WALKWAYS EXCEPT TOP FLOORS, INSTALL <br />VENT-1, TWO PER SOFFIT. LOCATE VENTS CONSISTENT DIMENSIONS FROM FRONT <br />EDGES & BACK WALLS, TYP. REFER TO 8D/A5.3. COORD W/ ARCH FOR LOCATIONS. <br />13. GUARDRAIL ELEVATIONS: REF SHEETS A3.3 & A3.4 FOR TYPICAL GUARDRAIL <br />CONFIGURATIONS. <br />14. LANDING & WALKWAY FRAMING, TAPERED SLEEPERS & SHEATHING NOT SHOWN <br />FOR CLARITY. <br />TYPICAL ENLARGED STAIR LANDING SECTIONS <br />lit = 1'-0" <br />NOTE: INTERMEDIATE FLOOR <br />LANDING SHOWN. SIM @ TOP (N) WALL MOUNTED ALUMINUM <br />18C <br />FLOOR W/ RECTANGULAR COLUMN. GUARDRAILS; REF SHEET A3.3 A5.2 <br />FOR ENLARGED ELEVS OPP (E) VINYL SIDING; RE/RE <br />SID-1, TYP AS REQ'D TO ACCOM <br />TRIM-�\ WORK, TYP <br />PNT-62� TYP, \ <br />A5.2 I <br />SIM <br />X\\--REV-5, <br />6DA5.2 TYP <br />REV-4 <br />B LANDING @ TOP OF STAIR - SIDE <br />TRIM-2, TYP; <br />\PNT-6 <br />(E) VINYL SIDING; RE/RE <br />AS REQ'D TO ACCOM <br />WORK, TYP <br />(N) STRINGER & TOP <br />MOUNTED ALUMINUM <br />GUARDRAIL & <br />HANDRAIL <br />BASE PLATE O/ EPDM- <br />SHIM @ STRINGER; REF <br />6A/A5.5 & 2/S2.0 <br />@ WALCQ- " %@ WALKWAY <br />EDGE <br />19A <br />A5.4 A5.5 <br />(E) STRINGER & SIM <br />RE/RE W/ (N) 5.5 <br />TREADS; \-PNT-7 @ <br />RISER CLOSURE @ STRINGER <br />PLATES, TYP STRINGER <br />C LANDING @ TOP OF STAIR - SIDE <br />NOTE: INTERMEDIATE FLOOR <br />LANDING SHOWN. SIM @ TOP <br />FLOOR W/ RECTANGULAR COLUMN. <br />•=CAM <br />TRIM-2; \L-(E) STRINGERS & TREADS; RE/RE <br />PNT-6 W/ (N) RISER CLOSURE PLATES, <br />TYP <br />1A (N) WALL MOUNTED ALUMINUM <br />GUARDRAILS; REF SHEET A3.3 <br />FOR ENLARGED ELEVS <br />REV-5, TYP <br />TRIM-2; <br />PNT-6 <br />18B 18A <br />A5.2 5.3 <br />TYP @TOP FLOOR <br />-TRIM-2, TYP; <br />PNT-6 <br />SID-1, TYP <br />8 <br />k5.1 <br />TYP @ INT CORNER <br />8B <br />�5.3 <br />1B <br />I - _ -T/O LANDING/WALKWAY <br />AMENTOGROUP <br />710 2nd Avenue, Suite 400 <br />Seattle, WA 98104 <br />amentogroup.com <br />9016 REGISTERED <br />ARCHITECT <br />r <br />�L. <br />LISA CLARK MOE <br />STATE OF WASHINGTON <br />The documents created by the <br />Architect and its Consultants <br />for this project are instruments <br />of the Architect's service. The <br />Architect retains all common <br />law, statutory and other <br />reserved rights, including the <br />copyright. The Architect's <br />documents shall not be used <br />by anyone on any other <br />project, except with the <br />Architect's written permission. <br />GREENS OF <br />MERRILL CREEK <br />APARTMENTS <br />BLDG 2 <br />1707 MERRILL CREEK PKWY <br />EVERETT, WA 98203 <br />STAIR <br />REMEDIATION <br />SCOPE OF <br />REPAIR <br />WATERPROOFING & <br />FLASHING DETAILS <br />PERMIT SET <br />PROJECT M <br />070042 <br />DRAWN BY: <br />AJL, DGS, HLS <br />CHECKED BY: <br />MFV, MNM <br />REVISIONS: <br />10-16-2020 PERMIT SET <br />BLDG DEPT <br />I 6 B IM DATE: <br />A5.3 10-16-2020 <br />S <br />SHEET TITLE: TYPICAL <br />\ ENLARGED <br />REV-4 <br />LANDING <br />SECTIONS <br />BUILDING TYPE: <br />N/A <br />SHEET #: <br />A3E4 <br />