CAT6 (QUANTITY AS <br />NEEDED), PLENUM <br />RATED CABLE. <br />THE EQUIPMENT IS ALL BY GC/EC. NOTE THE SPECIFIED PATCH <br />PANELS ARE MODULAR, SO THE PANDUIT CATS JACK IS REQUIRED <br />WITH THIS SYSTEM. THE JACK SNAPS INTO THE PATCH PANEL. <br />LABEL CABLE ^. <br />WITHIN 2 INCHES <br />OF TERMINATION. <br />4X4 BOX IN WALL WITH <br />SINGLE GANG ACTIVATION <br />FOR DATA OUTLET. <br />TERMINATE REQUIRED <br />NUMBER OF JACKS AND TEST <br />PLATE FINISH TO MATCH <br />ADJACENT RECEPTACLE <br />FINISH. <br />CONDUITS TO BE 3/4" UNLESS NOTED <br />OTHERWISE. WHERE REQUIRED BY CODE <br />OR LANDLORD, ALL LOW VOLTAGE <br />WIRING TO BE IN CONDUIT. <br />— x k�. <br />Eta <br />WHERE FREE AIR WIRING IS PERMITTED BY THE <br />LANDLORD AND LOCAL JURISDICTION, UTILIZE <br />J-HOOKS SPACED PER TIA/EIA STANDARDS. <br />WHERE CONDUIT IS REQUIRED, SIZE PER FILL <br />CHART. <br />ROUTE CONDUIT 6" ABOVE <br />WALL AND BUSH END. <br />SIZE CONDUIT PER FILL CHART. <br />LABEL CABLE WITHIN 2 INCHES OF <br />TERMINATION. <br />I , LABEL EACH OUTLET <br />MAXIMUM ALLOWABLE CONDUIT FILL (AUGMENTED CAT6) <br />3/4" C 2 DATA CABLES <br />TIC 4 DATA CABLES <br />1 1/4"C7 DATA CABLES <br />1 1/2"C10 DATA CABLES <br />2"C 18 DATA CABLES <br />122 <br />`-- MONITOR <br />1. EXTEND CABLE TO PROPOSED HEAD END EQUIPMENT <br />LOCATION. PROVIDE ENOUGH EXCESS CABLE TO REACH <br />ANY WALL IN BACK ROOM. COIL AND MARK CABLE AS <br />CCTV, HEAD END EQUIPMENT LOCATION MUST BE WITHIN <br />10' OF THE 'NETWORK SWITCH ACCESS'. <br />2. FOR CAMERAS, PROVIDE WHITE PLENUM RATED CAT 6 <br />CABLING. COIL 15' OF CABLING AT EACH CAMERA <br />LOCATION FOR CONNECTIONS. <br />3. PROVIDE RJ-45 CONNECTORS AT CAMERA LOCATIONS <br />ONLY. CONNECTORS NOT NEEDED AT THE HEAD END <br />EQUIPMENT LOCATION. <br />SECURITY CAMERAS SHALL NOT RECEIVE ANY ABOVE CEILING <br />JUNCTION BOX. THE CAMERAS HAVE THEIR OWN RECESS MOUNT KITS. <br />LOCATION OF CAMERAS SHALL BE MARKED CLEARLY IN ORDER FOR <br />SECURITY CAMERA TECHNICIAN TO LOCATE. ALL WIRING TO BE <br />PROVIDED AND INSTALLED PER ELECTRICAL PLANS. <br />CCTV SYSTEM RISER <br />CONNECT TO <br />NEAREST 120V, <br />CONVENIENCE <br />RECEPTACLE <br />CIRCUIT. N <br />120V TO 24V SYSTEM <br />TRANSFORMER IN <br />NEMA 1ENCLOSURE. <br />EDWARDS#592 <br />24V <br />SEC <br />NON —SALES <br />BUZZER (ABOVE <br />REAR DOOR) <br />EDWARDS <br />#340-4G5— <br />24VAC <br />PUSHBUTTON, <br />EDWARDS #852 <br />24V, SYSTEM <br />SALES BUZZER <br />AT CASH WRAP <br />EDWARDS <br />#340-4G5- <br />24VAC <br />SOUND SYSTEM RISER <br />O <br />Mark Date <br />A <br />Q <br />ineer of Record <br />Thorson o Baker <br />Associates <br />C O N S U L T I N G <br />E N G I N E E R S <br />3030 West Streetsboro Road <br />Richfield, Ohio 44286 <br />(330) 659-6688 Phone <br />(330) 659-6675 Fax <br />Seal <br />t4 � <br />FS <br />019 <br />Architect Job No.: <br />33N2022 <br />Nextore Store Design Revision No.: <br />Ali' i <br />NOTES, & SPECIFICATIONS <br />