Laserfiche WebLink
q <br />eu <br />� x� ,�. � � ��, �� •. ram: s.. �. � s �.. ;��,., �u �a� � s <br />ur <br />t <br />*.: �,� ,��' � ',,•; ,',-F`,e � n,�'. x;;• :'ma's.. .. z -,-.:: '.,x%� � t� �,; x" ., <br />m . .��, � �"��:•� �"�� � - ��: ;� �_- • . - _�e���_ �';�' fir" �fik � ,�,�� �.. <br />G0.01 <br />COVER SHEET <br />G1.00 <br />SITE PLAN <br />G1.01 <br />PLAY AREA CONCEPT PLANS AND INFO - - <br />G2.01 <br />CODE AND AREA ANALYSIS - - <br />AD2.01 <br />DEMO FIRST FLOOR PLAN - <br />_AD2.21 <br />DEMO RCP <br />A2.01 <br />FIRST FLOOR PLAN - <br />A6.01 <br />ENLARGED TOILET PLANS AND ELEVATIONS -- <br />A8.01 <br />REFLECTED CEILING PLAN <br />A9.01 <br />DOOR AND WALL TYPES, SCHEDULE AND DETAILS - <br />A10.01 <br />FINISH FLOOR PLANS - - <br />M0.00 <br />HVAC LEGEND, ABBREVIATIONS, AND GENERAL NOTES -- <br />MD2.01 <br />FIRST FLOOR HVAC DEMOLITION PLAN <br />M2.01 <br />FIRST FLOOR HVAC PLAN <br />M5.01 <br />HVAC DETAILS <br />M6.01 <br />HVAC SCHEDULES <br />P0.00 <br />_ <br />PLUMBING LEGEND, ABBREV. & GENERAL NOTES <br />P2.00 <br />BASEMENT_ PLUMBING PLAN <br />P2.01 <br />FIRST FLOOR PLUMBING PLAN <br />P4.01 <br />PLUMBING ENLARGED PLANS <br />P6.01 <br />PLUMBING SCHEDULES <br />FP0.00 <br />FIRE PROTECTION LEGEND, ABBREV. & GENERAL NOTES <br />FP2.01 <br />FIRST FLOOR FIRE PROTECTION PLAN <br />E0.01 <br />ELECTRICAL LEGEND AND DRAWING INDEX <br />E0.02 <br />ELECTRICAL GENERAL NOTES AND ABBREVIATIONS <br />E0.03 <br />ELECTRICAL AND SECURITY SCHEDULES <br />ED2.01 <br />LIGHTING DEMOLITION FLOOR PLAN -- <br />ED3.01 <br />POWER DEMOLITION FLOOR PLAN <br />ED6.01 <br />LOW_ -VOLTAGE & FIRE ALARM DEMOLITION FLOOR PLAN <br />E2.01 <br />LIGHTING FLOOR PLAN - <br />E2.01A <br />LIGHTING CONTROL ZONE FLOOR PLAN <br />E3.01 <br />POWER FLOOR PLAN <br />E6.01 <br />LOW -VOLTAGE & FIRE ALARM FLOOR PLAN <br />E6.02 <br />TELECOM & SECURITY PLAN & ELEVATIONS <br />E7.01 <br />ELECTRICAL DETAILS <br />E8.01 <br />LOW -VOLTAGE DETAILS <br />E9.01 <br />ELECTRICAL ONE -LINE DIAGRAM_ <br />E10.01 <br />PANEL SCHEDULES <br />FS1.1 <br />FOOD SERVICE FLOOR PLAN AND SCHEDULE <br />FS2.1 <br />FOOD SERVICE PLUMBING REQUIREMENT PLAN <br />FS3.1 <br />FOOD SERVICE ELECTRICAL REQUIREMENT PLAN -- <br />FS4.1 <br />FOOD SERVICE SPECIAL CONDITION REQUIREMENT PLAN <br />FS5.1 <br />ELEVATIONS AND DETAILS -- <br />IN <br />MINI], 11-1-1, a ij, -0 <br />1. VERIFY AND COORDINATE SITE CONDITIONS, EXISTING BUILDING CONDITIONS, AND DIMENSIONS. <br />BRING INCONSISTENCIES TO ATTENTION OF ARCHITECT BEFORE: PROCEEDING WITH WORK. <br />2. IMMEDIATELY BRING INCONSISTENCIES, ERRORS AND OMISSIONS FOUND IN THE DRAWINGS AND <br />SPECIFICATIONS TO ATTENTION OF ARCHITECT. <br />3. DO NOT SCALE DRAWINGS. COORDINATE DIMENSIONS SHOWN ON DRAWINGS WITH ACTUAL FIELD <br />MEASUREMENTS. NOTIFY ARCHITECT OF DISCREPANCIES. <br />4. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CONCRETE AND NOMINAL FACE OF MASONRY, AND <br />CENTERLINE OF COLUMNS, UNLESS NOTED OTHERWISE. <br />5. WORK INSTALLED IN CONFLICT WITH CONSTRUCTION DOCUMENTS WILL BE CONSIDERED IN NOW <br />CONFORMANCE AND SHALL BE CORRECTED AT NO EXPENSE TO OWNER OR ARCHITECT. <br />6. COORDINATION: COORDINATE WORK TO COMPLY WITH DRAWINGS AND SPECIFICATIONS, INCLUDING <br />MECHANICAL, ELECTRICAL, EQUIPMENT AND OTHER CONSTRUCTION. <br />7. FOLLOW MANUFACTURER'S INSTRUCTIONS, EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE <br />INDICATED OR REQUIRED BY CONSTRUCTION DOCUMENTS OR APPLICABLE CODES, ORDINANCES <br />AND REGULATIONS. <br />8. ISOLATE. AND OFFSET OUTLETS ONE STUD SPACE MINIMUM AT SOUND RATED WALLS TO PREVENT <br />SOUND TRANSMISSION. <br />9. COORDINATE EXACT LOCATION OF CONDUIT, PLUMBING AND PIPING WITH ELECTRICAL AND <br />MECHANICAL SUBCONTRACTORS. <br />10. FINISHES: IN FINISHED INTERIOR AREAS: NO EXPOSED PIPE, CONDUITS, DUCTS, VENTS, ETC, <br />UNLESS NOTED OTHERWISE, CONCEAL UTILITY LINES BEHIND FINISHED CONSTRUCTION UNLESS <br />NOTED AS EXPOSED CONSTRUCTION ON DRAWINGS OR APPROVED BY ARCHITECT. IF <br />AFOREMENTIONED WORK CANNOT BE CONCEALED WITHIN FINISHED CONSTRUCTION OF THE <br />CONTRACT DOCUMENTS THE CONTRACTOR SHALL PROVIDE & INSTALL FURRED & FINISHED <br />HORIZONTAL & VERTICAL CHASES TO MATCH ADJACENT FINISH TO CONCEAL WORK, COORDINATE <br />WITH ARCHITECT. <br />11. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. <br />12. CORNER GUARDS ARE SHOWN ON FINISH PLANS, A-10 SERIES. <br />ACP <br />ACOUSTICAL CEILING PANEL <br />MAX <br />MAXIMUM <br />ACT <br />ACOUSTICAL CEILING TILE <br />MDF <br />MEDIUM DENSITY FIBERBOARD <br />AFF <br />ABOVE FINISH FLOOR <br />MDO <br />MEDIUM DENSITY OVERLAY <br />ALUM <br />ALUMINUM <br />MFR <br />MANUFACTURER <br />APPROX <br />APPROXIMATE <br />MISC <br />MISCELLANEOUS <br />AVE <br />AVENUE <br />MO <br />MASONRY OPENING <br />AVG <br />AVERAGE <br />MET <br />METAL <br />BLDG <br />BUILDING <br />NA <br />NOT APPLICABLE <br />BOT <br />BOTTOM <br />NIC <br />NOT IN CONTRACT <br />C <br />AMERICAN STANDARD CHANNEL <br />NR <br />NON RATED <br />CF/CI <br />CONTRACTOR FURNISHED / CONTRACTOR INSTALLED <br />NTS <br />NOT TO SCALE <br />CF/OI <br />CONTRACTOR FURNISHED / OWNER INSTALLED <br />OC <br />ON CENTER <br />CPT <br />CARPET <br />OD <br />OUTSIDE DIAMETER <br />CG <br />CORNER GUARD <br />OFCI <br />OWNER FURNISHED; CONTRACTOR INSTALLED <br />CJ <br />CONTROL JOINT <br />OFOI <br />OWNER FURNISHED; OWNER