Laserfiche WebLink
LEASE LINE <br />CONSTRUCTION TO <br />-- — BE DEMOLISHED <br />EXISTING WALLS <br />EXISTING FULL HEIGHT <br />GLASS <br />3-PVC30-AD100-REV00 <br />1. LEASE LINE; G.C. TO VERIFY ACTUAL MEASUREMENTS AND REPORT ANY DISCREPANCIES <br />IMMEDIATELY. <br />2. EXISTING STOREFRONT DOORS, GLAZING ASSEMBLY & FRAMING TO REMAIN. CLEAN AND <br />RENDER TO "LIKE NEW". <br />3. EXISTING SIGN HAS BEEN REMOVED AND DIS <br />CARDED, EXISTING BRICK ON LLD FACADE TO BE <br />RESTORED AT ORIGINAL CONDITION, AS REQUIRED PER LANDLORD APPROVAL. SEE A300 SHEET <br />FOR MORE INFORMATION. <br />4. REMOVE EXISTING FLOORING AND BASE. PATCH AND REPAIR SUB -FLOOR TO ORIGINAL <br />CONDITION AND RE -SEAL ALL FLOOR PENETRATIONS. PREP FOR NEW FINISHES. <br />5. EXISTING PERIMETER WALLS TO REMAIN. PROTECT IN PLACE AND KEEP INTACT ANY EXISTING <br />FIRE RATINGS. PREPARE ALL EXISTING SURFACES TO RECEIVE NEW FINISHES AS REQUIRED AND <br />BRING TO A LEVEL 4 FINISH WHERE APPLICABLE. REMOVE EXISTING ELECTRICAL OUTLETS AND <br />PATCH AND REPAIR WALL. <br />6. EXISTING PLUMBING FIXTURES, ACCESSORIES, AND ANY FLOOR DRAINS TO BE REMOVED, U.N.O. <br />WASTE AND VENT LINES BELOW FLOOR SHALL BE CAPPED BELOW FLOOR LEVEL AND <br />ABANDONED. VENT PIPING ABOVE FLOOR SHALL BE REMOVED. PLUS ANY ADDITIONAL <br />DEMOLITION AND REMOVAL AS IS NECESSARY FOR INSTALLATION OF NEW WORK <br />COORDINATE WITH PLUMBING PLANS. <br />7. EXISTING DOOR AND HARDWARE TO BE REMOVED. <br />8. ALL PREVIOUS TENANTS CASEWORK AND FURNITURE HAVE BEEN REMOVED. REMOVE EXISTING <br />ELECTRICAL & DATA HOOK-UP FROM PREVIOUS TENANTS CASEWORK AND FURNITURE, <br />REMOVE WIRING AND CONDUCT BACK TO SOURCE. <br />9. EXISTING TOILET ROOM TO REMAIN. PLUMBING FIXTURES TO BE TEMPORARILY REMOVED <br />DURING CONSTRUCTION OF NEW FINISHES AND REINSTALLED. CLEAN AND RENDER TO "LIKE <br />NEW" CONDITION. COORDINATE WITH NEXTORE PM IF ANY FIXTURES ARE IN POOR <br />CONDITION. <br />10. EXISTING ELECTRICAL PANEL LOCATIONS. REFER TO ELECTRICAL SHEETS FOR MORE <br />INFORMATION ON THE EXTENT OF DEMO AND NEW WORK. <br />11. EXISTING SECURITY SHUTTERS TO REMAIN, G.C. TO CONFIRM IN WORKING ORDER, TAKE DOWN <br />AND PUT BACK IN PLACE FOLLOWING COMPLETED ADJACENT FINISHES. <br />12. EXISTING PARTITIONS SHOWN DASHED ARE TO BE REMOVED AND DISCARDED. <br />13. EXISTING CEILING THROUGHOUT THE SPACE TO BE DEMOLISHED AND REMOVED, INCLUDING <br />ALL EXISTING LIGHTING, DIFFUSERS AND ALL OTHER CEILING RELATED ITEMS. <br />14. EXISTING REAR DOOR TO REMAIN. CLEAN AND RENDER TO 'LIKE NEW'. INSPECT HARDWARE TO <br />ENSURE IN GOOD AND WORKING CONDITION. COORDINATE WITH NEXTORE PM IF <br />REPLACEMENT IS