BUILDING CODE & REFERENCE STANDARDS: The "International Building Code" (I8C),2O15Edition, omadopted and modified bythe City nfEverett, <br />Washington, governs the design and construction nfthis project. Reference toaspecific section inthe Code does not relieve the contractor from <br />compliance with the entire materials reference standards noted below. The latest edition ofthe materials reference standards shall baused. <br />SCOPE OFSTRUCTURAL WORK: The structural scope of work involves the repair to structural damages in existing entry and egress stair structures at <br />aseries m[apartment buildings. <br />DEFINITIONS: The following definitions apply tothese general notes: <br />* "Structural Engineer of Record" (EOR)-The Structural Engineer who islegally responsible for stamping & signing the structural documents <br />for the project. The EOR is responsible for the design of the aspects of the Primary Structural System impacted by this project. <br />° "Specialty Structural Engineer" (SSE) - A licensed professional Engineer, not the FOR, who performs specialty structural engineering <br />services necessary to complete the structure, who has experience and training in the specific specialty. The General Contractor, <br />subcontractor, or supplier who is responsible for the design, fabrication and installation of specialty -engineered elements shall retain the <br />SSE. Submittals shall bestamped and signed bythe SSE. Documents stamped and signed bythe SSE shall becompleted byorunder the <br />direct supervision of the SSE with a PE or SE license issued by the State of Washington. <br />m "Deferred Submittals ' Deferred Submittal ioengineering work tobedmoigned'by-othersnrbiddopdeaigned. <br />NOTE PRIORITIES: Notes on the individual drawings shall govern over these general notes. <br />Refer to these notes, structural drawings, and architectural drawings which serve as specifications for this project. <br />STRUCTURAL DETAILS: The structural drawings are intended hoshow the general character and extent ofthe project and are not intended toshow all <br />details nfthe work. <br />ARCHITECTURAL DRAWINGS: Refer to the Architectural drawings for information including, but not limited to: dimensions, elevations, slopes, door and <br />window openings, stairs, curbs, drains, depressions, railings, waterproofing, finishes and other nonstructural items. <br />STRUCTURAL RESPONSIBILITIES: The EOR is responsible for the strength and stability of the Primary Structure in its completed stake. <br />CONTRACTOR RESPONSIBILITIES: The contractor is responsible for the means and methods of construction and all job -related safety standards such <br />as OSHA and WISHA. The contractor is responsible for the strength and stability of the structure during construction and shall provide temporary <br />shoring, bracing and other elements required to maintain stability until the structure is completed. It is the contractor's responsibility to be familiar with the <br />work required inthe construction documents and the requirements for executing iiproperly. <br />DISCREPANCIES: In case of discrepancies between these general notes, the contract drawings and specifications, and/or reference standards, the <br />EOR shall determine which shall govern. Discrepancies shall babrought tothe attention ufthe EORbefore proceeding with the work. Accordingly, any <br />conflict in or between the Contract Documents shall not be a basis for adjustment in the Contract Price. <br />VERIFICATION:SITE The contractor shall verify all dimensions and conditions at the site prior to fabrication and/or construction.Conflicts between the <br />drawings and actual site conditions shall be brought to the attention of the FOR before proceeding with the work. All underground utilities shall be <br />determined bythe Contractor prior 0oexcavation ordrilling. <br />ADJACENT UTILITIES: The contractor shall determine the locations of all adjacent underground utilities prior to excavation. Any utility information <br />shown on the drawings and details is approximate and not necessarily