My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3201 SMITH AVE 2022 BEZOS ACADEMY Plans 2023-01-09
>
Address Records
>
SMITH AVE
>
3201
>
BEZOS ACADEMY
>
Plans
>
3201 SMITH AVE 2022 BEZOS ACADEMY Plans 2023-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2023 8:19:40 AM
Creation date
12/15/2022 2:55:50 PM
Metadata
Fields
Template:
Address Document
Street Name
SMITH AVE
Street Number
3201
Tenant Name
BEZOS ACADEMY
Permit
B2205-053
PW2205-024
Year
2022
Notes
TI: (3) CLASSROOM PRESCHOOL ON 1ST FLOOR OF TRANSIT BLDG ; SITE WORK FOR BEZOS ACADEMY
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING ELECTRICAL TO BE REMOVED <br />®® MATCHLINE OR PROPERTY LINE <br />®®®® ENLARGED PLAN BOUNDARY <br />SWITCHBOARD/SWITCHGEAR <br />._._ <br />PANELBOARD, FLUSH -MOUNTED <br />- - <br />PANELBOARD, SURFACE -MOUNTED <br />(FRONT) <br />�, <br />TRANSFORMER <br />MOTOR CONNECTION <br />DISCONNECT SWITCH, NON -FUSED <br />DISCONNECT SWITCH, FUSED <br />8 <br />ENCLOSED CIRCUIT BREAKER <br />M <br />MANUAL MOTOR STARTER WITH THERMAL <br />OVERLOADS <br />COMBINATION STARTER/DISCONNECT <br />MAGNETIC STARTER. <br />f: EQUIPMENTiCONFIRM CONNECTION <br />MANUFACTURERWITH EQUIPMENT <br />J F/S FIRE/SMOKE DAMPER <br />EMERGENCY POWER OFF PUSHBUTTON <br />PIP <br />21 <br />7 <br />A <br />a I <br />N <br />04 <br />GROUNDING <br />—G <br />GROUNDING CONDUCTOR <br />® <br />GROUND ROD <br />GROUNDING BUSBAR <br />EQUIPMENT GROUNDING CONNECTION <br />GROUNDING STRAP <br />,JUNCTION BOX <br />HANDHOLE <br />HH <br />XX (WHERE INDICATED, SUBSCRIPT INDICATES UTILITY VAULT TYPE) <br />RACEWAY CONCEALED IN WALL OR IN CEILING <br />(EXPOSED IN UNFINISHED AREAS) <br />RACEWAY RUN BELOW FLOOR OR BELOW GRADE <br />RACEWAY (CIRCLE DENOTES VERTICAL <br />TRANSITION) <br />RACEWAY CONTINUATION <br />RACEWAY STUB WITH BUSHING <br />HOMERUN TO PANEL <br />HA-3(INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER) <br />10 (GAUGE OF WIRE OTHER THAN AWG#12) <br />NUMBER OF CONDUCTORS <br />(GROUND CONDUCTOR) <br />(PHASE CONDUCTORS) <br />(NEUTRAL CONDUCTOR) <br />TELECOMMUNICATIONS DEVICE <br />W/1(X m REPRESENTS THE # OF TELECOMMUNICATIONS MODULES) <br />(W ® TELECOMMUNICATIONS WALL PHONE MTD AT +43" AFF) <br />(B = BLANK COVER PLATE) <br />1(F = MODULAR FURNITURE DEVICE) <br />(AC = ABOVE COUNTER DEVICE) <br />(WAP = WIRELESS ACCESS POINT DEVICE MTD AT -12° BELOW CLG) <br />ABOVE CEILING TELECOMMUNICATIONS DEVICE <br />(X = REPRESENTS THE # OF TELECOMMUNICATIONS MODULES) <br />WAP(WAP = WIRELESS ACCESS DEVICE) <br />(SV = SECURITY VIDEO CAMERA) <br />FIRE RESISTANT 3/4" PLYWOOD BACKBOARD <br />® WALL MOUNTED ENCLOSURE <br />DEFINED BY SUBSCRIPT <br />a = SWITCH LEG <br />T = TIMER <br />3 = THREE WAY <br />4 = FOUR