My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
15 SW EVERETT MALL WAY 2022 NOVEL EYES Plans 2023-01-09
>
Address Records
>
SW EVERETT MALL WAY
>
15
>
NOVEL EYES
>
Plans
>
15 SW EVERETT MALL WAY 2022 NOVEL EYES Plans 2023-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2023 8:03:03 AM
Creation date
12/15/2022 3:29:36 PM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
15
Tenant Name
NOVEL EYES
Permit
B2203-038
Year
2022
Notes
2306 SF OFFICE REMODEL TO EYE CLINIC
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LOCATION <br />xxxx DOOR <br />TRIM <br />LOCK <br />FUNCTION <br />REMARKS/ACCESSORIES <br />NO. <br />SIZE <br />TYPE <br />MAT'L <br />FINISH <br />TYPE <br />MAT'L <br />FINISH <br />100-LOBBY <br />IOOA <br />EXISTING <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />- <br />EXISTING <br />VERIFY RE -KEYING WITH CLIENT <br />101-OFFICE <br />101A <br />EXISTING <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />105-PRE-TEST <br />& SPECIAL TESTING <br />105A <br />EXISTING <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />106-LANE 1 <br />106A <br />EXISTING <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />107-LANE 2 <br />107A <br />EXISTING <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />108-LANE 3 <br />108A <br />3'-0" X 7'-0" X 1-3/4" <br />SC WOOD <br />STAIN <br />0 <br />WOOD <br />STAIN <br />PASSAGE <br />FLOOR STOP <br />109-LANE 4 <br />109A <br />3'-O" X 7'-0" X 1-3/4" <br />SC WOOD <br />STAIN <br />01 <br />WOOD <br />STAIN <br />PASSAGE <br />FLOOR STOP <br />110-STAFF LOUNGE <br />110A <br />EXISTING <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />- <br />EXISTING <br />- <br />111-LAB <br />111A <br />3'-1" X 7'-0" X 1-3/4" <br />BD <br />SC WOOD <br />PAINT P-1 <br />Q <br />WOOD <br />PAINT P-1 <br />POCKET <br />- <br />111-LAB <br />111B <br />3'-O" X 7'-0" X 1-3/4" <br />DA <br />HM <br />PAINT P-1 <br />02 <br />HM <br />PAINT P-1 <br />LOCKSET B <br />VERIFY TO MATCH BUILDING EXTERIOR DOOR STANDARD, HOLLOW METAL INSULATED DOOR. (PULL SIDE) <br />CLOSER, CONCEALED OVERHEAD STOP ARM. VERIFY KEYING WITH CLIENT. SEE A1.1 FOR THRESHOLD DETAIL <br />MAXIMUM U-FACTOR = 0.37 PER TABLE C402.1.4. <br />112-OFFICE <br />112A <br />3'-0" X 7'-0" X 1-3/4" <br />0 <br />SC WOOD <br />STAIN <br />Q <br />WOOD <br />STAIN <br />LOCKSET A <br />FLOOR STOP <br />113-RESTROOM <br />113A <br />3'-0" X 7'-0" X 1-3/4" <br />DA <br />SC WOOD <br />STAIN <br />Q <br />WOOD <br />STAIN <br />PRIVACY <br />STANDARD (PULL SIDE) CLOSER, CONCEALED OVERHEAD STOP