INSTALLED <br />CL <br />CENTER LINE <br />OPNG <br />OPENING <br />CMU <br />CONCRETE MASONRY UNIT <br />OPP <br />OPPOSITE <br />COL <br />COLUMN <br />OZ <br />OUNCE <br />CONC <br />CONCRETE <br />P <br />PAINT <br />CT <br />CERAMIC TILE <br />PERP <br />PERPENDICULAR <br />DEPT <br />DEPARTMENT <br />PL <br />PLATE <br />DF <br />DRINKING FOUNTAIN <br />PLAM <br />PLASTIC LAMINATE <br />DIA <br />DIAMETER <br />PLYWD <br />PLYWOOD <br />DIM <br />DIMENSION <br />PNL <br />PANEL <br />DIM PT <br />DIMENSION POINT <br />PSF <br />POUNDS PER SQUARE FOOT <br />DN <br />DOWN <br />PSI <br />POUNDS PER SQUARE INCH <br />DR <br />DOOR <br />RCP <br />REFLECTED CEILING PLAN <br />DW <br />DISHWASHER <br />REBAR <br />REINFORCING BAR <br />DWG <br />DRAWING <br />RM <br />ROOM <br />EA <br />EACH <br />RO <br />ROUGH OPENING <br />EL <br />ELEVATION <br />ROW <br />RIGHT OF WAY <br />ELEC <br />ELEC <br />SCHD <br />SCHEDULE <br />ELEV <br />ELEVATOR <br />SF <br />SQUARE FEET <br />EQUIP <br />EQUIPMENT <br />SHTG <br />SHEATHING <br />EXIST <br />EXISTING <br />Sim <br />SIMILAR <br />EXT <br />EXTERIOR <br />SPEC <br />SPECIFICATIONS <br />FA <br />FIRE ALARM <br />SST <br />STAINLESS STEEL <br />FD <br />FLOOR DRAIN <br />STC <br />SOUND TRANSMISSION CLASS <br />FE <br />FIRE EXTINGUISHER <br />STD <br />STANDARD <br />FEC <br />FIRE EXTINGUISHER CABINET <br />SUSP <br />SUSPENDED <br />FOF <br />FACE OF FINISH <br />T&G <br />TONGUE AND GROOVE <br />FOM <br />FACE OF MASONRY <br />TOG <br />TOP OF CURB / TOP OF CONCRETE <br />FOS <br />FACE OF STUDS <br />TYP <br />TYPICAL <br />FTG <br />FOOTING <br />UL <br />UNDERWRITERS LABORATORIES <br />GA <br />GAUGE <br />UNO <br />UNLESS NOTED OTHERWISE <br />GC <br />GENERAL CONTRACTOR <br />VERT <br />VERTICAL <br />GWB <br />GYPSUM WALL BOARD <br />VOL <br />VOLUME <br />GYP <br />GYPSUM <br />W/O <br />WITHOUT <br />HDWD <br />HARDWOOD <br />WD <br />WOOD <br />HM <br />HOLLOW METAL <br />WDW <br />WINDOW <br />HORN <br />HORIZONTAL <br />WT <br />WEIGHT <br />ID <br />INSIDE DIAMETER <br />IN <br />INCHES <br />INT <br />INTERIOR <br />JT <br />JOINT <br />L <br />LENGTH /ANGLE: (AS STRUCTURAL SHAPE) <br />LB <br />POUND <br />LF <br />LINEAR FOOT <br />J, tl x T W� <br />BUILDING ELEVATION <br />1 ELEVATION ID <br />A3.10 <br />SHEET NUMBER <br />SECTION ID <br />a _ <br />A3.21 <br />SHEET NUMBER <br />1 SECTION ID <br />A4.11 - <br />SHEET NUMBER <br />DETAIL REFERENCE <br />DETAIL ID <br />1 <br />A 9.04 <br />SHEET NUMBER <br />=A <br />NIX <br />GRID LINES <br />1*1 <br />MATCH LINE <br />r� „X - <br />A2.12 LOCATION OF ADJACENT <br />DRAWING <br />t <br />93 1%PPROVED WFTH CINAPMES NOTIED <br />K3 REWSE AND 6T <br />10 