complete. <br />DESIGN CRITERIA <br />CONSTRUCTION LOADS: Loads on the structure during construction shall not exceed the design loads mthe capacity of the partially completed <br />ounstmuWm. <br />Floor Total Load Deflection Limit: L/240 <br />Floor Live load Deflection Limit: U560 <br />LIVE LOADS: <br />Stairs &Landings 100PSFOR300#(4"x4"S&R) <br />Balcony Railing & Guardrails (Cnmmorcia|) 5UPLFOR2O0#(TOP RAIL) <br />Balcony Railings & Guardrails (Compnnents) 30PSF(12^)(12''SORj(1) <br />(1) Component reactions need not becombined with top rail loadings. <br />SUBMITTALS: Shop Drawings shall be submitted to the Architect/EOR prior to any fab6cationmconstruction for all structural items. The contractor shall <br />review and place a shop drawings stamp on the submittal before forwarding to the EOR. Submittals shall be made in time to provide a minimum of one <br />week for review by the EOR. Additional submittals required for this project are specified in the specific sections below. Reference the individual material <br />section for specific information h/boincluded inthe submittal. <br />ALTERNATES: Product or manufacturer components specified in these drawings are used as the basis of design for this project, Alternates for specified <br />items may be submitted to the EOR for review. However, contractor shall submit a current ICC-ESR/IAPMO-ER report identifying that an alternative <br />component has the same orgreater load capacity than the specified item. <br />SHOP DRAWING REVIEW: Review by the ArchitecVEOR is for general compliance with the design concept and the contract documents. Dimensions <br />and quantities are not reviewed by the EOR, and therefore, must be verified by the General Contractor. Markings or comments shall not be construed as <br />relieving the contractor from compliance with the project plans and specifications, departures1honefrn therefrom. The remains responsible for <br />details and accuracy; for confirming and correlating all quantities and dimensions; for selecting fabrication processes; for techniques of assembly; and <br />for performing work in a secure manner. When shop drawings (component design drawings) differ from or add to the requirements of the Structural <br />drawings they shall bedesigned and stamped bythe responsible SSE. Allow one week for EORreview time. <br />DEFERRED SUBMITTALS: Per IBC Section 107.3.4.1, drawings, calculations, and product data for the design and fabrication of items that are <br />clesigned-byothers shall bear the sea] and signature of the Washington State Registered Professional Engineer (SSE) who is responsible for the design <br />and shall be submitted to the Architect/EOR and the building department for review prior to fabrication. Allow one week for EOR review time. <br />The SSE shall submit stamped and signed calculations and shop drawings to the EOR for review. Review of the SSE's shop drawings is for general <br />compliance with design criteria and compatibility with the design of the primary structure and does not relieve the SSE of responsibility for that design. All <br />necessary bracing, ties, anchorage, and proprietary products shaUbefumimhodandinsto||edpormanutsdum/minstmdionaorthoSSE'sdmoiQn <br />drawings and calculations. Submitted drawings shall indicate all reaction forces imparted to the primary structure. Submitted calculations are furnursory <br />review only and will generally not h*returned, Deferred submittals include but are not limited hothe following: <br />Handrails &Guardrails <br />NON-STRUCTURAL COMPONENTS: Design, detailing and anchorage of all nonstructural components shall be in accordance with ASCE 7-10, Chapter <br />13 and the project specifications. Nonstructural components designed by others shall not induce torsional loading into supporting steel structural <br />members without additional bracing of those members to eliminate torsional forces. Torsional bracing shall bedesigned bythe nonstructural component <br />designer and approved by the EOR. Anchorage to the primary structure is per the bidder -design