ARM, DOOR BOTTOM #1, SOUND SEAL <br />114-RESTROOM <br />114A <br />3'-0" X 7'-0" X 1-3/4" <br />® <br />SC WOOD <br />PAINT P-1 <br />01 <br />WOOD <br />PAINT P-1 <br />PRIVACY <br />STANDARD (PULL SIDE) CLOSER, CONCEALED OVERHEAD STOP ARM, DOOR BOTTOM #1, SOUND SEAL. APPLY <br />SUITABLE WATER/MOISTURE RESISTANT PAINT FOR DOOR AND TRIM FOR WET CONDITIONS. VERIFY WITH CLIENT. <br />DOOR HARDWARE SCHEDULE <br />GENERAL DOOR NOTES <br />LOCK FUNCTION <br />SPECIFICATION <br />1. NEW SWING DOORS TO BE LOCATED 4" OFF ADJACENT PARTITIONS TO ALLOW FOR DOOR TRIM, UNLESS NOTED OTHERWISE. <br />2. ALL DOORS AND DOOR HARDWARE TO COMPLY WITH ICC/ANSI: ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES ((CC A117.1-2009) <br />LOCKSET A <br />SCHLAGE ALX SERIES GRADE 2 CYLINDRICAL LOCK I LEVER STYLE: SPARTA <br />FUNCTION: ENTRANCE/OFFICE LOCK I FINISH: 606 SATIN BRASS (VERIFY) <br />CH 4: ACCESSIBLE ROUTES - SECTION 404 AND 2018 IBC SECTION 1010.1.9. <br />3. FIRE -RATED DOORS AND FRAMES SHALL COMPLY WITH 2O18 IBC SECTION 716. <br />LOCKSET B <br />EXTERIOR DOOR, VERIFY BUILDING STANDARD I LEVER STYLE: FINISH TO MATCH BUILDING STANDARD <br />FUNCTION: MATCH EXISTING LOCKSET j FINISH: TO MATCH BUILDING STANDARD (VERIFY) <br />4. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. ALL LOCKING <br />SCHLAGE ALX- SERIES- GRADE 2 CYLINDRICAL LOCK � LEVER- STYLE: SPARTA <br />PASSAGE <br />FUNCTION: PASSAGE LATCH I FINISH: 606 SATIN BRASS (VERIFY) <br />DOORS TO HAVE SINGLE-ACTION LEVER RELEASE / SELF -RELEASING DEAD BOLTS. <br />5. HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS, CABINETS, PLUMBING FIXTURES AND STORAGE <br />SCHLAGE ALX SERIES GRADE 2 CYLINDRICAL LOCK ( LEVER STYLE: SPARTA <br />PRIVACY <br />FUNCTION: PRIVACY LOCK' FINISH: 606 SATIN BRASS (VERIFY) <br />FACILITIES SHALL HAVE A LEVER OR OTHER SHAPE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE AND MICH DOES <br />NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE. <br />COMMERCIAL POCKET DOOR HARDWARE <br />POCKET <br />TRIMCO ADA POCKET DOOR PULL #1069 <br />6. DOOR THRESHOLD SHALL NOT EXCEED 1/2" IN HEIGHT. <br />FINISH: 606 SATIN BRASS <br />7. MAXIMUM DOOR OPENING PRESSURES ARE LIMITED TO 8.5 LBS AT EXTERIOR DOORS AND 5.0 LBS AT INTERIOR DOORS. <br />8. VERIFY ALL DOOR SWINGS, HARDWARE AND KEYING REQUIREMENTS. SUBMIT KEYING SCHEDULE AND HARDWARE SPECS FOR APPROVAL. <br />9. ACCESSIBLE RESTROOM SIGNAGE WITH TACTILE CHARACTERS TO BE LOCATED ON PUSH SIDE OF DOOR WITH CLOSER (UON) AND <br />WITHOUT HOLD -OPEN DEVICE. TACTILE CHARACTER SHALL BE INSTALLED 48" - 