ROOM FINISH SCHEDULE
<br />ROOM FLOOR WALLS CASEWORK
<br />NUMBER ROOM NAME FINISH TBASE NORTH EAST SOUTH WEST CEILING VERT HORIZ REMARKS
<br />100
<br />VESTIBULE
<br />EM-1
<br />RB-1
<br />P-1
<br />P-1
<br />P-1
<br />P-1
<br />ACP-2
<br />100A
<br />CORRIDOR
<br />CP17-1
<br />RB-1
<br />P-1
<br />P-1
<br />P-1
<br />FPR-1, P-1
<br />ACP-2
<br />PLAM-2
<br />REFERENCE FINISH PLAN & ELEVATIONS
<br />FOR FRP EXTENTS
<br />100B
<br />ADULT TLT
<br />RSF-1
<br />IB
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FPR-1, P-1
<br />ACPA
<br />PLAM-2
<br />PLAM-1
<br />100C
<br />Room
<br />101
<br />CLASSROOM 1
<br />RPT-1
<br />RB-1
<br />P-1
<br />P-1
<br />P-1
<br />P-1
<br />ACP-2
<br />PLAM-2
<br />PLAM-1
<br />REFERENCE FINISH PLAN & ELEVATIONS
<br />FOR FRP EXTENTS
<br />101A
<br />STO.
<br />RPT-1
<br />RB-1
<br />P-1
<br />P-1
<br />P-1
<br />P-1
<br />GWB, P-3
<br />101 C
<br />CLO.
<br />CPTT-1
<br />-
<br />P-1
<br />P-1
<br />P-1
<br />P-1
<br />GWB, P-3
<br />102
<br />CLASSROOM 2
<br />RPT-1
<br />RB-1
<br />P-1
<br />P-1
<br />P-1
<br />P-1
<br />ACP-2
<br />PLAM-2
<br />PLAM-1
<br />REFERENCE FINISH PLAN & ELEVATIONS
<br />FOR FRP EXTENTS
<br />102A
<br />CHILDREN'S TLT
<br />RSF-1
<br />IB
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FPR-1, P-1
<br />ACP-1
<br />PLAM-2
<br />PLAM-1
<br />103
<br />CLASSROOM 3
<br />RPT-1
<br />RB-1
<br />P-1
<br />P-1
<br />P-1
<br />P-1
<br />ACP-2
<br />PLAM-2
<br />PLAM-1
<br />REFERENCE FINISH PLAN & ELEVATIONS
<br />FOR FRP EXTENTS
<br />103A
<br />CHILDREN'S TLT
<br />RSF-1
<br />IB
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FPR-1, P-1
<br />ACPA
<br />PLAM-2
<br />PLAM-1
<br />104
<br />HOS
<br />CPTT-1
<br />RB-1
<br />P-1
<br />P-1
<br />P-1
<br />P-1
<br />ACP-2
<br />105
<br />WARMING KITCHEN
<br />RSF-1
<br />IB
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FPR-1, P-1
<br />ACPA
<br />FRP TO 5'-0" AFF
<br />106
<br />STAFF LOUNGE
<br />CPTT-1
<br />RB-1
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />FPR-1, P-1
<br />ACP-2
<br />107
<br />CUST.