NECESSARY. <br />15. G.C. TO OPEN WALL AS NEEDED FOR PLUMBING AND ELECTRICAL NEEDED FOR PEARLS VISION <br />BUILD OUT. PATCH AND REPAIR WALL, KEEP IN TACT EXISTING FIRE RATINGS AND PREPARE ALL <br />SURFACES TO RECEIVE NEW FINISHES AS REQUIRED AND BRING TO LEVEL 4 FINISH. <br />16. EXISTING CEILING TO REMAIN. REMOVE EXISTING LIGHTING AND REPLACE WITH NEW. SEE <br />MECHANICAL SHEETS FOR MORE INFORMATION ON THE EXTENT OF DEMO AND NEW WORK <br />FOR THE EXHAUST. <br />17. OPEN EXISTING WALL TO PROVIDE PROPER BLOCKING FOR THE NEW VERTICAL GRAB BAR. <br />ENSURE BLOCKING IS THERE FOR ALL GRAB BARS. SEE SHEET A203 FOR GRAB BAR <br />INSTALLATION DETAILS. PATCH AND REPAIR WALL, KEEP INTACT EXISTING FIRE RATINGS AND <br />PREPARE ALL SURFACES TO RECEIVE NEW FINISHES AS REQUIRED AND BRING TO LEVEL 4 <br />FINISH. <br />18. EXISTING LIGHTS TO REMAIN. G.C. TO RE -LAMP. <br />19. EXISTING ACT CEILING AND LIGHTING TO REMAIN. G.C. TO RE -LAMP. REPLACE ANY TILES THAT <br />ARE DAMAGED. <br />20. REMOVE EXISTING GYP. BD. (SIDE WITH ARROW POINTING TO IT) IN ORDER TO PROVIDE BATT <br />INSULATION WITHIN EXISTING WALL. REPLACE GYP. BD. AND BRING UP TO A LEVEL 4 FINISH. <br />21. REMOVE EXISTING GYP. BD. (SIDE WITH ARROW POINTING TO IT) IN ORDER TO PROVIDE NEW <br />PLUMBING FOR DRINKING FOUNTAINS. REPLACE WITH M.R. GYP. BD. AND BRING UP TO A LEVEL <br />4 FINISH. <br />2-PVC30-AD100-REV00 <br />A. THE G.C. SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC AND/OR WORKMEN ON <br />THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON ON, ABOUT, OR ADJACENT TO THE PREMISES. THE <br />G.C. SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES, RULES AND REGULATIONS RELATIVE TO SAFETY AND THE <br />PREVENTION OF ACCIDENTS. <br />B. THIS DEMO <br />LITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF WORKING DRAWINGS. DO NOT <br />REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING AND COORDINATING WITH ALL GENERAL TRADES AS TO HOW <br />THEY RELATE TO THE OVERALL PROJECT. <br />C. THE G.C. SHALL BE RESPONSIBLE FOR REMOVING OR DEMOLISHING EXISTING CONSTRUCTION WHICH WILL INTERFERE <br />WITH THEIR NEW WORK AND ANY TEMPORARY BRACING OR PERMANENT SUPPORT STRUCTURES. <br />D. WHEN EXISTING ELECTRICAL SERVICE, POWER, AND LIGHTING IS REMOVED, STUB BACK AND CAP AS REQUIRED IN <br />AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK. <br />E. EXISTING EXPOSED CONCRETE THROUGHOUT. CAP EXISTING MECHANICAL, PLUMBING AND ELECTRICAL SERVICES <br />FLUSH WITH EXISTING SLAB AS REQUIRED, TYPICAL THROUGHOUT,- REFER TO RESPONSIBILITY SCHEDULE ON G002 FOR <br />FLOORING PREPARATION, <br />F. AT THE G.C.'S OPTION, DEMOLISH OR REMOVE