My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10 SE EVERETT MALL WAY 2022 HASHTAG CANNABIS Plans 2022-12-15
>
Address Records
>
SE EVERETT MALL WAY
>
10
>
HASHTAG CANNABIS
>
Plans
>
10 SE EVERETT MALL WAY 2022 HASHTAG CANNABIS Plans 2022-12-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2022 11:32:49 AM
Creation date
12/15/2022 11:21:11 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
10
Tenant Name
HASHTAG CANNABIS
Permit
B2202-024
Year
2022
Notes
NEW RETAIL CANNABIS SHOP W/ ASSOCIATED EMPLOYEE AREA
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br />1. PROVIDE P-LAM UP TO 4'-0" ON ALL <br />WALLS WITH J-MOULD AT TOP TRIM <br />2. RESROOM FLOOR TO BE SHEET VINYL <br />WITH 6" INTEGRATED COVE BASE WITH 3/8" <br />MIN. RADIUS <br />3. MAXIMIM REACH DEPTH AND HEIGHT PER <br />ICC TABLE 606.7 <br />39"-41 " <br />12" <br />-36" GRAB BAR <br />-42" GRAB BAR <br />2�LM I N. 18" VERTICAL GRAB BAR <br />24" MIN <br />,-TOILET PAPER DISPENSER <br />603 TOILET AND BATHING ROOMS: <br />1. <br />603.2.1 TURNING SPACE: A TURNING SPACE COMPLYING WITH 304 <br />7. 604.2 LOCATION: THE WATER CLOSET SHALL BE <br />LOCATED WITH A <br />SHALL BE PROVIDED WITHIN THE ROOM <br />WALL OR PARTITION TO THE REAR AND TO ONE <br />SIDE. THE <br />CENTERLINE OF THE WATER CLOSET SHALL BE <br />16 INCHES MINIMUM <br />2, <br />603.2.2 OVERLAP: CLEAR =LOOR SPACES, CLEARANCES AT FIXTURES, <br />TO 18 INCHES MAXIMUM FROM THE SIDE WALL <br />OR PARTITION. WATER <br />AND TURNING SPACES SHALL BE PERMITTED TO OVERLAP <br />CLOSETS LOCATED IN AMBULATORY ACCESSIBLE <br />COMPARTMENTS <br />SPECIFIED IN SECTION 604.9 SHALL HAVE THE <br />CENTERLINE OF THE <br />WATER CLOSET 17 INCHES MIN. TO 19 INCHES <br />MAX. FROM THE SIDE <br />3. <br />603.2.3 DOOR SWING: DOORS SHALL NOT SWING INTO THE CLEAR <br />WALL OR PARTITION <br />FLOOR SPACE OR CLEARANCE FOR ANY FIXTURE. <br />604.3 CLEARANCE: <br />EXCEPTIONS: <br />1. DOORS TO A TOILET AND BATHING ROOM <br />r <br />R E S T R❑❑ M R E C X I S T I i V lJ <br />FOR A SINGLE OCCUPANT, ACCESSED ONLY THROUGH A <br />8. 604.3.1 SIZE: A CLEARANCE AROUND A WATER <br />CLOSET 60 INCHES <br />PRIVATE OFFICE AND NOT FOR COMMON USE OR PUBLIC <br />MINIMUM, MEASURED PERPENDICULAR FROM THE <br />SIDEWALL, AND 56 <br />DETAILS <br />PROVIDED <br />F- ❑ <br />R <br />REPAIR <br />A N D VERIFICATION <br />ONLY <br />USE <br />FLOORHALL SPACBE PRO`✓IDEDDTHOE SSWINGWING OF OTHTHEF DOORACAN <br />SHALES BEI PROVIDEDRED PERPENDICULAR FROM <br />THE REAR WALL, <br />SOAP <br />DISPENSER <br />MIRROR <br />x Q V r Q <br />W.G. o <br />r INSULATE N-75 <br />12" MAX n SINK PIPES <br />FLOOR MOUNT TOILET PAPER SEAT COVER URINAL LAVATORY <br />TOILET DISPENSER DISPENSER <br />1 - MOUNTINGHEIGHTS <br />SCALE: INTO <br />A. <br />39"-41" MIN <br />12" MAX <br />42" MIN. <br />24" MIN <br />B. L � <br />1-1/4" - 2"-� <br />MAX PER ICC <br />GRAB BAR SECTION <br />609.2.1 <br />3'--0" MIN <br />C. <br />MIN. MIN. <br />W.C. <br />18" VERTICAL <br />GRAB BAR <br />LQ <br />o <br />o <br />I Q0 AI <br />o' 0 <br />I (_0 <br />Q <br />GRAB BARS PER ICC 604.5 <br />FLUSH HANDLE 0-) SEE 10/A6.02 BACKING <br />ON WIDE SIDE co DETAIL <br />OF STALL OR <br />ROOM U <br />TOILET el6"-18"./e iACESSIBLE PER ICC 604.2 <br />17"-19" - AMBULATORY PER ICC 604.2 <br />1, 604.5.1 FIXED SIDE WALL GRAB BARS: FIXZED SIDEWALL GRAB <br />BARS SHALL BE 42 INCHES MIN. IN LENGTH, LOCATED 12 INCHES <br />MAX. FROM THE REAR WALL AND EXTENDING 54 INCHES MIN. <br />FROM THE REAR WALL. IN ADDITION, A VERTICAL GRAB BAR 18 <br />INCHES MIN. IN LENGTH SHALL BE MOUNTED WITH THE BOTTOM <br />OF THE BAR LOCATED BETWEEN 39 INCHES ABD 41 INCHES <br />ABOVE THE FLOOR, AND WITH THE CENTER LINE OF THE BAR <br />LOCATED BETWEEN 39 INCHES AND 41 INCHES FROM THE REAR <br />WALL <br />?. 604-5-2 REAR WAI I GRAR RARS- THE REAR WAI I GRAB PAR <br />SHALL BE 36" MIN. IN LENGTH, AND EXTEND FROM THE <br />CENTERLINE OF THE WATER CLOSET 12 INCHES MIN. ON THE SIDE <br />CLOSEST TO THE WALL, AND 24 INCHES MIN. ON THE TRANSFER <br />SIDE <br />3 609.1 GENERAL: GRAB BARS IN ACCESSIBLE TOILET OR BATHING <br />FACILITIES SHALL COMPLY WITH SECTION 609. <br />4. 609.2.1 CIRCULAR CROSS SECTION: GRAB BARS WITH A CIRCULAR <br />CROSS SECTION SHALL HAVE AN OUTSODE DIAMETER OF 1-1/4" <br />MIN. AND 2 INCHES MAX. <br />5. 609.2.2 NON -CIRCULAR CROSS SECTION: GRAB BARS WITH A NON <br />CIRCULAR CROSS SECTION SHALL HAVE A CROSS SECTION <br />DIMENSION OF 2 INCHES MAX. AND A PERIMETER DIMENSION OF 4 <br />INCHES MIN. AND 4.8 INCHES MAX. <br />6. 609.2.3 SPACING: THE SPACE BETWEEN THE WALL AND THE GRAB <br />BAR SHALL BE 1-1/2". THE SPACE BETWEEN THE GRAB BAR AND <br />PROJECTING OBJECTS BELOW AND AT THE ENDS OF THE GRAB <br />BAR SHALL BE 1-1/2" MIN. THE SPACE BETWEEN THE GRAB BAR <br />AND PROJECTING OBJECTS ABOVE THE GRAB BAR SHALL BE 12" <br />MIN. <br />7. 609.4 POSITION OF GRAB BARS: GRAB BARS SHALL BE INSTALLED IN <br />A HORIZONTAL POSITION, 33 INCHES MIN. AND 36 INCHES MAX. ABOVE <br />THE FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. AT <br />WATER CLOSETS PRIMARILY FOR CHILDRENS USE COMPLYING WITH <br />SECTION 604.10, GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL <br />POSITION 18" MIN. AND 27" MAX ABOVE THE FLOOR MEASURED TO <br />THE TOP OF THE GRIPPING SURFACE <br />8. 609.5 SURFACE HAZARDS: GRAB BARS, AND ANY WALL OR OTHER <br />SURFACES ADJACENT TO GRAB BARS, SHALL BE FREE OF SHARP OR <br />ABRASIVE ELEMENTS. EDGES SHALL BE ROUNDED <br />9. 609.6 FITTINGS: GRAB BARS SHALL NOT ROTATE WITHIN THIER FITTINGS <br />DISPENSER/ NAPKIN/ NAPKIN/ <br />WASTE TAMPON TAMPON <br />RECEPTACLE DISPENSER DISPOSAL ROBE HOOKS <br />MIRROR (SAFETY GLAZING) <br />LEVER VALVE <br />BE REVERSED TO MEET SECTION 603.2.3 <br />8. 