Laserfiche WebLink
Panel Name: <br />Voltage: <br />120/208 <br />Panel Type: <br />PANELBOARD <br />Amps: <br />225 <br />Buss Amps <br />AIC <br />Rating: <br />MATCH EXISTING <br />MLO: <br />- <br />Main Lug Only <br />WATTS PER PHASE <br />WATTS PER PHASE <br />A B <br />C <br />DESCRIPTION OF LOAD <br />NOTES <br />OCPD <br />CKT# <br />CKT# <br />OCPD <br />NOTES <br />DESCRIPTION OF LOAD <br />A <br />B C <br />SPARE <br />20/1 <br />1 <br />2 <br />20/1 <br />SHELF LIGHTING (SWITCHED) <br />600 <br />720 <br />REC - PRETEST ROOM <br />20/1 <br />3 <br />4 <br />20/1 <br />SPARE <br />SPARE <br />20/1 <br />5 <br />6 <br />20/1 <br />LIGHT BOX (SWITCHED) <br />100 <br />1440 <br />REC EXAM ROOM <br />20/1 <br />7 1 <br />8 <br />20/1 <br />SPARE <br />1440 <br />REC-SMALL EXAM ROOM <br />20/1 <br />9 <br />10 <br />20/1 <br />ISPARE <br />SPARE <br />20/1 <br />11 <br />12 <br />20/1 <br />REC - PHONE BOARD <br />720 <br />360 <br />REC- BOH CONVENIENCE <br />20/1 <br />13 <br />14 <br />20/1 <br />REC - PHONE BOARD <br />540 <br />180 <br />REC - CONTACT LENS ROOM <br />20/1 <br />15 <br />16 <br />20/1 <br />ISPARE <br />360 <br />REC - ROOFTOP MAINTENANCE <br />20/1 <br />17 <br />18 <br />20/1 <br />ITIMECLOCK & CONTACTOR POWER <br />200 <br />360 <br />REC- WORK ROOM DESK <br />20/1 <br />19 <br />20 <br />20/1 <br />SPARE <br />3000 <br />WATER HEATER <br />40/2 <br />21 <br />22 <br />20/1 <br />REC - OD RECEPTION DESK <br />360 <br />3000 <br />23 <br />24 <br />20/1 <br />REC - OD RECEPTION DESK <br />360 <br />100 <br />RP-1 <br />20/1 <br />25 <br />26 <br />20/1 <br />REC OD RECEPTION DESK <br />360 <br />SPARE <br />20/1 <br />27 <br />28 <br />20/1 <br />CEF-1 <br />120 <br />SPARE <br />20/1 <br />29 <br />30 <br />2D/1 <br />GFI <br />REFRIGERATOR <br />1000 <br />2518 <br />31 <br />3'L <br />2dj1 <br />WATER DISPENSER <br />1000 <br />2518 <br />RTU-1 <br />30/3 <br />33 <br />34 <br />20/1 <br />ZiICROWAVE <br />1200 <br />2518 <br />35 <br />36 <br />20/1 <br />SPARE <br />5037 <br />37 <br />38 <br />6762 <br />Ii' <br />5037 <br />RTU-2 <br />50/3 <br />39 <br />40 <br />100/3 <br />PANELB <br />5923 <br />5037 <br />41 <br />42 <br />6670 <br />9815 <br />12895 <br />10915 <br />Totals <br />Totalsl 92621 <br />7603 <br />9050 <br />PANELCIRCUITNOTES: <br />Load Characteristics: <br />GFI =GROUND FAULT CIRCUIT INTERRUPTER <br />BREAKER <br />Total Load, Phase A: <br />19077 <br />Amps per Phase A: <br />159 <br />L= LOCK ON BREAKER <br />Total Load, Phase B: <br />20498 <br />Amps per Phase B: <br />171 <br />R = MARKED RED FOR FIRE ALARM <br />Total Load, Phase C: <br />19965 <br />Amps per Phase C: <br />166 <br />Total Panel Load: <br />59540 <br />Total Amps (assumes balanced): <br />165 <br />Panel Name: <br />D <br />Voltage: <br />120/208 <br />Panel Type: <br />PANELBOARD <br />Amps: <br />225 Buss Amps <br />AIC <br />Rating: <br />MATCH EXISTING <br />IVILO: <br />- Main Lug Only <br />WATTS PER PHASE <br />WATTS PER PHASE <br />A B <br />C <br />DESCRIPTION OF LOAD <br />INOTES <br />OCPD <br />CKT# <br />CKT# <br />OCPD <br />NOTES <br />DESCRIPTION OF LOAD <br />A <br />B C <br />Z82 <br />LTG - BOH EXAM AND COVES <br />L <br />20/1 <br />1 <br />2 <br />20/1 <br />LTG - STOREFRONT TRACK <br />360 <br />280 <br />LTG - BOH CORRIDOR, OFFICE, LOUNGE <br />L <br />20/1 <br />3 <br />4 <br />20/1 <br />LTG - SALES FLOOR TRACK <br />960 <br />250 LTG - SALES/OD RECEPETION <br />L <br />20/1 <br />5 <br />6 <br />20/1 <br />LTG - SALES FLOOR TRACK <br />480 <br />SPARE <br />20/1 <br />7 <br />8 <br />20/1 <br />LTG - SALES FLOOR TRACK <br />480 <br />SPARE <br />20/1 <br />9 <br />1 10 <br />20/1 <br />SPARE <br />6001 LTG - STOREFRONT SIGN (SWITCHED) <br />20/1 <br />11 <br />12 <br />20/1 <br />SPARE <br />SPARE <br />20/1 <br />13 <br />14 <br />20/1 <br />REC - SHOW WINDOW(SWITCHED) <br />720 <br />300 <br />LTG - SALES AREA SIGNS (SWITCHED) <br />20/1 <br />15 <br />16 <br />20/1 <br />REC - SALES DIGITAL DISPLAYS <br />360 <br />360REC -SALES PERIMETER -VISION OFFICE <br />20/1 <br />17 <br />18 <br />20/1 <br />REC - SALES FLOOR TABLES <br />360 <br />720 <br />REC- SALES PERIMETER (SWITCHED) <br />20/1 <br />19 <br />20 <br />20/1 <br />REC- SALES FLOOR TABLES <br />180 <br />1080 <br />REC - SALES PERIMETER (SWITCHED) <br />20/1 <br />21 <br />22 <br />20/1 <br />REC - SALES FLOOR FIXTURE (SWITCHED) <br />360 <br />1260 REC - SALES PERIMETER (SWITCHED) <br />20/1 <br />23 <br />24 <br />20/1 <br />SPARE <br />360 <br />REC- SALES PERIMETER (SWITCHED) <br />20/1 <br />25 <br />26 <br />20/1 <br />REC- CASH PHONE CABINET <br />360 <br />1080 <br />REC - SALES PERIMETER (SWITCHED) <br />20/1 <br />27 <br />28 <br />20/1 <br />REC - SALES CASH DESK <br />360 <br />1080 REC - SALES PERIMETER (SWITCHED) <br />20/1 <br />29 <br />30 <br />20/1 <br />REC - SALES CASH DESK <br />360 <br />1440 <br />REC - CUSTOM SALES PERIMETER (SWITCHED) <br />20/1 <br />31 <br />32 <br />20/1 <br />REC - SALES BACKWRAP <br />720 <br />SPARE <br />20/1 <br />33 <br />34 <br />20/1 <br />REC_- SALES BACKWRAP DIGITAL DISPLAY <br />540 <br />600 SALES FLOOR - LED WALL LW01 <br />20/1 <br />35 <br />36 <br />20/1 <br />REC - OD BACKWRAP <br />720 <br />600 <br />SALES FLOOR - LED WALL L`vV01 <br />20/1 <br />37 <br />38 <br />20/1 <br />REC - OD BACKWRAP DIGITAL DISPLAY <br />540 <br />600 <br />SALES FLOOR - LED WALL LW02 <br />20/1 <br />39 <br />40 <br />20/1 <br />SPARE <br />600 SALES FLOOR - LED WALL LW02 <br />20/1 <br />41 <br />42 <br />20/1 <br />SPARE <br />3402 3343 <br />4750 Totals <br />Totals <br />3360 <br />2580 1920 <br />PANEL CIRCUIT NOTES: <br />Load Characteristics: <br />GFI =GROUND FAULT CIRCUIT INTERRUPTER BREAKER <br />Total Load, Phase A: <br />6762 Amps per Phase A: <br />56 <br />L= LOCK ON BREAKER <br />Total Load, Phase B: <br />5923 Amps per Phase B: <br />49 <br />R = MARKED RED FOR FIRE ALARM <br />Total Load, Phase C: <br />6670 Amps per Phase C: <br />56 <br />Total Panel Load: <br />19355 Total Amps (assumes balanced): <br />54 <br />FIELD <br />VERIFY CONDITIONS <br />DESIGN DRAWINGS ARE SCHEMATIC. THE GENERAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO <br />BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL <br />INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING <br />CONDITIONS. <br />General Contractor's superintendent shall contact the LUXOTTICA RETAIL STORE MAINTENANCE <br />HOTLINE (513) 765-3500 upon arrival at the job site to schedule the transferal of temporary <br />utilities to the owner. Please provide the following information when calling: <br />1. Store Address and Space # <br />2. Temporary utility company(s) name and phone # (i.e., gas, electric, water, and <br />possibly sewer) <br />3. Meter or Socket # (if used), <br />4. Expected Punch Date. <br />Timing for new meter installations or utility account transfers will be executed on or before the <br />Punch Date. <br />ELECTRICAL <br />LOAD <br />SUMMARY <br />LOAD DESCRIPTION <br />CONNECTED LOAD <br />DEMAND <br />DEMAND LOAD <br />(KW) <br />FACTOR <br />(KW) <br />LIGHTING <br />3.1 <br />1m25 <br />3.9 <br />SHOW WINDOW RECEPTACLE <br />0.7 <br />1.0 <br />0.7 <br />SIGN <br />0,9 <br />1.25 <br />1.1 <br />RECEPTACLES <br />24.0 <br />100% 10K <br />50%>10K <br />17.0 <br />MISCELLANEOUS <br />3.9 <br />1.0 <br />3.9 <br />WATER HEATER <br />6.0 <br />1.25 <br />7.5 <br />HVAC <br />22.6 <br />1.25 OF LARGEST <br />MOTOR <br />23.9 <br />TOTAL (I(W) <br />61.2 <br />58.0 <br />TOTAL (AMPS) <br />170.1 <br />@120/208V, 3PH <br />161.2 <br />Revisions: <br />Mark Date <br />A <br />A <br />0 <br />0 Q -�T <br />DCD <br />O Ln <br />o <br />c <br />Num 0 <br />> 0 <br />C <br />X 0 <br />:D V) <br />J M <br />O <br />LU <br />vi X <br />99 15 —1 <br />uzv - - <br />Thorson - Baker <br />r- Associates <br />C O N S U L T I N G <br />E N G I N E E R S <br />3030 West Streetsboro Road <br />Richfield, Ohio 44286 <br />(330)659-6688 Phone <br />(330) 659-6675 Fax <br />Architect Job No.: <br />33N2022 <br />Nextore Store Design Revision No.: <br />fr <br />Nextore Project <br />Number 86841 <br />Brand Design Type: <br />Si <br />ISSUED FOR: <br />® CONSTRUCTION <br />Title <br />IFS, & SPECIFICATIONS <br />®ate 04/19/2022 <br />Drawn By <br />T B_A _ <br />Checked By <br />TBA <br />Sheet <br />