Laserfiche WebLink
TRANSFORMER SUMMARY: 05/09/2022 <br />(E) TRANSFORMER -T-TBN' <br />PR03ECT: Bezos Everett Station <br />CLASSIFICATION: NORMAL <br />PRIMARY VOLTAGE: 48OV 30, 3-WIRE <br />FED FROM: (E) MAIN SWITCHBOARD WDP' <br />SECONDARY VOLTAGE: 208YA 20V 30, 4-WIRE <br />KVA RATING: 225 KVA <br />LOAD CALCULATIONS <br />LOAD DESCRIPTION <br />CONNECTED LOAD <br />- <br />DEMAND <br />x <br />FACTOR <br />125% <br />CALCULATED LOAD <br />MISCELLANEOUS CONTINUOUS: <br />EQUIPMENT & MISCELLANEOUS: <br />47160 <br />x <br />1000/0 <br />47160 <br />LIGHTING: <br />1750 <br />x <br />125% <br />2188 <br />LARGEST MOTOR- <br />1660 <br />x <br />125% <br />2075 <br />MOTORS. <br />7840 <br />x <br />1000/0 <br />7840 <br />RECEPTACLE: <br />10000 <br />x <br />1000/0 <br />10000 <br />RECEPTACLES OVER 1011WA- <br />97380 <br />x <br />500/0 <br />48690 <br />APPLIANCE. <br />3000 <br />x <br />1000/0 <br />3000 <br />COMPUTER: <br />10000 <br />x <br />1000/0 <br />10000 <br />KITCHEN (EQUIP = 12): <br />27544 <br />x <br />650/0 <br />17904 <br />LOAD SUMMARY <br />TOTAL PRIMARY SECONDARY <br />TOTAL CONNECTED LOAD (VA) <br />TOTAL CALCULATED LOAD (VA) <br />CONNECTED LOAD AMPS AMPS <br />206, <br />��857 VA <br />PHASE A: 72,41 OVA 261 A 603 A <br />PHASE B: 71,285 VA 257 A 594 A <br />TOTAL CONNECTED AMPS <br />TOTAL CALCULATED AMPS <br />PHASE C: 62,639 VA 226 A 522 A <br />PRI. 248 A SEC: 573 A <br />I PRI: 179 A SEC: 413 A <br />NOTES: <br />HARGIS ENGINEERS, INC. <br />1. <br />1201 THIRD AVENUE, SUITE 600 <br />2. <br />SEATTLE, WA 98101 <br />3. <br />4. <br />PH. (206) 448-3376 <br />5, <br />FAX. (206) 448-4450 <br />PANEL SCHEDULE: 05109/2022 <br />(E) PANEL "I HN' <br />PROJECT: Bezos Everett Station <br />CLASSIFICATION: NORMAL <br />FED FROM- (F) MAIN SWITCH BOAR D'M DP' <br />MOUNTING: SURFACE <br />VOLTAGE: 480Y/277V 30, 4-WIRE <br />MAINS- 225A MAIN LUGS ONLY <br />NEUTRAL: 100% RATED <br />SECTION: 1 OF 1 <br />NOTE <br />ITEM DESCRIPTION <br />CKT <br />NO. <br />BREAKER <br />LOAD <br />I (VA) <br />0 <br />LOAD <br />(VA) <br />BREAKER <br />CKT <br />NO. <br />ITEM DESCRIPTION <br />NOT <br />AMP <br />POLE <br />AMP <br />POLE <br />I <br />LIGHTING - TENANT SPACE <br />1 <br />20 <br />1 <br />1962 <br />A <br />4307 <br />25 <br />3 <br />2 <br />FPS 1-2 <br />2 <br />SPARE <br />3 <br />20 <br />1 <br />B <br />4307 <br />- <br />- <br />SPARE <br />5 <br />20 <br />1 <br />C <br />4307 <br />- <br />- <br />6 <br />IFPB 1-2A <br />7 <br />1 20 <br />3 <br />2307 <br />A <br />4307 <br />25 <br />3 <br />8 <br />FPB 1-3 <br />9 <br />- <br />- <br />2307 <br />B, <br />4307 <br />- <br />- <br />10 <br />11 <br />- <br />- <br />2307 <br />C <br />4307 <br />- <br />- <br />12 <br />FPB 1-3A <br />13 <br />20 <br />3_ <br />2307 <br />A <br />2057 <br />20 <br />3 <br />1 14 <br />FPB 1-4 <br />15 <br />- <br />- <br />2307 <br />B <br />2057 <br />- <br />- <br />16 <br />- <br />17 <br />- <br />- <br />2307 <br />C <br />2057 <br />- <br />- <br />18 <br />r <br />FPB-1-5A <br />19 <br />20 <br />3 <br />1 1453 <br />A <br />2973 <br />20 <br />3 <br />20 <br />FPB 1-5 <br />21 <br />- <br />- <br />1453 <br />B <br />2973 <br />- <br />- <br />22 <br />r <br />23 <br />- <br />- <br />1453 <br />C <br />2973 <br />- <br />- <br />24 <br />25 <br />20 <br />1 <br />Al <br />1453 <br />20 <br />3 <br />26 <br />FPB 1-6 <br />SPARE <br />27 <br />20 <br />1 <br />B <br />1453 <br />- <br />- <br />28 <br />SPARE <br />29 <br />20 <br />1 <br />C <br />1453 <br />- <br />- <br />30 <br />r <br />SPARE <br />31 <br />20 <br />1 <br />A <br />627 <br />20 <br />3 <br />32 <br />FPB 1-17 <br />33 <br />20 <br />1 <br />B <br />627 <br />- <br />- <br />34 <br />1 <br />35 <br />20 <br />1 1 <br />C <br />627 <br />- <br />- <br />36 <br />37 <br />20 <br />1 <br />1 <br />A <br />20 <br />1 <br />38 <br />39 <br />±20 <br />1 <br />1 <br />le <br />20 <br />1 <br />40 <br />41 <br />1 20 <br />1 1 <br />1 <br />ICI <br />2 <br />LOAD CALCULATIONS <br />LOAD DESCRIPTION <br />CONN. (VA) DEMAND FACTOR CALL. (VA) <br />MISCELLANEOUS CONTINUOUS: <br />EQUIPMENT & MISCELLANEOUS: <br />LIGHTING: <br />LARGEST MOTOR: <br />MOTORS: <br />RECEPTACLE: <br />RECEPTACLES OVER 10VVA: <br />TOTALS: <br />- <br />1962 <br />12921 <br />52452 <br />- <br />125% <br />100% <br />1250/a <br />125% <br />100% <br />100% <br />- <br />2453 <br />16151 <br />52452 <br />- <br />LOAD SUMMARY <br />TOTAL <br />CONNECTEDLOAD AMPS <br />PHASE A: 23,753 VA. 86A <br />PHASE B: 21791 VA 79A <br />PHASE C: 21,791 VA 79A <br />TOTAL CALCULATED LOAD: 71,056VA <br />TOTAL CALCULATED AMPS: 86A <br />l 67,335 71,056 <br />NOTES: PANEL HAS A NET LOAD REDUCTION OF —2KVA <br />1. LOAD ON CIRCUIT IS A NET LOAD REDUCTION OF 500VA. <br />2. CIRCUIT RENDERED SPARE BY SELECTIVE DEMOLITION ACTIVITIES. <br />3. <br />4. <br />5- <br />HARGIS ENGINEERS, INC <br />1201 THIRD AVENUE, SUITE 600 <br />SEATTLE, WA 98101 <br />PH. (206) 448-3376 <br />FAX. (206) 448-4450 <br />co <br />CN <br />M <br />N <br />DIST. PANEL SUMMARY. 05/0912022 <br />(E) DI T. PANEL 'SDPN' <br />PROJECT: Bezos Everett Station <br />C <br />CLASSIFICATION: NORMAL <br />VOLTAGE: 208YI12OV30,4-WIRE <br />FED FROM: (E) TRANSFORMER 'T-TBN' <br />MAINS: 600A MAIN CIRCUIT BREAKER <br />rNE <br />MOUNTING: FIELD VERIFY <br />RA 0% RATED <br />UT L 1 0 <br />LOAD CALCULATIONS <br />LOAD DESCRIPTION <br />CONNECTED LOAD <br />- <br />x <br />DEMAND FACTOR <br />125% <br />CALCULATED LOAD <br />MISCELLANEOUS CONTINUOUS: <br />EQUIPMENT & MISCELLANEOUS: <br />47160 <br />x <br />1000/0 <br />47160 <br />LIGHTING: <br />1750 <br />x <br />125% <br />2188 <br />LARGEST MOTOR: <br />1660 <br />x <br />125% <br />2075 <br />MOTORS: <br />7840 <br />x <br />1000/0 <br />7840 <br />RECEPTACLE: <br />10000 <br />x <br />1000/0 <br />m 10000 <br />RECEPTACLES OVER 10kVA: <br />97380 <br />x <br />50010 <br />48690 <br />APPLIANCE: <br />3000 <br />x <br />1000/0 <br />a 3000 <br />COMPUTER: <br />10000 <br />x <br />1000/0 <br />10000 <br />KITCHEN (EQUIP 12): <br />27544 <br />x <br />650/0 <br />m 17904 <br />LOAD SUMMARY <br />TOTAL <br />TOTAL CONNECTED LOAD (VA) <br />TOTAL CALCULATED LOAD (VIA) <br />CONNECTED LOAD AMPS <br />206,334 VA <br />148,857 VA <br />PHASE A: 72A 10 VA 6303 A <br />PHASE B: 71,285 VA 594 A <br />TOTAL CONNECTED AMPS <br />TOTAL CALCULATED AMPS <br />PHASE C: 62,639 VA 522 A <br />573A <br />E 413 <br />NOTES: <br />HARGIS ENGINEERS, INC. <br />1. <br />1201 THIRD AVENUE, SUITE 600 <br />2. <br />SEATTLE, WA 98101 <br />3. <br />4. <br />PH. (206) 448-3376 <br />5. <br />FAX. (206) 448-4450 <br />PANEL SCHEDULE: 0510912022 <br />(E) PANEEC. 'ILN' <br />PROJECT: Bezos Everett Station <br />CLASSIFICATION: NORMAL <br />FED FROM: (F) DIST- PANFL'SDPN' <br />MOUNTING: SURFACE <br />VOLTAGE: 208Y/120V 30,4-WIRE <br />MAINS- 225A MAIN LUGS ONLY <br />NEUTRAL: 100% RATED <br />SECTION: 1 OF I <br />NOTE <br />ITEM DESCRIPTION <br />CKT <br />NO. <br />BREAKER <br />LOAD <br />(VA) <br />0 <br />LOAD <br />(VA) <br />BREAKER <br />CKT <br />NO. <br />ITEM DESCRIPTION <br />NOTE <br />AMP <br />­POLE <br />AMP <br />POLE <br />1,3 <br />RECEPTACLES <br />1 <br />20 <br />1 <br />360 <br />A <br />180 <br />20 <br />1 1 <br />2 <br />RECEPTACLES - INTERVIEW 111, 112 <br />1,3 <br />RECEPTACLES <br />3 <br />20 <br />1 <br />360 <br />B <br />360 <br />20 <br />1 <br />4 <br />RECEPTACLES - WORKSHOP 110 <br />1,3 <br />RECEPTACLES <br />5 <br />20 <br />1 <br />720 <br />C <br />900 <br />20 <br />1 <br />6 <br />RECEPTACLES - WORKSHOP 110 <br />1,3 <br />RECEPTACLES + BOTTLE FILLER <br />7 <br />20 <br />1 <br />1000 <br />A <br />500 <br />20 <br />1 <br />8 <br />EF-1,2 <br />1 <br />1,3 <br />CONVENIENCE RECEPTACLES <br />9 <br />20 <br />1 <br />1 180 <br />B <br />1 1000 <br />20 <br />1 <br />1 10 <br />IDIF <br />1 <br />3 <br />ISPARE <br />11 <br />20 <br />1 <br />C <br />250 <br />20 <br />1 <br />12 <br />ACCESS CONTROL POWER SUPPLY <br />1 <br />3 <br />SPARE <br />13 <br />20 <br />1 <br />A <br />250 <br />1 20 <br />1 <br />14 <br />DOOR HARDWARE POWER SUPPLY <br />1 <br />1,3 <br />RECEPTACLES - STAFF LOUNGE <br />15 <br />20 <br />1 <br />720 <br />0 <br />250 <br />20 <br />1 <br />16 <br />NAC PANEL <br />1,4 <br />1,3 <br />1-DOOR REFRIGERATOR <br />17 <br />20 <br />1 <br />504 <br />C <br />180 <br />20 <br />1 <br />18 <br />RECEPTACLE -JANITORS CLOSET <br />1 <br />1,3 <br />WORK -TOP FREEZER <br />19 <br />20 <br />1 <br />540 <br />A <br />1500 <br />30 <br />2 <br />20 <br />IDRYER <br />2 <br />3 <br />SPARE <br />21 <br />20 <br />1 <br />B <br />1500 <br />- <br />- <br />22 <br />- <br />,RECEPTACLES - CDC 114 <br />23 <br />1 20 <br />1 <br />1 900 <br />C <br />m <br />24 <br />SPACE <br />IRECEPTACLES - CDC 114 <br />25 <br />20 <br />1 <br />540 <br />A <br />26 <br />SPACE <br />RECEPTACLES - CDC 114 RECEPTION <br />27 <br />20 <br />1 <br />540 <br />B <br />28 <br />SPACE <br />RECEPTACLES -CDC 114 RECEPTION <br />29 <br />20 <br />1 <br />540 <br />C <br />6250 <br />50 <br />2 <br />30 <br />RANGE <br />2- <br />RECEPTACLES - ORIENTATION 115 <br />31 <br />20 <br />1 <br />900 <br />A <br />6250 <br />- <br />- <br />32 <br />RECEPTACLES -ORIENTATION 115 <br />33 <br />20 <br />1 <br />1060 <br />B <br />2425 <br />30 <br />2 <br />34 <br />RETHERM CABINET <br />2 <br />SPARE <br />35 <br />20 <br />1 <br />C, <br />2425 <br />- <br />- <br />36 <br />- <br />1 <br />1,3 <br />CONVENIENCE RECEPTACLES <br />37 <br />20 <br />1 <br />180 <br />A <br />- <br />- <br />38 <br />SPACE <br />1 <br />1,3 <br />CONVENIENCE RECEPTACLES <br />39 <br />20 <br />1 <br />180 <br />B <br />2100 <br />30 <br />1 <br />40 <br />UNDERCOUNTER <br />2 <br />1 <br />RESIDENTIAL MICROWAVE EXHAUST HOOD <br />_ <br />41 <br />20 <br />1 <br />1800 <br />:C]_—= <br />42 <br />-DISHWASHER <br />SPACE <br />LOAD CALCULATIONS <br />LOAD DESCRIPTION <br />CONN. (VA) DEMAND FACTOR CALC. (VA) <br />MISCELLANEOUS CONTINUOUS: <br />EQUIPMENT & MISCELLANEOUS: <br />LIGHTING: <br />LARGEST MOTOR: <br />MOTORS: <br />RECEPTACLE: <br />RECEPTACLES OVER 1 OkVA: <br />APPLIANCE: <br />KITCHEN (LARGEST 2): <br />TOTALS:, <br />- <br />1750 <br />- <br />500 <br />- <br />9800 <br />- <br />3000 <br />22294 <br />125% <br />100% <br />125% <br />125% <br />100% <br />100% <br />50% <br />100% <br />78% <br />- <br />1750 <br />- <br />625 <br />- <br />9800 <br />- <br />3000 <br />17350 <br />LOAD SUMMARY <br />TOTAL <br />CONNECTED LOAD AMPS <br />PHASE A: 12,200 VA 102 A <br />PHASE B: 10,675 VA 89A <br />PHASE C: 14,469 VA 121 A <br />TOTAL CALCULATED LOAD: 32,525 VA <br />TOTAL CALCULATED AMPS: 90 A <br />37,344 32,525 <br />NOTES: <br />1. NEW LOAD ON EXISTING SPARE BREAKER. <br />2. PROVIDE SPARE CIRCUIT BREAKER IN AVAILABLE SPACE INDICATED. <br />3. CIRCUIT RENDERED SPARE BY SELECTIVE DEMOLITION. <br />4. PROVIDE LOCKABLE TYPE CIRCUIT BREAKER KIT. <br />5. <br />HARGIS ENGINEERS, INC, <br />1201 THIRD AVENUE, SUITE 600 <br />SEATTLE, WA 98101 <br />PH. (206) 448-3376 <br />FAX. (206) 448-4450 <br />I <br />WIMP <br />mm <br />71 Columbia Street, Suite 500 <br />Seattle, Washington 98104 <br />T (206) 340 9500 <br />uitiv. bwsettiarcW.cors. <br />MECHANICAL ENGINEER <br />FSi <br />1001 Alaskan Way, Suite 200 <br />Seattle WA 98104 <br />T (206) 385 6124 <br />ELECTRICAL ENGINEER <br />Hargis <br />1201 Third Avenue, Suite 600 <br />Seattle WA 98101 <br />T (206) 436 0457 <br />FOOD SERVICE <br />JLR Design Group <br />557 Roy St, Suite 175-A <br />Seattle, WA 98109 <br />T (206) 625 0070 <br />& REVISIONS DATE <br />"row <br />■ Out � WARM "Iff I— <br />3291 SMITH AVE. <br />EVERETT WA 98201 <br />KIM <br />ISSUE DATE: 5/12/2022 <br />Jurisdiction Stamp Area <br />SCHEDULES <br />