ROOM FINISH SCHEDULE <br />ROOM FLOOR WALLS CASEWORK <br />NUMBER ROOM NAME FINISH TBASE NORTH EAST SOUTH WEST CEILING VERT HORIZ REMARKS <br />100 <br />VESTIBULE <br />EM-1 <br />RB-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />ACP-2 <br />100A <br />CORRIDOR <br />CP17-1 <br />RB-1 <br />P-1 <br />P-1 <br />P-1 <br />FPR-1, P-1 <br />ACP-2 <br />PLAM-2 <br />REFERENCE FINISH PLAN & ELEVATIONS <br />FOR FRP EXTENTS <br />100B <br />ADULT TLT <br />RSF-1 <br />IB <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FPR-1, P-1 <br />ACPA <br />PLAM-2 <br />PLAM-1 <br />100C <br />Room <br />101 <br />CLASSROOM 1 <br />RPT-1 <br />RB-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />ACP-2 <br />PLAM-2 <br />PLAM-1 <br />REFERENCE FINISH PLAN & ELEVATIONS <br />FOR FRP EXTENTS <br />101A <br />STO. <br />RPT-1 <br />RB-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />GWB, P-3 <br />101 C <br />CLO. <br />CPTT-1 <br />- <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />GWB, P-3 <br />102 <br />CLASSROOM 2 <br />RPT-1 <br />RB-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />ACP-2 <br />PLAM-2 <br />PLAM-1 <br />REFERENCE FINISH PLAN & ELEVATIONS <br />FOR FRP EXTENTS <br />102A <br />CHILDREN'S TLT <br />RSF-1 <br />IB <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FPR-1, P-1 <br />ACP-1 <br />PLAM-2 <br />PLAM-1 <br />103 <br />CLASSROOM 3 <br />RPT-1 <br />RB-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />ACP-2 <br />PLAM-2 <br />PLAM-1 <br />REFERENCE FINISH PLAN & ELEVATIONS <br />FOR FRP EXTENTS <br />103A <br />CHILDREN'S TLT <br />RSF-1 <br />IB <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FPR-1, P-1 <br />ACPA <br />PLAM-2 <br />PLAM-1 <br />104 <br />HOS <br />CPTT-1 <br />RB-1 <br />P-1 <br />P-1 <br />P-1 <br />P-1 <br />ACP-2 <br />105 <br />WARMING KITCHEN <br />RSF-1 <br />IB <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FPR-1, P-1 <br />ACPA <br />FRP TO 5'-0" AFF <br />106 <br />STAFF LOUNGE <br />CPTT-1 <br />RB-1 <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FRP-1, P-1 <br />FPR-1, P-1 <br />ACP-2 <br />107 <br />CUST. <br />RSF-1 <br />IB <br />P-1 <br />FRP-1, P-1 <br />FRP-1, P-1 <br />P-1 <br />GWB, P-3 <br />REFERENCE FINISH PLAN & ELEVATIONS <br />FOR FRP EXTENTS <br />WALL PER <br />PLAN <br />(066400) REINFORCED <br />FIBER PANEL (FRP-1), <br />AS OCCURS <br />(096500) 4" RESILIENT <br />WALL BASE, (RB-1) <br />(096800) CARPET <br />TILE, (CPTT-1) OR <br />ENTRANCE CARPET <br />MAT (EM-1) <br />CARPET (CPTT-1/EM-1) W/ <br />RESILIENT WALL BASE <br />WALL PER <br />PLAN <br />(096500) 4" RESILIENT <br />WALL BASE, (RB-1) <br />(096500) RESILIENT <br />PLANK TILE (RPT-1) <br />RESILIENT PLANK TILE (RPT-1) <br />W/ RESILIENT WALL BASE <br />TYPICAL WALL BASE <br />3" = 1'-01, <br />V I DOOR PANEL <br />(WHERE OCCURS) <br />I <br />(096500) RESILIENT <br />TRIM <br />(096800) CARPET I (096500) RESILIENT <br />TILE (CPTT-1) FLOORING (RPT-1, <br />77, RSF-1) <br />TT-1, TRANSITION CENTER TRANSITION <br />TYPE 1 BENEATH DOOR PANEL, TYP <br />DOOR PANEL <br />(WHERE OCCURS) <br />(096500) <br />(096800) CARPET RESILIENT TRIM <br />TILE (CPTT-1) I (096800) ENTRANCE <br />N CARPET (EM-1) <br />TT-2, TRANSITION �- <br />TYPE 2 CENTER TRANSITION <br />BENEATH DOOR PANEL, TYP <br />v DOOR PANEL <br />(WHERE OCCURS) <br />I <br />(096500) RESILIENT <br />x <br />T-MOLDING <br />(096500) RESILIENT Lj <br />I (096500) RESILIENT <br />FLOORING (RPT-1) <= FLOORING (RSF-1) <br />as a <br />TT-3, TRANSITION CENTER TRANSITION <br />TYPE 3 BENEATH DOOR PANEL, TYP <br />(096500) RESILIENT <br />TRANSITION JOINER <br />a <br />(096500) RESILIENT EXISTING TERRAZZO <br />FLOORING (RPT-1) .= <br />- a - - .° - a - � •.nix - - - m� _, d ....> -..