MORE OR LESS EXISTING WORK, PROVIDED THAT SUCH VARIATION WILL <br />EXPEDITE THE PROJECT AND NOT INCREASE THE EXPENSE TO THE OWNER OR VIOLATE ANY CODES. THESE OPTIONS <br />SHALL BE SUBJECT TO THE NEXTORE'S PROJECT MANAGER'S APPROVAL. <br />G. COORDINATE ANY SYSTEMS SHUTDOWNS WITH LANDLORD & INCLUDE COSTS OF SHUTDOWN IN THE BID. <br />H. EXCEPT AS NOTED, G.C. SHALL INCLUDE COSTS TO CUT, PATCH AND/OR REPAIR EXISTING WORK AND EXISTING <br />FACILITIES WHICH MAY BE DISTURBED DURING INSTALLATION OF NEW WORK IN BID PACKAGES. <br />I. IN ACCORDANCE WITH THE DRAWINGS, THOSE ITEMS WHICH ARE REMOVED, AND ARE NOT RELOCATED OR REUSED, <br />SHALL BE DISPOSED OF BY THE G.C. <br />J. EXISTING STOREFRONT SIGNAGE HAS BEEN REMOVED; G.C. TO COORDINATE ELECTRICAL SERVICE W/ NEW <br />STOREFRONT SIGNAGE. PATCH AND REPAIR STOREFRONT SUBSTRATE AS REQUIRED. <br />K. REMOVE ALL WALL VINYL FROM WALLS (AS REQUIRED) AND PREP WALLS FOR NEW FINISHES <br />L. G.C. TO INSPECT ALL EXISTING WALLS TO REMAIN AND ENSURE THAT THEY ARE UP TO CURRENT SPECIFICATIONS AND <br />BROUGHT TO A LEVEL 4 FINISH WHERE APPLICABLE. <br />101-0 1/2" 01 53'-41/4" LEASE LINE 01 <br />I <br />5 <br />15 <br />TYP. <br />I I I <br />I I II <br />1 I <br />15 <br />5 II <br />N <br />TYP. <br />II I <br />I I <br />I I <br />I I <br />I <br />I � ( <br />I 1 <br />I I <br />I III <br />II <br />I I I <br />i II <br />I I <br />I <br />II <br />10 2 TYP. <br />I I <br />I II <br />12 <br />II <br />14 18 4 <br />' II <br />I <br />5 13 <br />TYP. <br />Li <br />12 II <br />I 1 <br />II <br />4 <br />II <br />II 8 <br />I I <br />I I 1301 <br />� <br />X II 3 <br />W I <br />I <br />II <br />20 I <br />1 O 2 TYR <br />_ A <br />I I <br />\ / \ <br />O\ \\-------- ----- ------------------------------------ O\ \\ <br />I I I <br />N ICI <br />II i II <br />12 <br />I li 2 <br />! O II <br />14 4 <br />13 I j <br />O\ 11 <br />5 21 \ \ L <br />O/i <br />TYP. I <br />I <br />III. <br />I II <br />\ III <br />� I I <br />4 9 4 20 2 I <br />16 19 TYP. <br />O TYP. <br />17 <br />63'-4 3/4" 01 <br />DEMOLITION PLAN - <br />SCALE: 114" = T-0 <br />M. G.C. TO PROVIDE AND INSTALL TEMPORARY WINDOW GRAPHICS TO ACT AS CONSTRUCTION BARRICADE. <br />COORDINATE REQUIREMENTS WITH LANDLORD. <br />N fEME)\+All INTERIG)I (Af 1G AND lA\RIN IA T/HlIAI IA ALL <br />AREAS. <br />0. PRIOR TO INSTALLATION <br />O OF NEW FLOOR GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE IN <br />COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AN S O D THE LATEST EDITION OF TILE COUNCIL OF AMERICA. IF <br />THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO INSTALLATION. <br />P. TEMPORARY