contractor or supplier. <br />TESTS &|NSPECT|tJNS <br />INSPECTIONS: All construction iasubject to inspection by the Building Official in accordance with IBC See 110. The contractor shall coordinate all <br />required inspections with the Building Official. Submit copies ufall inspection reports bothe AmhitedUEORfor review. The Building Offioia|may accept <br />inspection of and reports by approved inspection agencies in lieu of Building Official's inspections. The contractor shall obtain approval of Building <br />Official bouse the third -party inspection agency and contractor shall alert the Amhiteot/EOReosuch. <br />PREFABRICATED CONSTRUCTION: All prefabricated construction shall conform tothe inspection requirements of the same material mconstruction <br />type used for this project. <br />STRUCTURAL OBSERVATIONS: VYhonmquimdbythepmvuionoofSoction17O4.O.1m1704.G1theOwua/urthe0wnohyuuthuhzadagontuhd| <br />employ the FOR to perform structural observations. Structural observations do not include or waive the responsibility for the inspections in Section 110 <br />urthe special inspections inSection 1785orother sections inthe code. <br />The following structural observations are required to be completed by the EOR during construction. The EORioVobonotified when elements listed <br />below are substantially complete and ready for observation. Contact the EORaminimum uf(2)business days prior &ocovering the work. <br />0 Substantial completion dFloor Framing Repairs <br />STRUCTURALSTEEL <br />DESIGN STANDARDS: Structural steel for this project is designed in accordance with the latest edition u/the A0CSteel Construction Manual <br />REFERENCE DARDS: Conform to: <br />(1) A|SC"Code nfStandard Practice for Steel Buildings &BhdQea.^ <br />(2) RCSC"Specification for Structural Joints using A8TMA325orA48OBo|ts.^ <br />(3) AWGD11"Structural Welding Code 'Steei" <br />(1) Submit shop drawings in accordance with AISC Specification See M1 "Shop and Erection Drawings." <br />Bars &Plates ASTMA38.Fy=38koi <br />CAST -IN -PLACE CONCRETE <br />REFERENCE STANDARDS: Conforms dothe latest editions o[the following: <br />(i) AC|3i8"Building Code Requirements for Structural Concrete and Cummentary". <br />(2) IBC Chapter 19. <br />FIELD REFERENCE: The contractor shall keep ocopy of AC|Field Reference manual.SP-15, "Standard Specifications for Structural Concrete (ACI <br />3O1)with Selected AC and ASTMRufemncen." <br />CONCRETE MIXTURES: Conform 0oAC|310Chapter iQ^Cunumte:Design and Durability Requimments.^ <br />MATERIALS: Conform b»AC|318Chapters 1O&2O. <br />SUBMITTALS: Provide all submittals required byAC|3U1 See 4.1.2.Submit mix designs for each mix inthe table below. <br />TABLE OF MIX DESIGN REQUIREMENTS <br />Member Strength Test Age Maximum Exposure Max Minimum <br />C| M ation VV8C Ratio Air Content <br />"Porches, carports, steps exposed to 3000 28 ill F3, C2 0.40 4.5% <br />Weather & garage slabs nngrade <br />Fnundationn-remidondo|foohnQo 3500 28 i^ F1.CO 030 4.5% <br />& stem walls below grade <br />NOTES:MIX DESIGN <br />(1) VNCRatio: VVeter-uamantitiouamaterial ratios shall bebased unthe total weight ufoonmnbtiuummaterials. Ratios not shown in the table above <br />are controlled bystrength requirements. <br />(2) ComenddouoContent The use of fly ash, other pozzolans, silica fume, or slag shall conform to ACI 301 See 4.2.2 9b. Maximum amount nffly <br />ash shall be 20% of total cementitious content unless reviewed and approved otherwise by EOR. <br />(3) Air Content: Conform to ACI 301 See 4.2.2.4. Horizontal exterior surfaces in contact with the soil require entrained air. Use Exposure Category <br />FO, SO, WO, and CO unless noted otherwise. Tolerance is +/- 1.5%. Air content shall be measured at point of placement. <br />(4) Exposure C|uuoifimdion:The mix design provided shall meet the requirements nfAC|31DChapter 1Q.based unthe exposure classification <br />indicated inthe table above. <br />(5) Slump: Unless otherwise specified or permitted, concrete shall have at the point of delivery, a slump of 4" +/- 11". For additional criteria, <br />reference AC|301 Soo422.2. <br />FORMWORK Conform hoAC|3O1 See 2 "Formwork and Form Accessories." Removal of Forms shall conform to See 2.3.2 except strength indicated in <br />See 2.32.5shall beOJ5yo. <br />MEASURING, MIXING, AND DELIVERY: Conform boAC|301See 4�. <br />PLACING, OS UCT|N8ANDCUR|NG:Conform0oAC|3O1Sec5. <br />CONSTRUCTION JOINTS: Conform boAC|3UiSee 222.5.5]2.3a.522].and 6.32G.Construction joints shall bolocated and detailed aoonthe <br />construction drawings. Use of an acceptable adhesive, surface retarder, Portland cement grout, or roughening the surface is not required unless <br />specifically noted on the drawings. Where shear bond is required, roughen surfaces to 1/4" amplitude. <br />EMBEDDED ITEMS: Position and secure in place expansion joint material, anchors and other structural and non-structural embedded items befor <br />placing �� Contractor e|o�huu| plumbing, anda�hi�d�m|dmwingoandcoo�ino0ea||o�horombodd�di�mm <br />. o gcono � . . . . <br />GROUT: Consult Simpson Strong -Tie Catalog for description of grouts listed below. <br />Anchor Bolts and Rebar. Use Simpson SET-XP (greater than 40F) epoxy adhesive grout or Simpson Acrylic -Tie Adhesive AT-XP (less than 40F). <br />BONDING AGNT:UoaMoNerBui|domConceoiwaLiquid(LPL).App|yinammrdanoewithmonufoctum/ainotruudone. <br />JOINT COMPOUND: Provide acid resistant silicone caulk where noted on the drawings. Submit product data for review. <br />LEAN CONCRETE BACKFILL: Conform to recommendations of ACI 229R "Controlled Low Strength Materials (CLSM)" for mixing and placing lean <br />concrete backfill shown on the drawings. Use 100 PSI mix. Use standard slump test to verify flowability. Test in accordance with ASTM D4832-88 <br />"Preparation and Testing nfSoil-Cement Slurry Test Cylinders." <br />TESTING AND ACCEPTANCE: <br />Testing: Obtain samples and conduct tests in accordance with ACI 301 See 1.6.4.2. Additional samples may be required to obtain concrete strengths at <br />alternate intervals than shown below. <br />� Cure 4 cylinders for 28-day test age. Test 1 cylinder at 7 days, test 2 cylinders at 28 days, and hold 1 cylinder in reserve for use as the EOR <br />directs. After 56 days, unless notified by the EOR to the contrary, the reserve cylinder may be discarded without being tested for specimens <br />meeting 28-doystrength requirements. <br />Acceptance: Strength imsatisfactory when: <br />m The averages of all sets of 3 consecutive tests equal or exceed the specified strength. No individual testfalls below the specified strength by <br />more than 500 psi. A "tesf' for acceptance is the average strength of the two cylinders tested at the specified testage. <br />CONCRETE REINFORCEMENT <br />REFERENCE STANDARDS: Conform to: <br />(i) ACI 301 "Standard Specifications for Structural Concrete."Sec 3" Reinforcement, and Reinforcement Supports." <br />(2) IBC Chapter 1O.Concrete. <br />(3) AC|318and AC 310l <br />WQ ACI SP-66 "ACI Detailing Manual" including ACI 315 "Details and Detailing of Concrete Reinforcement." <br />SUBMITTALS: Conform to ACI 301 See 3.1.1 "Submittals, data, and drawings." Submit placing drawings showing fabrication dimensions and locations <br />for placement o[reinforcement and reinforcement supports. <br />Reinforcing Bars ASTMA815.Grade GO.deformed bars. <br />Weldable Reinforcing Bars ASTMA708.Grade 8O.deformed bars. <br />Smooth Welded Wire Fabric ASTMAi85 <br />Bar Supports CRG|MSP-2.Chapter 3"Bar SuppoMa." <br />Tie Wire 18.5gage urheavier, black annealed. <br />FABRICATION: Conform 8oAC|3O1.See 312^Fabrimahnn.^and AC|SP'8G"AC|Detailing Munuo|." <br />WELDING: Bars shall not bawelded unless authorized. When authorized, conform toAC|301.See 3212. "WeNing^and provide ASTNA70G.Grade <br />80minbnmment. <br />PLACING: Conform toAC|381.See 3.32^P|ooemani''Placing tolerances shall conform hoSee 3.311'7u|emnmao.