Laserfiche WebLink
RCP LEGEND <br />311 = 11-011 <br />8" MAX <br />12 GA. VERTICAL WIRE AND <br />HORIZONTAL RESTRAINT — <br />8" MAX <br />V <br />\ <br />" :::T: <br />1/8" POP --- <br />RIVET @ ALL <br />CEILING FINISH; SEE RCP - <br />MEMBERS <br />PROVIDE 3/4" <br />ONE WALL <br />MAIN RUNNER OR CROSS TEE <br />GRID <br />2" WIDE SHADOW MOLDING <br />END WALL <br />CLEARANCE <br />12 GA. HANGER WIRE @ <br />COMPRESSION STRUT <br />4'-0" <br />WITHIN 2" OF <br />O.C. IN BOTH DIRECTIONS <br />INTERSECTION AND <br />ALL <br />SPLAYED 90' APART AT 45° <br />HANGERS AND SPLAY <br />ANGLES <br />\ <br />WIRES TO HAVE A MIN. OF 3 <br />19 \ <br />TURNS IN 1" OF RUN <br />SPLAYWIRE <br />j!!:: <br />BRACING <br />O.C. STARTING 6' <br />FROM WALLS <br />_ <br />MAIN RUNNER <br />45' TYPICAL <br />45' TYPICAL <br />CROSS TEE <br />— HORIZONTAL RESTRAINT BRACING: 12 GA. WIRE HANGERS <br />A @ 4'-0" O.C. EACH WAY (SEE NOTE BELOW) <br />o <br />o� <br />90.00° <br />COMPRESSION STRUT <br />SEE TABLE BELOW <br />C <br />EA ASTM C635 & ASTM C636 COMPLIANT N HEAVY T - DUTY <br />BAR SUSPENDED GRID CEILING: MAIN RUNNERS @ <br />4'-0" O.C. CROSS TEE AND SUB -TEE @ 2-0" O.C., TYP. <br />NOTE: LATERAL FORCE BRACING MEMBERS SHALL BE SPACED A <br />MINIMUM OF 6 INCHES FROM ALL HORIZONTAL PIPING OR <br />DUCTWORK THAT IS NOT PROVIDED WITH BRACING <br />RESTRAINTS FOR HORIZONTAL FORCES. BRACING WIRES <br />SHALL BE ATTACHED TO THE GRID AND TO THE <br />STRUCTURE IN SUCH A MANNER THAT THEY CAN SUPPORT <br />A DESIGN LOAD OF NOT LESS THAN 200 LBS. OR THE <br />ACTUAL LOAD, WHICH EVER IS GREATER, WITH A SAFETY <br />FACTOR OF 2. <br />SEE SPECIFICATION 095115 FOR METAL SUSPENSION <br />SYSTEM REQUIREMENTS, TYP. <br />COMPRESSION STRUT TABLE <br />METAL STUD — <br />SHEET MTL. SCREW <br />A <br />B <br />LENGTH OF STRUT <br />TYPE <br />DESCRIPTION <br />0" TO 8'-0" <br />A <br />1 - 3 5/8" x 25 GA. MTL. STUD <br />8'-1" TO 10'-0" <br />B <br />2 - 1 5/8" x 25 GA. MTL STUDS <br />W/ <br />SHEET MTL. SCREWS (a)- 12" <br />10'-1" TO 15'-0" <br />B <br />2 -C2 1/2" x 25 GA. MTL. STUDS <br />W/ <br />SHEET MTL. SCREWS (a)- 12" <br />15'-1" TO 20'-0" <br />B <br />2 -C3 1/2" x 25 GA. MTL STUDS <br />W/ <br />SHEET MTL. SCREWS @ 12" <br />O.C. <br />SUSPENDED CEILING DETAILS, TYP. <br />1211 = 11-011 <br />CEILING <br />ACP-1 095113 24"X24" SCRUBBABLE CEILING <br />PANELS <br />ACP-2 095113 24"X48" LAY -IN CEILING TILES <br />GWB 092900 GYP BOARD CEILING <br />F-1 EXTENT NOT IN SCOPE OF INTERIOR <br />L -1 RENOVATION. <br />PATCH AND REF <br />MATCH EXIST <br />PAINT P-3. <br />OPENING IN SO <br />TO ALLOW Hi <br />VENT DUCT W <br />TO GO THROUGI <br />LOU <br />i R �, <br />Sao..-. <br />(E) SOFFIT AND <br />CEILING PAINT <br />1IM11:49 <br />FOR COMPLETE FIXTURE INFORMATION, INCLUDING MOUNTING, <br />HEIGHT, TYPE AND LAMPING, REFER TO ELECTRICAL AND MECHANICAL <br />DRAWINGS <br />E PENDANT MOUNTED FIXTURE EXIT SIGNAGE, REFER TO ELECTRICAL DRAWINGS <br />DIV 23 SUPPLY DIFFUSER. REFER TO <br />MECHANICAL DRAWINGS <br />48 x 24 RECESS MOUNTED FIXTURE El DIV 23 RETURN. REFER TO MECHANICAL DRAWINGS <br />24 x 24 RECESS MOUNTED FIXTURE <br />48 x 3 SURFACE MOUNTED FIXTURE <br />REFLECTED CEILING PLAN <br />1 /8" = 11-011 <br />1. REPLACE ALL ELECTRICAL FIXTURES WITH LED <br />FIXTURES> MODIFY LIGHT SWITCH LOCATIONS AS <br />NEEDED. <br />2. MODIFY EXISTING SPRINKLER COVERAGE AS NEEDED. <br />REFER TO MECHANICAL FOR MORE INFORMATION. <br />0' 2' 4' 8' <br />EA <br />�I <br />bassetti <br />archite <br />cts <br />71 Columbia Street, Suite 500 <br />Seattle, Washington 98104 <br />T (206) 340 9500 <br />www.basseftiarch.com <br />MECHANICAL ENGINEER <br />FSi <br />1001 Alaskan Way, Suite 200 <br />Seattle WA 98104 <br />T (206) 385 6124 <br />ELECTRICAL ENGINEER <br />Hargis <br />1201 Third Avenue, Suite 600 <br />Seattle WA 98101 <br />T (206) 436 0457 <br />FOOD SERVICE <br />JLR Design Group <br />557 Roy St. Suite 175-A <br />Seattle, WA 98109 <br />T (206) 625 0070 <br />ONE <br />AT FULL SIZE <br />This document has been digitally signed <br />5428 <br />RSt;1:STERED <br />ARCHITECT <br />DANIEL MILES <br />STATE O WASHING TON <br />05/12/2022 3:04:32 <br />PM <br />REVISIONS DATE <br />Owner <br />BEZOS ACADEMY - <br />EVERETT TRANSIT <br />STATION <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />JOB NO: 2018 <br />ISSUE DATE: 05/12/22 <br />Jurisdiction Stamp Area <br />REFLECTED <br />CEILING PLAN <br />