WAY <br />P = PILOT LIGHT <br />K = KEYED <br />LV = LOW VOLTAGE <br />D = DIMMER <br />OS = OCCUPANCY SENSOR <br />ANY COMBINATION OF SWITCH TYPES CAN BE # <br />I f S b r. fl <br />A <br />DEVICE SUBSCRIPTS <br />a <br />(LIGHT FIXTURE TYPE) <br />12 ----(SWITCHLEG) <br />(CIRCUIT NUMBER) <br />0 <br />LIGHTING FIXTURES <br />(REFER TO LIGHTING FIXTURE SCHEDULE <br />FOR ADDITIONAL INFORMATION) <br />0 El <br />STRIP LIGHTING FIXTURE <br />WALL -MOUNTED LIGHTING FIXTURE <br />EMERGENCY LIGHTING FIXTURES <br />r <br />(REFER TO LIGHTING FIXTURE SCHEDULE <br />FOR ADDITIONAL INFORMATION) <br />oil <br />OHM <br />SELF-CONTAINED BATTERY -POWERED EMERGENCY <br />LIGHTING FIXTURE <br />EXIT SIGN, UNIVERSAL MOUNTING <br />(SHADED AREA INDICATES DIRECTION ARROWS) <br />EXIT SIGN, WALL -MOUNTED <br />(SHADED AREA INDICATES DIRECTION ARROWS) <br />IP SECURITY VIDEO <br />SYSTEM <br />CAMERA,O, l <br />* 1; <br />ACP ACCESS CONTROL PANEL <br />CREDENTIAL/ CARD READER, MOUNTED AT +48" <br />S I(CR = CARD READER, WALL MOUNTED) <br />cR (CR/P = CARD READER W/PIN, WALL MOUNTED) <br />(CR/M = CARD READER, MULLION MOUNTED) <br />S DOOR. POSITION SWITCH <br />SECURITY BUTTONS/SWITCH, WALL MOUNTED AT +43" <br />S (AO = AUTO OPERATOR) <br />(DR = DOOR RELEASE) <br />XX (LD = LOCKDOWN) <br />(KS = KEYED SWITCH <br />(PB = PANIC/ DURESS) <br />Ps DOOR HARDWARE POWER SUPPLY <br />EL ELECTRIFIED HARDWARE <br />(EL = ELECTRIFIED LOCKSET/EXIT DEVICE) <br />(ES = ELECTRIFIED STRIKE) <br />(ML = ELECTRIFIED MAGNETIC LOCK) <br />(MH = ELECTRIFIED MAGNETIC HOLD OPEN) <br />DE DOOR ENTRY INTERCOM VIDEO STATION <br />MS DOOR MASTER STATION, DESK TOP <br />DI DOOR CHIME <br />!OT ALL SYMBOLS MAY APPEAR ON THE DRAWING,' <br />m <br />E0,01 ELECTRICAL LEGEND AND DRAWING INDEX <br />E0.02 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES <br />E0.03 ELECTRICAL AND SECURITY SCHEDULES <br />ED2.01 LIGHTING DEMOLITION FLOOR PLAN <br />ED3.01 ELECTRICAL DEMOLITION FLOOR FLAN <br />ED6.01 LOW -VOLTAGE & FIRE ALARM DEMOLITION FLOOR <br />PLAN <br />E2.01 LIGHTING FLOOR PLAN <br />E2,01A LIGHTING CONTROL ZONE FLOOR PLAN <br />E3.01 POWER FLOOR PLAN <br />E6.01 LOW -VOLTAGE & FIRE ALARM FLOOR PLAN <br />E6.02 TELECOM & SECURITY PLANS & ELEVATIONS <br />E3.01 LOIN -VOLTAGE DETAILS <br />E9.01 ELECTRICAL ONE -LINE DIAGRAM <br />E10.01 PANEL SCHEDULES <br />Washington71 Columbia Street, Suite 500 <br />+ <br />6 5l <br />wwui.Wassettiarch.com <br />� <br />= wa <br />fla <br />FTIMMAM <br />REVISIONS DATE <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />JOB NO: 2013 <br />ISSUE [GATE: 5/12/2022 <br />JUrisdicti®n Stamp Area <br />F1. <br />
The URL can be used to link to this page
Your browser does not support the video tag.