^ <br />COVER:CONCRETE Conform 0xthe following cover requirements from AC|3O1.Table 3.32.3. <br />Concrete cast against earth J'' <br />Concrete exposed toearth orweather (#5&smaller) 1'1/2" <br />SPLICES & DEVELOPMENT LENGTH: Conform toAO301.See �3.2IRefer to Lap Splice & Development Schedule fox3000 psi concrete below <br />Lap all continuous reinforcement and corner bars per Schedule. The splices and development lengths indicated unindividual sheets control over the <br />schedule. Use Class 8splices unless otherwise noted. Mechanical connections may be used when approved by the EOR. <br />LAP & DEVELOPMENT SCHEDULE (Concrete strength fo=3OOO) <br />Bar Designation Lan Lencith, Ls Development Length, Ld <br />#4 32" 24" <br />WWF 8" on all sides and edges <br />WELDING: Conform kuAWSD11Welders shall be certified in accordance with AWS and WABO requirements. Use E70 electrodes of type required for <br />materials to be welded. <br />Conform to AISC Specification See M2 "Fabrication.^AISCCode See 6 "Fabrication and Delivery" and AISCCode See <br />"Quality Control." The fabricator and erector shall maintain mquality control program Nthe extent deemed necessary so that all of the work is performed <br />inaccordance with this Code, the AISC Specification, contract documents, and project specifications. <br />SHOP PAINTING: Conform toAISC 360,AISC Specification Sec M3, and AISCCode See �Do not paint steel to be embedded in concrete, <br />fireproofed, mconcealed bythe interior building finish. All other interior steel shall bopainted with one coat ofgrey shop primer. All exposed exterior <br />steel shall be painted with an exterior multi -coat system as per the Architect or project specifications or galvanized per section below.Field touch-up <br />painting shall bawith primer for exposed interior surfaces and as per the Architect or project specifications for exposed exterior surfaces. <br />GALVANIZING: Where required, all exposed steel outside the building envelope shall be hot -dipped galvanized.Apply field touch-ups per project <br />specifications. <br />ALUMINUM FRAMING <br />REFERENCE STANDARDS: Conform to: <br />(1) AAASM26and part 1Aand 1Buf"The Aluminum Design Manual.^ <br />(2) "Aluminum Standards and Duta." <br />MATERIALS: <br />Extruded Shapes Aluminum Alloy G0U5-T5 <br />Plates &Angles Aluminum Alloy 0001-T6 <br />Aluminum Bolts Aluminum Alloy 2O24T4Anodized <br />Weld filler Materials Aluminum Alloy 535O <br />MISCELLANEOUS RE (bolts, lag screws, nuts) shall be type 3041 or type 3161 stainless steel, and shall be isolated from contact with <br />aluminum with non -conducting sleeves, coatings, or other approved mechanism. <br />CONTACT: Aluminum surfaces in contact with dissimilar materials shall be provided with galvanic separation. All aluminum components in contact with <br />concrete shall be coated with an asphalt -based epoxy, such as "hi -mil sher-tar epoxy" byBhenwin-WiUiama.urapproved equal. <br />WELDING: Conform to AWS D1.2 'Structural Welding Code." Welders shall be certified in accordance with AWS requirements. When fillet weld size is <br />not indicated, provide maximum weld size of the material thickness in accordance with the latest edition of the "Aluminum Design Manual" by the <br />aluminum association. <br />WOOD FRAMING <br />REFERENCE STANDARDS: Conform to: <br />(1) IBC Chapter 23"W0UD�^ <br />(2) NDSand WUSSupplement ' "National Design SpecifiouUunfor Wood ConuhuoUon.^ <br />ALTERNATES: Alternates for specified item may bosubmitted to the FOR for review. Contractor shall submit ocurrent |CC-E3R/IA M0-ERmpurt <br />identifying that an alternative component has the same or greater load capacity than the specified item. <br />IDENTIFICATION: All sawn lumber and pro -manufactured wood products shall be identified by the grade mark or a certificate of inspection issued by the <br />certifying agency. <br />Sawn Lumber: Conform to grading rules of WWPA,WCLIB'mNLGA. Finger jointed studs acceptable at interior non-structural walls only. <br />Member Use Size Species Grade <br />Studs &Plates 2x4.3x4.2x6.3x8 HE No.2 <br />Posts 4x4.4x8'4x8 HE No.2 <br />Joists 2m8-2x12 DF Nn.2 <br />Beams 4x8-4x12 DF No.2 <br />8ouma 8x8-6x12 DF No. 1 <br />Posts 8x8.8x8 DF Nu.i <br />Wood Structural Sheathing (PI)Tood): Wood APA rated structural