<br />RSF-1
<br />IB
<br />P-1
<br />FRP-1, P-1
<br />FRP-1, P-1
<br />P-1
<br />GWB, P-3
<br />REFERENCE FINISH PLAN & ELEVATIONS
<br />FOR FRP EXTENTS
<br />WALL PER
<br />PLAN
<br />(066400) REINFORCED
<br />FIBER PANEL (FRP-1),
<br />AS OCCURS
<br />(096500) 4" RESILIENT
<br />WALL BASE, (RB-1)
<br />(096800) CARPET
<br />TILE, (CPTT-1) OR
<br />ENTRANCE CARPET
<br />MAT (EM-1)
<br />CARPET (CPTT-1/EM-1) W/
<br />RESILIENT WALL BASE
<br />WALL PER
<br />PLAN
<br />(096500) 4" RESILIENT
<br />WALL BASE, (RB-1)
<br />(096500) RESILIENT
<br />PLANK TILE (RPT-1)
<br />RESILIENT PLANK TILE (RPT-1)
<br />W/ RESILIENT WALL BASE
<br />TYPICAL WALL BASE
<br />3" = 1'-01,
<br />V I DOOR PANEL
<br />(WHERE OCCURS)
<br />I
<br />(096500) RESILIENT
<br />TRIM
<br />(096800) CARPET I (096500) RESILIENT
<br />TILE (CPTT-1) FLOORING (RPT-1,
<br />77, RSF-1)
<br />TT-1, TRANSITION CENTER TRANSITION
<br />TYPE 1 BENEATH DOOR PANEL, TYP
<br />DOOR PANEL
<br />(WHERE OCCURS)
<br />(096500)
<br />(096800) CARPET RESILIENT TRIM
<br />TILE (CPTT-1) I (096800) ENTRANCE
<br />N CARPET (EM-1)
<br />TT-2, TRANSITION �-
<br />TYPE 2 CENTER TRANSITION
<br />BENEATH DOOR PANEL, TYP
<br />v DOOR PANEL
<br />(WHERE OCCURS)
<br />I
<br />(096500) RESILIENT
<br />x
<br />T-MOLDING
<br />(096500) RESILIENT Lj
<br />I (096500) RESILIENT
<br />FLOORING (RPT-1) <= FLOORING (RSF-1)
<br />as a
<br />TT-3, TRANSITION CENTER TRANSITION
<br />TYPE 3 BENEATH DOOR PANEL, TYP
<br />(096500) RESILIENT
<br />TRANSITION JOINER
<br />a
<br />(096500) RESILIENT EXISTING TERRAZZO
<br />FLOORING (RPT-1) .=
<br />- a - - .° - a - � •.nix - - - m� _, d ....> -..-..
<br />TT-3, TRANSITION
<br />TYPE 4
<br />FLOOR FINISH TRANSITION DETAIL
<br />6" = 1'-0"
<br />WALL PER
<br />PLAN
<br />II�1►r1
<br />!600) CORNER
<br />kRD,
<br />TALLED PER
<br />2
<br />WALL PER
<br />PLAN
<br />(066400) REINFORCED
<br />I FIBER PANEL (FRP-1),
<br />AS OCCURS
<br />METAL TRIM
<br />r(096500) 4" INTEGRAL
<br />COVE BASE
<br />(096500) RESILIENT SHEET
<br />l- FLOORING (RSF-1)
<br />RESILIENT SHEET FLOORING
<br />(RSF-1) W/ INTEGRAL WALL BASE
<br />(102600) CORNER
<br />GUARD
<br />RESILIENT WALL
<br />BASE, PER
<br />SCHEDULE
<br />FINISHED FLOOR,
<br />PER PLAN
<br />SECTION ELEVATION
<br />3" = 1'-0"
<br />RESILIENT
<br />OUTSIDE CORNER
<br />TRIM, TO MATCH
<br />PANEL
<br />FRP-1
<br />PLAN VIEW AT
<br />OUTSIDE CORNER
<br />WALL PER
<br />PLAN, TYP.
<br />SEALANT
<br />RESILIENT EDGE TRIM,
<br />TO MATCH PANEL
<br />SEALANT
<br />FRP-1
<br />HORIZONTALIVERTICAL EDGES
<br />FRP-1 (AS
<br />OCCURS)
<br />SEALANT
<br />CORNER
<br />GUARD
<br />SEALANT
<br />FRP-1
<br />PLAN VIEW AT OUTSIDE
<br />CORNER W/ CORNER GUARD
<br />RESILIENT INSIDE
<br />CORNER TRIM, TO
<br />MATCH PANEL
<br />FRP-1
<br />PLAN VIEW AT INSIDE CORNER
<br />TYPICAL FRP DETAIL
<br />3" 1'-0"
<br />F. "v ,.+'
<br />I
<br />,
<br />�.�
<br />1/8" = 1'-0"
<br />CPTT-1 CARPET TILE (096800)
<br />EM-1 ENTRANCE CARPET MAT (096800)
<br />-- -- ------ RPT-1 RESILIENT PLANK TILE (096500)
<br />---- ----- --- (DIRECTION INDICATED W/ SYMBOL)
<br />RSF-1 RESILIENT SHEET FLOORING (096500)
<br />1. HOLLOW METAL DOOR FRAMES AND WOODEN DOOR
<br />FRAMES TO BE PAINTED P-2.