-.. <br />TT-3, TRANSITION <br />TYPE 4 <br />FLOOR FINISH TRANSITION DETAIL <br />6" = 1'-0" <br />WALL PER <br />PLAN <br />II�1►r1 <br />!600) CORNER <br />kRD, <br />TALLED PER <br />2 <br />WALL PER <br />PLAN <br />(066400) REINFORCED <br />I FIBER PANEL (FRP-1), <br />AS OCCURS <br />METAL TRIM <br />r(096500) 4" INTEGRAL <br />COVE BASE <br />(096500) RESILIENT SHEET <br />l- FLOORING (RSF-1) <br />RESILIENT SHEET FLOORING <br />(RSF-1) W/ INTEGRAL WALL BASE <br />(102600) CORNER <br />GUARD <br />RESILIENT WALL <br />BASE, PER <br />SCHEDULE <br />FINISHED FLOOR, <br />PER PLAN <br />SECTION ELEVATION <br />3" = 1'-0" <br />RESILIENT <br />OUTSIDE CORNER <br />TRIM, TO MATCH <br />PANEL <br />FRP-1 <br />PLAN VIEW AT <br />OUTSIDE CORNER <br />WALL PER <br />PLAN, TYP. <br />SEALANT <br />RESILIENT EDGE TRIM, <br />TO MATCH PANEL <br />SEALANT <br />FRP-1 <br />HORIZONTALIVERTICAL EDGES <br />FRP-1 (AS <br />OCCURS) <br />SEALANT <br />CORNER <br />GUARD <br />SEALANT <br />FRP-1 <br />PLAN VIEW AT OUTSIDE <br />CORNER W/ CORNER GUARD <br />RESILIENT INSIDE <br />CORNER TRIM, TO <br />MATCH PANEL <br />FRP-1 <br />PLAN VIEW AT INSIDE CORNER <br />TYPICAL FRP DETAIL <br />3" 1'-0" <br />F. "v ,.+' <br />I <br />, <br />�.� <br />1/8" = 1'-0" <br />CPTT-1 CARPET TILE (096800) <br />EM-1 ENTRANCE CARPET MAT (096800) <br />-- -- ------ RPT-1 RESILIENT PLANK TILE (096500) <br />---- ----- --- (DIRECTION INDICATED W/ SYMBOL) <br />RSF-1 RESILIENT SHEET FLOORING (096500) <br />1. HOLLOW METAL DOOR FRAMES AND WOODEN DOOR <br />FRAMES TO BE PAINTED P-2. <br />2. WINDOW SILLS AND WINDOW FRAMES TO BE PAINTED P-2. <br />3. TILE TO BE INSTALLED CENTERED ON ROOM TYP, UNO. <br />4. WALLS TO BE PAINTED P-1 TYP, UNO. <br />FINISH PLAN ABBREVIATION <br />EXISTING FLOORING TO REMAIN <br />laa <br />ACP <br />ACOUSTICAL CEILING PANEL <br />IB <br />AFF <br />ABOVE FINISH FLOOR <br />OFCI <br />F - <br />CL <br />CENTER LINE <br />CONC <br />CONCRETE <br />OFOI <br />I I <br />NOT IN SCOPE <br />CPTT <br />CARPET TILE <br />L - <br />(E) <br />EXIST / EXISTING <br />P <br />EM <br />ENTRANCE CARPET MAT <br />PLAM <br />ES <br />EXPOSED TO STRUCTURE <br />RB <br />- - - - - - - - - - - <br />FRP-1 FIBER REINFORCED PANEL (066400) <br />FOF <br />FACE OF FINISH <br />RPT <br />FRP <br />FIBER REINFORCED PANEL <br />RSF <br />GWB <br />GYPSUM WALL BOARD <br />SS <br />CG-# <br />CORNER GUARD <br />GYP <br />GYPSUM <br />TT <br />HM <br />HOLLOW METAL <br />VIF <br />TT-# <br />TRANSITION TYPE <br />FLOOR PATTERN DIRECTION SYMBOL <br />INTEGRAL BASE (COVE) <br />OWNER FURNISHED, <br />CONTRACTOR INSTALLED <br />OWNER FURNISHED, OWNER <br />INSTALLED <br />PAINT <br />PLASTIC LAMINATE <br />RESILIENT BASE <br />RESILIENT PLANK TILES <br />RESILIENT SHEET FLOORING <br />STAINLESS STEEL <br />TRANSITION TYPE <br />VERIFY IN FIELD <br />bassetti <br />architects <br />71 Columbia Street, Suite 500 <br />Seattle, Washington 98104 <br />T (206) 340 9500 <br />www.bassettiarch.com <br />MECHANICAL ENGINEER <br />FSi <br />1001 Alaskan Way, Suite 200 <br />Seattle WA 98104 <br />T (206) 385 6124 <br />ELECTRICAL ENGINEER <br />Hargis <br />1201 Third Avenue, Suite 600 <br />Seattle WA 98101 <br />T (206) 436 0457 <br />FOOD SERVICE <br />JLR Design Group <br />557 Roy St. Suite 175-A <br />Seattle, WA 98109 <br />T (206) 625 0070 <br />ONE INCH <br />AT FULL SIZE <br />This document has been digitally signed <br />5428 <br />F <br />ST"R': � <br />ARCji <br />ITECT <br />QA"4 1, V <br />DANIEL MILES <br />s TL o>{ wz�sxIr t ora <br />05/12/2022 3:04:33 <br />PM <br />REVISIONS DATE <br />Owner <br />BEZOS ACADEMY - <br />EVERETT TRANSIT <br />STATION <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />JOB NO: 2018 <br />ISSUE DATE: 05/12/22 <br />Jurisdiction Stamp Area <br />FINISH FLOOR <br />PLANS <br />