604.3.2 OVERLAP: THE REQUIRED CLEARANCE AROUND THE HATER <br />2. WHERE THE ROOM IS FOR INDIVIDUAL USE AND A <br />CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, <br />CLEAR FLOOR SPACE COMPLYING WITH SECTION 305.3 IS <br />ASSOCIATED GRAB BARS, PAPER DISPENSERS, SANITARY NAPKIN <br />PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE <br />RECEPTACLES, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR <br />DOOR SWING. <br />FLOOR SPACE AT OTHER FIXTURES AND THE TURNING SPACE. NO <br />OTHER FIXTURES OR OBSTRUCTIONS SHALL BE WITHIN THE REQUIRED <br />WATER CLOSET CLEARANCES. <br />4, 603.3 MIRRORS: MIRRORS LOCATED ABOVE LAVATORIES, SINKS OR <br />COUNTERS SHALL BE MOUNTED WITH THE BOTTOM EDGE 40 INCHES <br />9. 604.4 HEIGHT: THE HEIGHT OF WATER CLOSET SEATS SHALL BE 17 <br />MAX. ABOVE THE FLOOR. MIRRORS NOT LOCATED ABOVE LAVATORIES, <br />INCHES MIN, AND 19 INCHES MAX. ABOVE THE FLOOR, MEASURED TO <br />SINKS OR COUNTERS SHALL BE MOUNTED WITH THE BOTTOM EDGE <br />THE TOP OF HTE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN <br />OF THE REFLECTING SURFACE 35 INCHES MAX. ABOVE THE FLOOR <br />TO A LIFTED POSITION. <br />5. 603.4 COAT HOOKS AND SHELVES: COAT HOOKS SHALL BE LOCATED <br />WITHIN ONE OF THE REACH RABGES SPECIFIED IN SECTION 308, <br />SHELVES SHALL BE 40 INCHES MIN. AND 48 INCHES MAX. ABOVE <br />THE FLOOR. <br />6. 604.1 GENERAL: ACCESSIBLE WATER CLOSETS AND TOILET <br />COMPARTMENTS SHALL COMPLY WITH SECTION 604. COMPARTMENTS <br />CONTAINING MORE THAN ONE PLUMBING FIXTURE SHALL COMPLY WITH <br />SECTION 603. WHEELCHAIR ACCESSIBLE COMPARTMENTS SHALL <br />COMPLY WITH SECTION 604 8. AMBULATORY ACCESSIBLE <br />A. <br />FINISH FLOOR LEVEL <br />THRESHOLD <br />N x <br />�� <br />B. <br />x N x <br />\< �< <br />1. INTERIOR AND EXTERIOR THRESHOLDS SHALL BE NO <br />HIGHER THAN 1 /2 INCH ABOVE THE ADJACENT Fl OOR <br />LEVELS. EACH EXPOSED EDGE OF THRESHOLDS SHALL <br />BE BEVELED OR SLOPED AT AN ANGLE NOT TO <br />EXCEED 45 DEGREES SO THAT NO VERTICAL <br />CHANGE OF ELEVATION EXCEEDS 1 /4 INCH. <br />COMPARTMENTS SHALL COMPLY WITH SECTION 604.9 0THRESHOLDS <br />SCALE: NITS <br />PROTECTED PIPING 1MIN. <br />__ <br />ICC 606.E AX <br />KNEE CLEARANCE <br />PER ICCM1306.2.4 <br />NOTES:' <br />1. TOE CLEARANCE 30" MINIMUM IN WIDTH PER ICC '117.1 306.2.5 <br />2. KNEE CLEARANCE 30" MINIMUM IN WIDTH PER ICC 117.1 306.3.5 <br />3. CONTRASTING COLOR BETWEEN COUNTER TOP AND FLOORING <br />4. CLEAR KNEE SPACE TO BE 29" AFF MIN. <br />5. PER ICC 306.3.4 CLEARANCE REDUCTION. BETWEEN 9" AND 27" ABOVE THE <br />FLOOR, HTE KNEE CLEARANCE SHALL BE PERMITTED TO BE REDUCED AT A RATE OF <br />1 " FOR EACH 6" IN HEIGHT <br />SCALE: 3/4" = 1 -0" <br />RESTR❑❑M