sheathing includes: all veneer plywood, oriented strand board, waferboard, <br />particleboard, T1-11siding, ondmompoeihenofvonoorundwuodbmuedmatehoiConfbnnboPmduct8tandmrduPS4-06ondPS-2-82ufiheU.G.Dapt. <br />ufCommerce and the American Plywood Association (APA) <br />ExposureMinimum APA Rating <br />Floor 23/32''T&G 24OC 0und'|'F|nor 1 <br />Walls 15/32 32/18 (-D 1 <br />Joist Hangers and Connectors: Simpson Strong -Tie Company Inc. auspecified intheir latest catalogs was used umthe basis o[design for this project. <br />Alternate connectors byother manufacturers may bosubstituted provided they have current |CC-EBRIIAPMC-ERapproval for equivalent orgreater load <br />capacities and are reviewed and approved by the EOR prior to ordering. Connectors shall be installed per the manufacturer's instructions. Where <br />connector straps connect two members, place 1/2 of the nails or bolts in each member. Nail straps to wood framing as late as possible in the framing <br />process toallow the wood 0ushrink and the building bosettle. <br />Nails and Staples: Conform boIBC See 23O3.8"Nails and Stup|no.^Unless noted onplans, nail per IBC Table %3O4.iO.1.Unless noted otherwise all <br />nails shall be common. Nail sizes specified on the drawings are based on the following specifications: <br />COMMON NAILS <br />Size Length Diameter <br />8d 2-1/2" 8131" <br />10d 3" 0j48^ <br />18d 34/2" 0.162" <br />18dSinker 3'114' 8148^ <br />Lag Boits/Thru-Bolts: Conform toASTMA307. Provide plate washers under the heads and nuts of all bolts and lag screws bearing on wood. <br />Engineered Wood Products (EWP): The following materials are based umlumber manufactured byTmo oistbyVVoyorhneumor.TmoJoistby <br />Weyerhaeuser was used as the basis of design for this project. Alternate products by other manufacturers may be substituted provided they have current <br />ICC-ESR/IAPMO-ER approval for equivalent or greater load and stiffness properties and are reviewed and approved by the EOR� <br />a)Parallel : Conform to]CC ESReport No. EG0'1387.CCMCReport No. 111Gi-R.nrNESReport No. NER481.Use <br />2.2E unless noted otherwise. <br />NAILING REQUIREMENTS: Provide minimum nailing in accordance with IBC Table 2304.10.1 "Fastening Schedule" except as noted on the drawings. <br />Nailing for roof/floor diaphragms/shear walls shall be per drawings. Nails shall be driven flush and shall not fracture the surface of sheathing. <br />MOISTURE CONTENT: Wood material used for this project shall have maximum Moisture content of 19% except for the pressure -treated wood sill plate. <br />PRESERVATIVE TREATMENT: Wood materials are required to be "treated wood" under certain conditions in accordance with IBC Sec 2304.12 <br />"Protection against decay and termites." Conform to the appropriate standards of the American Wood -Preservers Association (AWPA) for sawn lumber, <br />glued laminated timber, round poles, wood piles, and marine piles. Follow American Lumber Standards Committee (ALSC) quality assurance <br />procedures. Products shall bear the appropriate mark. <br />METAL CONNECTORS/PT WOOD: All metal hardware and fasteners in contact with pressure treated lumber shall be stainless steel Type 316L. At the <br />Owner's risk and discretion, hot -dipped galvanized metal hardware and fasteners may be investigated for use in lieu of stainless steel provided that the <br />finish has a minimum zinc content of at least 1.85 oz./SF and its use is coordinated by the Contractor and Wood Supplier for the expected environment <br />and moisture exposure for appropriate use based on the method of preservative treatment of the wood. <br />These guidelines outline provide general recommendations for the repair of untreated structural wood frame members that have limited wood decay and <br />deterioration due 0owater infiltration. <br />Temporary Shoring: Any structural framing that isunstable orsuspect ofcollapse shall boshored immediately. Safety ofthe occupants are first priority <br />onthe project site. The contractor iuresponsible for all temporary shoring ufthe structure. <br />Determine