BARRICADE <br />• TEMPORARY BARRICADE SHALL BE CONSTRUCTED PER LLD REQUIREMENTS: <br />THE BARRICADE SHALL BE ENCLOSED AT THE TOP WITH 6 MILLIMETER OR THICKER PLASTIC SHEETING AND DUST-POOF <br />WITH 6" VINYL COVE BASE. IF A DOOR IS LOCATED IN THE MIDDLE OF THE BARRICADE, THERE MUST ALSO BE A DOOR <br />FRAME. CONSTRUCTION SHALL BE OF STUDS WITH TAPED, SPACKLED AND PAINTED GYPSUM BOARD TO THE <br />PUBLIC SIDE. PAINT COLOR IS TO BE DETERMINED BY MALL MANAGEMENT, MALL GRAPHICS WILL BE INSTALLED BY <br />LANDLORD AND SHALL BE REIMBURSED BY CONTRACTOR AT PRE -CONSTRUCTION MEETING. BARRICADE SHALL <br />NOT EXTEND MORE THAN 3'-0" BEYOND THE LEASE LINE. <br />• TEMPORARY BARRICADE IS TO BE 100% COMPLETE AND READY FOR GRAPHICS TO BE INSTALLED NO MORE THAN (2) <br />DAYS AFTER CONSTRUCTION START. G.C. TO CONTACT OWNER'S REPRESENTATIVE UPON COMPLETION TO <br />COORDINATE GRAPHICS INSTALLATION, TEMPORARY BARRICADE MUST BE PRIMED AND PAINTED WITH (2) COATS OF <br />EITHER EGGSHELL OR SEMI -GLOSS FINISH ONLY. <br />• GC IS RESPONSIBLE FOR MAINTAINING BARRICADE DURING CONSTRUCTION. <br />• REMOVE BARRICADE WHEN 100% OF STOREFRONT OR JOB IS COMPLETED ON THE EVENING BEFORE G.C.'S PUNCHLIST <br />IS COMPLETED, PRIOR TO OWNER VERIFICATION, AND AFTER LLD APPROVAL IS RECEIVED. CARE IS TO BE TAKEN <br />WHEN DISSEMBLING AND REMOVING BARRICADE, ON INTERIOR SIDE (STORE SIDE), PAPER WINDOWS WITH WHITE <br />CONSTRUCTION PAPER OVER GLAZING ONLY. TRIM 1/2" OFF EDGES AND TAPE CONTINUOUSLY AROUND PERIMETER <br />WITH WHITE TAPE. G.C. IS TO RESTORE NEUTRAL PIER(S), MALL FLOORING & BULKHEAD TO A LIKE NEW CONDITION <br />AND FINISH WHERE APPLICABLE. <br />Q. ALL EXISTING AND NEW PENETRATIONS THROUGH RATED WALLS SHALL BE PROTECTED BY AN APPROVED FIRE STOP <br />SYSTEM. SEE MALL OPERATIONS MANAGER. <br />R. G.C. TO REPORT ACTUAL DIMENSIONS VS SHOWN DIMENSIONS TO PROJECT MANAGER PRIOR TO CONSTRUCTION <br />LAYOUT. <br />1-PVC30-AD100-REV00 <br />il <br />• <br />MANAGEMENT <br />STORE 06261 <br />910 CENTER <br />910 SE EVERETT MALL WAY <br />EVE R ETT, WA 98208 <br />Construction for: <br />0 <br />Q ,t <br />0 <br />Do <br />O d�- <br />® <br />0 <br />O <br />14 <br />0 <br />a <br />v <br />O a <br />IW <br />�m <br />®' <br />o <br />�c) <br />o <br />Q oom <br />W <br />Revisions: <br />Mark Date <br />A <br />I <br />A <br />Architect of Record <br />C 0 R T L A N 0 <br />M N R G A N <br />ARCHITECT <br />711 N. FIELDER RD. <br />ARLINGTON, TX 76012 <br />PH: (817) 635-5696 <br />FAX: (817) 635-5699 <br />Seal <br />8897 <br />REGISTERED <br />A ITTECT <br />d <br />CORTLAND MORGAN <br />STATE Of WASHINGTON <br />Title <br />DEMOLITION PLAN <br />