60" ABOVE FINISHED FLOOR PER CODE. RESTROOM <br />SIGNAGE SHALL COMPLY WITH IBC WA STATE AMENDMENTS, SECTION 1101.1.2.9 AND ICC/ANSI SECTION 703.6.3.E <br />10. MAIN EXTERIOR DOOR OR DOORS TO HAVE A READILY VISIBLE DURABLE SIGN POSTED ON THE EGRESS SIDE ON OR ADJACENT TO THE <br />DOOR STATING: "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1 INCH HIGH ON A <br />CONTRASTING BACKGROUND. <br />11. DOORS IN THE PATH OF EGRESS CAN NOT BE LOCKED FROM SIDE OF TRAVEL OF EMERGENCY EGRESS. <br />12. FOR ALL POCKET DOORS, INSTALL BUMPER (ON TRACK IN WALL) TO STOP DOOR BEFORE HANDLE HITS THE JAMB WHEN DOOR IS <br />RETRACTED. <br />ACCESSORY <br />SPECIFICATION <br />CLOSER <br />SARGENT: 1431 SERIES POWERGLIDE CLOSER (OR EQUAL) <br />PROVIDE STOP ARM ACCESSORY & HOLD OPEN FEATURE AS INDICATED ON DOOR SCHEDULE <br />13. ALL POCKET AND SLIDING DOORS TO HAVE A MINIMUM OF 32" OF CLEAR WIDTH. CLEAR WIDTH IS MEASURED BETWEEN THE SIDE EDGE <br />OF THE DOOR AND THE OPPOSITE STOP. <br />CONCEALED OVERHEAD STOP <br />GLYNN-JQHNSON: CONCEALED OVERHEAD DOOR STOP #100S (OR EQUAL) <br />FINISH: US32D SATIN STAINLESS STEEL <br />14. ALL GLAZING IN DOORS AND REUTES TO BE TEMPERED SAFETY GLASS PER CODE. <br />FLOOR STOP <br />BY GC <br />15. ALL NEW STAINED INTERIOR DOORS AND TRIM TO MATCH EXISTING WOOD SPECIES AND STAIN COLOR. <br />DOOR BOTTOM #1 <br />PEMKQ: FULL -MORTISE AUTOMATIC DOOR BOTTOM #411ARL (OR EQUAL) <br />SOUND SEAL <br />PEMKO: ADHESIVE -BACKED FIRE/SMOKE GASKETING #S88D (OR EQUAL), FINISH: DARK BROWN SILICONE <br />1. PROVIDE STANDARD WEIGHT COMMERCIAL DOOR HINGES. <br />2. ALL DOORS WITH CLOSERS TO HAVE BALL BEARING HINGES, ALL CLOSERS TO BE LOCATED ON INTERIOR OF SPECIFIED ROOM, U.O.N. <br />3. PROVIDE ALL NECESSARY ITEMS FOR DOORS, INCLUDING: BUTTS, LATCH & LOCKSETS, CLOSERS, DOOR STOPS & HOLDERS, KICKPLATES, <br />DOOR SILENCERS, THRESHOLDS, SMOKE GASKET AND WEATHER STRIPPING. SEE DOOR SCHEDULE "REMARKS/ACCESSORIES" COLUMN. <br />4. ALTERNATE MANUFACTURERS MAY BE SELECTED WITH DESIGNER'S APPROVAL <br />5. GC TO VERIFY THAT ALL (E) HARDWARE TO REMAIN IS IN GOOD WORKING ORDER, AND MEETS TENANT SPECIFIC REQUIREMENTS. <br />6. ALL DOOR HARDWARE TO COMPLY WITH ADA CODE REQUIREMENTS. <br />7. ALL FINISHES TO BE SATIN CHROME OR SATIN STAINLESS STEEL, U.O.N. <br />8. REFER TO FLOOR PLAN FOR DOOR HANDLING AND SWING. <br />GENERAL WINDOW NOTES <br />A. LOCATIONS OF SAFETY GLAZING: <br />OPENINGS WITH A VERTICAL EDGE WITHIN 24" OF A DOOR OPENING AND THE BOTTOM EDGE BELOW 60" A.F.F., AND; <br />OPENINGS MEETING ALL OF THE FOLLOWING: <br />1. BOTTOM EDGE LESS THAN 18" FROM FLOOR. <br />2. TOP EDGE GREATER THAN 36" ABOVE FLOOR, <br />3. GLASS AREA GREATER THAN 9 SQUARE FEET. <br />4. WALKING SURFACE WITHIN 36" OF THE GLASS UNIT. <br />OTHER LOCATIONS AS REQUIRED BY THE IBC, AS REQUIRED FOR STRENGTH, OR AS RECOMMENDED BY THE GLASS MFR. <br />SEE WINDOW TYPES FOR LOCATION OF TEMPERED SAFETY GLASS (SG). <br />WINDOW TYPES <br />SCALE: N.T.S. <br />c.� <br />w <br />cl- <br />CD <br />w <br />CD <br />z <br />w <br />U <br />0 <br />I <br />r'y <br />6'-0" <br />2 WAY MIRROR <br />(MIRROR ON WAITING SIDE <br />/f (SG) <br />FIN_ FLR. Alk <br />NOTE <br />IMAGING ROOM VIEWING WINDOW. <br />REFER TO FLOOR PLAN FOR LOCATION AND DETAIL 12/A9.1. <br />LEADED OR 1/2" TEMPERED SAFETY GLASS (SG) PER CODE. <br />TRIM AND FINISH: MATCH DOORS <br />TRIM TYPES <br />SCALE: N.T.S. <br />v v <br />SOLID WOOD TRIM HOLLOW METAL <br />(MATCH SUITE STANDARD) (GROUT SOLID) <br />DOOR TYPES <br />SCALE: N.T.S. <br />_PER SCHEDULE_ PER SCHEDULE_ <br />10448 <br />REGISTERED <br />ARCHITECT <br />F <br />JAMIE TRENDA <br />STATE OF WASHINGTON <br />rE <br />_ _ N <br />a O N E O N O N C ," L p 0 c- <br />° `w v <br />o ao 0 -6E Quo <br />m a0-0 °s ° ° _ <br />�� c N c o <br />c c <br />-0 ID <br />c <br />�� €� <br />O0) 0 N TO O O. O <br />E O O 0F ID <br />O D N O S A 7 <br />NC,J a. �,�Z ro <br />N m- � -o ya a J " 0- 0 <br />N �- O O v 0 <br />0 L» v o0E ENE O <br />"�. , ��ol <br />Q ALL O O O 0 N Ti i C'a i <br />0 <-i:< zov°'' ¢Eaa00oa <br />rmH <br />N Q O <br />U <br />U <br />l <br />2�aLo <br />Ca <br />C <br />U3 O Oop <br />mpp U a' <br />o <br />-U) <br />F. <br />r--+ <br />N -C c i <br />ca <br />2 u' <br />U <br />0) N:! <br />o 3:LL � <br />gm: <br />m a <br />Z <br />a <br />c o o <br />E <br />.a 7 <br />`taco <br />.. CV <br />o <br />co <br />0 <br />r N <br />a� <br />co z <br />o <br />art F- <br />0 <br />Y <br />W <br />H <br />r� <br />vi <br />W <br />d <br />i- <br />z <br />W <br />Qo <br />64 <br />H00 <br />� <br />w <br />aW <br />a <br />z <br />W I~- <br />0W <br />F-v-W <br />z <br />REVISIONS <br />NO. DATE BY <br />Al <br />a <br />0 <br />A <br />A <br />A <br />ISSUE DATES <br />DESIGN APPROVAL: <br />PERMIT SUBMITTAL: <br />PERMIT RECEIVED: <br />BID DOCS: <br />CONSTR. DOCS: <br />24"x36" SCALE: <br />AS NOTED <br />PLOT DATE: <br />01-20-2022 <br />CAD FILE: <br />21-176 A7.1 <br />JOB NUMBER: <br />21-176 <br />CHECKED: <br />DRAWN: <br />TP <br />STATUS: <br />PERMIT SET <br />SCHEDULES <br />A7m 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.