<br />2. WINDOW SILLS AND WINDOW FRAMES TO BE PAINTED P-2.
<br />3. TILE TO BE INSTALLED CENTERED ON ROOM TYP, UNO.
<br />4. WALLS TO BE PAINTED P-1 TYP, UNO.
<br />FINISH PLAN ABBREVIATION
<br />EXISTING FLOORING TO REMAIN
<br />laa
<br />ACP
<br />ACOUSTICAL CEILING PANEL
<br />IB
<br />AFF
<br />ABOVE FINISH FLOOR
<br />OFCI
<br />F -
<br />CL
<br />CENTER LINE
<br />CONC
<br />CONCRETE
<br />OFOI
<br />I I
<br />NOT IN SCOPE
<br />CPTT
<br />CARPET TILE
<br />L -
<br />(E)
<br />EXIST / EXISTING
<br />P
<br />EM
<br />ENTRANCE CARPET MAT
<br />PLAM
<br />ES
<br />EXPOSED TO STRUCTURE
<br />RB
<br />- - - - - - - - - - -
<br />FRP-1 FIBER REINFORCED PANEL (066400)
<br />FOF
<br />FACE OF FINISH
<br />RPT
<br />FRP
<br />FIBER REINFORCED PANEL
<br />RSF
<br />GWB
<br />GYPSUM WALL BOARD
<br />SS
<br />CG-#
<br />CORNER GUARD
<br />GYP
<br />GYPSUM
<br />TT
<br />HM
<br />HOLLOW METAL
<br />VIF
<br />TT-#
<br />TRANSITION TYPE
<br />FLOOR PATTERN DIRECTION SYMBOL
<br />INTEGRAL BASE (COVE)
<br />OWNER FURNISHED,
<br />CONTRACTOR INSTALLED
<br />OWNER FURNISHED, OWNER
<br />INSTALLED
<br />PAINT
<br />PLASTIC LAMINATE
<br />RESILIENT BASE
<br />RESILIENT PLANK TILES
<br />RESILIENT SHEET FLOORING
<br />STAINLESS STEEL
<br />TRANSITION TYPE
<br />VERIFY IN FIELD
<br />bassetti
<br />architects
<br />71 Columbia Street, Suite 500
<br />Seattle, Washington 98104
<br />T (206) 340 9500
<br />www.bassettiarch.com
<br />MECHANICAL ENGINEER
<br />FSi
<br />1001 Alaskan Way, Suite 200
<br />Seattle WA 98104
<br />T (206) 385 6124
<br />ELECTRICAL ENGINEER
<br />Hargis
<br />1201 Third Avenue, Suite 600
<br />Seattle WA 98101
<br />T (206) 436 0457
<br />FOOD SERVICE
<br />JLR Design Group
<br />557 Roy St. Suite 175-A
<br />Seattle, WA 98109
<br />T (206) 625 0070
<br />ONE INCH
<br />AT FULL SIZE
<br />This document has been digitally signed
<br />5428
<br />F
<br />ST"R': �
<br />ARCji
<br />ITECT
<br />QA"4 1, V
<br />DANIEL MILES
<br />s TL o>{ wz�sxIr t ora
<br />05/12/2022 3:04:33
<br />PM
<br />REVISIONS DATE
<br />Owner
<br />BEZOS ACADEMY -
<br />EVERETT TRANSIT
<br />STATION
<br />3291 SMITH AVE.
<br />EVERETT WA 98201
<br />JOB NO: 2018
<br />ISSUE DATE: 05/12/22
<br />Jurisdiction Stamp Area
<br />FINISH FLOOR
<br />PLANS