ARE EXISTING <br />DETAILS PROVIDED FOR REPAIR AND VERIF-ICATI❑N ONLY <br />METAL E <br />1 /4" DIA. <br />SCREWS Tt <br />BLKG. <br />1 1 /4" 1 <br />16 GA. ME <br />W/(1) A35 <br />BOTTOM <br />SHEET VIN' <br />ALL SIDES <br />TABLE 404.2.3.1 MANEUVERING AT MANUAL SWINGING DOORS <br />TYPE OF USE <br />MINIMUM <br />MANEUVERING CLEARANCES <br />APPROACH <br />DIRECTION <br />DOOR <br />SIDE <br />PERPENDICULAR TO <br />DOORWAY <br />PARALLEL TO DOORWAY <br />(BEYOND LATCH UNLESS NOTED) <br />FROM FRONT <br />PULL <br />60 <br />INCHES <br />18 <br />INCHES <br />FROM FRONT <br />PUSH <br />48 <br />INCHES <br />0 <br />INCHES (3) <br />FROM HINGE SIDE <br />PULL <br />60 <br />INCHES <br />36 <br />INCHES <br />FROM HINGE SIDE <br />PULL <br />54 <br />INCHES <br />42 <br />INCHES <br />FROM HINGE SIDE <br />PUSH <br />42 <br />INCHES <br />(1) <br />22 <br />INCHES (3 4) <br />FROM LATCH SIDE <br />PULL <br />48 <br />INCHES <br />(2) <br />24 <br />INCHES <br />FROM LATCH SIDE <br />PUSH <br />42 <br />INCHES <br />(3) <br />24 <br />INCHES <br />NOTES: <br />1. ADD 6 INCHES IF CLOSER AND LATCH PROVIDED <br />2. ADD 6 INCHES IF CLOSER PROVIDED <br />3. ADD 12 INCHES BEYOND LATCH IF CLOSER AND LATCH PROVIDED <br />4. BEYOND HINGE SIDE <br />32" MIN <br />I� <br />�O <br />(A) HINGED DOOR <br />SCALE: NITS <br />32" MIN. <br />(B) SLIDING DOOR <br />(C) FOLDING DOOR <br />MEN / WOMEN OR UNISEX AS REQUIRED PER PLAN <br />SEE PLAN FOR SIGNAGE LOCATIONS <br />RESTROOM SIGNAGE <br />NOTE: IDENTIFICATION SYMBOLS <br />PER ADA SECT. 4.30 SIGNAGE <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY <br />PER ICC ANSI 1 17.1-2003 FIG. 703.6.3.1 <br />11 aSIGNAGE <br />36" MIN <br />I <br />> 24" MAX. <br />(D) DOORWAYS <br />WITHOUT DOOR <br />I.C.C. 404 DOORS AND DOORWAYS: <br />404.1 GENERAL. DOORS AND DOORWAYS THAT ARE PART OF AN <br />ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 404. <br />404.2 MANUAL DOORS. MANUAL DOORS AND DOORWAYS AND <br />MANUAL GATES, INCLUDING TICKET GATES, SHALL COMPLY WITH <br />THE REQUIREMENTS OF SECTION 404.2 <br />404.2.1 DOUBLE -LEAF DOORS AND GATES. AT LEAST ONE OF <br />THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL <br />COMPLY WITH SECTIONS 404.2.2 AND 404.2.3 <br />404.2.2 CLEAR WIDTH. DOORWAYS SHALL HAVE A CLEAR <br />OPENING WIDTH OF 32 INCHES MIN. CLEAR OPENING WIDTH OF <br />DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED <br />BETWEEN THE FACE OF TEH DOOR AND STOP, WITH THE DOOR <br />OPEN 90 DEGREES. OPENINGS, DOORS AND DOORWAYS WITHOUT <br />DOORS MORE THAN 24 INCHES IN DELTH SHALL PROVIDE A <br />CLEAR OPENING WIDTH OF 36 INCHES MIN. THERE SHALL BE NO <br />PROJECTIONS INTO THE CLEAR OPENING WIDTH LOWER THAN 34 <br />INCHES ABOVE THE FLOOR. PROJECTIONS INTO THE CLEAR <br />OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE <br />THE FLOOR SHALL NOT EXCEED 4 INCHES. <br />EXCEPTIONS. <br />1. DOOR CLOSERS AND DOOR STOPS SHALL BE <br />PERMITTED TO BE 78 INCHES MIN. ABOVE THE <br />FLOOR <br />2. IN ALTERATIONS. A PROJECTION OF 5/8 INCH <br />MAX. INTO THE REQUIRED CLEAR OPENING WIDTH <br />SHALL BE PERMITTED FOR THE LATCH SIDE STOP, <br />404.2.3.5 FLOOR SURFACE. FLOOR SURFACE WITHIN THE <br />MANEUVERING CLEARANCES SHALL HAVE A SLOPE NOT STEEPER <br />THAN 1:48 AND SHALL COMPLY WITH SECTION 302 <br />404.2.4 THRESHOLDS AT DOORWAYS: IF PROVIDED. THRESHOLD <br />AR DOORWAYS SHALL BE 1/2 INCH MAX. IN HEIGHT. RAISED <br />THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL <br />COMPLY WITH SECTIONS 302 AND 303. <br />1110A SIGNS <br />REQUIRED ACCESSIBLE ELEMENTS SHALL BE IDENTIFIED BY THE INTERNATIONAL <br />SYMBOL OF ACCESSIBILITY AT THE FOLLOWING LOCATIONS <br />7. UNISEX TOILET AND BATHING ROOMS <br />ICC ANSI 117.1 <br />703.5 PICTOGRAMS. <br />703.5.1 GENERAL. PICTOGRAMS SHALL COMPLY WITH SECTION 703.5 <br />703.5.2 PICTOGRAM FIELD. PICTOGRAMS SHALL HAVE A 6 INCH FIELD MIN. IN HEIGHT. <br />CHARACTERS OR BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD. <br />703.5.3 FINISH AND CONTRAST. PICTOGRAMS AND THEIR FIELDS SHALL HAVE ANON <br />GLARE FINISH. PICTOGF;AMS SHALL CONTRAST WITH THEIR FIELDS, WITH EITHER A <br />LIGHT PICTOGRAM ON A. DARK FIELD OR A DARK PICTOGRAM ON A LIGHT FIELD. <br />703.5.4 TEXT DESCIPTORS. WHERE TEXT DESCRIPTOR ARE REQUIRED, THEY SHALL BE <br />LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. TEXT DESCIPTORS SHALL COMPLY <br />WITH SECTIONS 703.3 AND 703.4 <br />703.6 SYMBOLS OF ACCESSIBILITY <br />703.5.1 GENERAL. SYMBOLS OF ACCESSIBILITY SHALL COMPLY WITH SECTION 703.6 <br />703.6.2 FINISH AND CONTRAST. SYMBOLS OF ACCESSIBILITY THEIR FIELDS SHALL <br />HAVE A NON GLARE FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WITH <br />THEIR FIELDS, WITH EITHER A LIGHT SYMBOL ON A DARK FIELD OR A DARK SYMBOL <br />ON A LIGHT FIELD. <br />IBC 1101.2.6 WASHING -ION STATE AMENDMENTS <br />(ICC A117.1 SECTION 703.6.3.1. INTERNATIONAL SYMBOL eV A I TL4 .)AREA <br />WHERE THE INTERNATIONAL SYMBOL OF ACCESSIBILIT IS REQUIRED, IT SHALL BE <br />PROPORTIONED COMPLYING WITH ICC All 17.1 FIGURE 7C 3.6.3.1. ALL INTERIOR AND <br />EXTERIOR SIGNS DEPICTING THE INTERNATIONAL SYMB DL OF ACCESSIBILITY SHALL BE <br />WHITE ON A BLUE BACK GROUND <br />m <br />w <br />0 <br />cv <br />Cv <br />0 <br />�o <br />t... <br />�U <br />a <br />f <br />a <br />O w <br />N i <br />N � <br />aT <br />U � <br />v `o <br />Uo <br />O <br />� I <br />z <br />0 <br />w I- <br />CD 0 <br />00 L- <br />0 o-) m <br />lZCD <br />1co <br />I <br />SCALE:NTS <br />SCALE: 3 " W V-0" <br />SCALE:NTS <br />
The URL can be used to link to this page
Your browser does not support the video tag.