REJECTED. <br />SEE ATTACHED CHECKLIST/HANDOUT <br />I he Issuance of a permit shall not <br />be construed as authority to violate, <br />cancel or set aside any provision of <br />the Everett Fire Code or other <br />applicable regulations or laws. The <br />15SUORce of a permit base o <br />construction docu elits and other <br />d to 0811 fl t PrMnt the Five Cede <br />OffIoal from requiring the correction <br />of errors. <br />Permit#: <br />PW2205-024 <br />Site Address: <br />3201 SMITH AVE <br />Owner: <br />CITY OF EVEREiT <br />Tenant: <br />BEZOS ACADEMY, EVERETT TRANSIT <br />STATION <br />App.Date: <br />5/26/2022 <br />Proposed Use: <br />Description: <br />SITE WORK FOR BEZOS ACADEMY <br />Reviewed By:__ & Date e <br />Offiice Set Jcb Site Set Fire/Planning Set <br />THESE DOCUMENTS HAVE NOT' BEEN <br />APPROVED 17OR THE 1SSUANCE OF <br />PUBLIC WORK, MECHANICAL, FIRE <br />SUPPRESSION, FLLI C`fRICAL OR <br />PLUMBING PERMITS <br />1�= a1 <br />Addiflon l Permits Are Required <br />For This Project TO Include: <br />PlumbingSprinkle,l <br />Mechanical Fire Alarm <br />Electrical <br />1t L - LOUVER <br />S-STOREFRONT <br />R - INTERIOR BORROWED LITE <br />P2 RESTORATION KEYNOTE <br />DOOR NUMBER <br />1t <br />C,'-0" CEILING INDICATOR <br />► • FLOOR INDICATOR <br />i SIGNAGE INDICATOR <br />MODEL <br />102 CASEWORK INDICATOR <br />30 24 <br />WIDTH 34.5� DEPTH <br />HEIGHT <br />t <br />PARTITION <br />AFLOOR BOX <br />EXIT SIGN <br />X METAL SHELVING <br />APPROVED <br />ff <br />Joeof Ofnlintanily, Planning &Ern®nrie DevelOP11 <br />PLANNING DRPAR i MENT <br />�( DATE: <br />NAME:B_ <br />Permit#: B2205-053 <br />Site Address: 3201 SMITH AVE <br />Owner: CITY OF EVEREIT <br />Tenant: BEZOS ACADEMY, EVEREITTRANSrr <br />STATION <br />App.Date: 5/17/2022 <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Description: TI: (3) CLASSROOM PRESCHOOL ON 1S1 <br />FLOOR OF TRANSIT BLDG <br />Reviewed By: ��G Date. =7 <br />\ Office Set Job Site Set Fire/Planning Set <br />Seattle, Washington 01 <br />9500 <br />o <br />MEClANICA L ENGINEER <br />FSi <br />1001 Alaskan Way, Suite 200 <br />Seattle WA 98104 <br />T (206) 385 6124 <br />ELECTRICAL ENGINEER <br />Hargis <br />1201 Third Avenue, Suite 600 <br />Seattle WA 98101 <br />T (206) 436 0457 <br />Seattle,. 98109 <br />625 0070 <br />ONE INCH <br />NESEM <br />AT FULL SIZE <br />This document has been digitally signed <br />542� <br />FARCR1T'8CT <br />1 d ; t 1, <br />VM- <br />DANIEL MILES <br />STATE Or WASHTNGTON <br />05/12/2022 3:04:21 <br />PM <br />0 REVISIONS DATE <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />JOB NO: 2018 <br />ISSUE DATE: 05/12/22 <br />1 • � <br />:_ _' R , x. <br />