the magnitude of decay that penetrates into the structural framing members using a small flathead screwdriver or an awl as a test probe. <br />Expose the wood rot and decay to the fullest extent possible. Structurally competent wood should be resistant to the insertion of the tool- <br />RemoveaUdaoayfrnmthawmodhnmingnrobmdum|member. <br />yymxd Treatment: All structural framing that has had decay removed or has been exposed to significant moisture (with a moisture content above 19%) or <br />ixounandywet should hatreated for both 1.one-time surface growth cleaner and 2.iolimit future growth. Agood surface treatment cleaner Vokill <br />surface growth should include a 50/50 wateribleach mixture that is spray or roller applied. Asecond treatment for alonger-term fungicide and growth <br />inhibitor should then beapplied. A wood preservative treatment such as the Woodlife Coppercoat should be generously applied by brush or roller in <br />accordance with the recommendations o/the manufacturer. <br />Surface Growth: Framing members that have not experienced decay and are structural competent based upon test probing, but exhibit surface growth <br />may remain in place provided that the mold is removed through chemical treatment. <br />Replacement: Framing members that require removal and replacement based on the criteria below shall be replaced with new wood framing per the <br />WOOD FRAMING section ofthe General Structural Notes. Framing with exterior exposure andlor in contact with concrete shall be pressure -treated. All <br />metal hardware and fasteners in contact with pressure treated lumber be stainless steel Type 316L. A1the Owner's risk and discretion, hot -dipped <br />galvanized metal hardware and fasteners may be investigated for use in lieu of stainless steel provided that the finish has a minimum zinc content of at <br />least 1.85 oz. /SF and its use is coordinated by the Contractor and Wood Supplier for the expected environment and moisture exposure for appropriate <br />use based onthe method ufpreservative treatment ofthe wood. <br />Special Cddiunu:VVhamquestionauhummgardingthao*ten1ofdetehomUonurthomiUya\ion.theotmctum|E8Rwi||mokethefina|determinoUon. <br />For unique conditions and areas of significant deterioration the structural EOR is to be contacted to assist in generating detailed recommendations. <br />Project and Framing Specific Recommendations <br />Studs <br />Minor deterioration on the surface of the stud (up to 3/16" deep) will require removal of the surface rot through a mechanical effort treated with an <br />appropriate fungicide and with a wood preservative. The addition of a matching stud nailed alongside (sistered) with 1 Od (0.148"-diameter x 3"-Iong) <br />common nails @ 12" oc. may be necessary to achieve a plumb surface for proper nailing of sheathing and wallboard. <br />Significant deterioration to the stud (more than 3/16" deep by up to one -quarter of its length) requires sistering or the removal and replacement ofthe <br />deteriorated stud. All abutting framing, whether wet or not is to be treated with an approved wood preservative. All studs with significant deterioration at <br />ho|duwnomust hobeaddressed bythe structural EO8onooase'by-naoebasis. <br />Top d Bottom Plates <br />Replace all plates at bearing walls and/or shearwalls which show signs of deterioration with new material. All framing lumber in contact with concrete <br />shall boreplaced with treated framing with onapproved wood preservative. The degree ofvisible deterioration alone should not determine whether e <br />plate is to be replaced since the plate can trap water between surfaces where it is not readily visible. If decay is suspected, subsurface explorations <br />should beperformed, orthe plate should heremoved and replaced. <br />Splice Sill plates to concrete by butting members together and strapping across the joint with a Simpson LSTA-94 strap. Provide a minimum of two 5/8" <br />diameter anchor bolts ineach section ofthe bottom plate. Provide one bolt within 12" of each end of the sill plate and provide a maximum bolt spacing <br />of48''oncenter. . Anacceptable retrofit anchor bolt ioo50^'diametarx8^-|nogSimpson T|TEMHDwith a3x3plate washer. Site apeoifiuconditions <br />should boreviewed bythe structural EOR. <br />that are replaced are to be strapped to adjacent plates with a minimum Simpson LSTA24. Stagger the splice <br />kmai'cr nfthe double top plates. New sections of top and bottom plates should be plate nailed to the rim joist with 16d (0.161 "-diameter x 3.5%long) <br />nails at4^(ninhnum.ortomatch existing) oncenter. Site specific conditions should hareviewed bythe structural B]R- <br />Perimeter Headers and Rim Joists <br />Minor deterioration on the surface of the rim joist or header (up to 3/16" deep) will require removal of the deteriorated portions, treating the retained <br />material with a fungicide, an approved wood preservative and infilling the voids as required. <br />Significant deterioration to the rim joist or header (more than 3/16" into any surface) requires removal and replacement of the deteriorated member. <br />Refer Nthe structural plan for replacement members. Consult the structural EORfor specific cases with limited area. All abutting framing, whether wet <br />or not is to be treated with an approved wood preservative. New section of rim joist should be plate nailed to the at the top and bottom plates with 16d <br />(0jGf'-dimmeterx3.6^'|ong)nails ei4^(minimum.or\umatch existing) oncenter. <br />Solid Sawn Floor Joists and Beams <br />Minor nnthe surface ofthe joist orbeam (up to3/iG^deep) will require removal ofthe deteriorated portions, treating the retained material <br />with a fungicide, an approved wood preservative and infilling the voids as required. <br />Significant deterioration to the joist or beam (more than 3/16" into any surface) requires removal and replacement of the deteriorated member. Referto <br />the structural plan for replacement members. Consult the structural FOR for specific cases with limited area. All abutting framing, whether wet or not is <br />hobetreated with anapproved wood preservative. <br />Deteriorated Fland Roof Sheathing shall be removed and replaced in minimum 4-ft x 4-ft sections, Provide blocking at new sheathing edges, and nail <br />both new and existing sheathing tothe blocking. Nail sheathing with 8d (OA 31 "-diameter x 2.5"-Iong) nails at 6" on center at all edges and 12" on center <br />atfield framing. <br />Deteriorated Wall Shathin shall beremoved and replaced inminimum 4-ftx44tsections. The new and existing sheathing shall benailed konew <br />blocking atall panel edges tomatch the stud depth atthe sheathing edges. Nail plywood sheathing with 1Ud(U.148''-diameterx3^'|ong)common <br />shaurwaHsheathing nails, tomatch existing nail size and spacing. Where sheathing edge nail spacing cannot be determined from existing drawings or <br />existing conditions, use at minimum 10d common nails at 3" on center for floors I and 2, and 10d common nails at 4" on center for floors 3 and 4. <br />DENSGLAS INSTALLATION <br />° Maximum framing spacing 24^uo <br />m Minimum 2xframing <br />w May boinstalled parallel orperpendicular tothe studs <br />m Fastener spacing 4^0001panel edges and 8^ooinfield. <br />° Nails: 8dcooler nails (0.8O2^diameter x1-70^long with i/4^head) <br />• Fasteners shall bodriven flush with the panel surface (not countersunk) and into the framing system. <br />m Locate fasteners mtleast 3/8^from the ends and edges ofthe sheathing. <br />w Install sheathing with end joints staggered when installing panels horizontally. <br />m Ends and edges x[the sheathing should fit tightly. <br />#4 x 26^ 8D 16^OC WV <br />EMBED INTO ([) CUNC SLAB W/ <br />/Nl 41/^ SLAB -ON -GRADE <br />W/ 6x6 - W14xW1.4 WWF <br />LSUAB <br />(MATCH EXIST) <br />«4 x 261 DOWEL WV 4^ EMBED INTO <br />ff <br />(F) FOUNDATION W/ EPDXY @ 18^OC <br />(E) SLAB -ON -GRADE <br />TO REMAIN <br />4^ EMBED <br />um/x <br />NEW S)LAB/ , EXISTING SLAB/ <br />FOUNDATION FOUNDATION <br />° <br />4^ <br />EMBED <br />^ <br />(E) SLAB -ON -GRADE <br />WHERE OCCURS <br />/E\ STEM WALL & FOOTING <br />