Laserfiche WebLink
Permit#: BW7 7-d06 <br />Site Address: 3101 RTH ST ` n <br />BUILDING CODE <br />2018 INTERNATIONAL BUILDING CODE <br />MAIN FLOOR LOAD <br />DEAD LOAD : 12 psf <br />LIVE LOAD: 40 psf <br />HABITABLE ATTIC LOAD <br />DEAD LOAD : 10 psf <br />LIVE LOAD: 30 psf <br />UNHABITABLE ATTIC WITH STORAGE LOAD <br />DEAD LOAD 10 psf <br />LIVE LOAD: 20 psf <br />UNHABITABLE ATTIC WITHOUT STORAGE LOAD <br />DEAD LOAD: 10 psf <br />LIVE LOAD: 10 psf <br />ROOF RAFTER, LOAD <br />DEAD LOAD: 15 psf <br />FLAT ROOF SNOW LOAD: 25 psf <br />SNOW EXPOSURE FACTOR (Ce): 1.1 <br />SNOW LOAD IMPORTANCE FACTOR (Is): 1.0 <br />THERMAL FACTOR (Ct): 1.1 <br />WIND DESIGN DATA <br />1. BASIC WIND SPEED: 110 MPH <br />2. WIND IMPORTANCE FACTOR (Iw): 1.0 <br />BUILDING CATEGORY: II <br />3. WIND EXPOSURE: B <br />4. Kzt = 1.38 <br />5, INTERNAL PRESSURE COEFFICIENT: NA <br />6. APPLICABLE WIND PRESSURE FOR <br />COMPONENTS AND CLADDING: NA <br />DORMER ROOF LOAD <br />DEAD LOAD: 10 psf <br />SNOW LOAD: 25 psf <br />SESIMIC DESIGN DATA <br />1. SEISMIC IMPORTANCE FACTOR: 1.0 <br />SEISMIC USE GROUP: 1 <br />2. SPECTRAL RESPONSE ACCELERATION (Ss): 118.2% G <br />3. SITE CLASS: D (ASSUMED) <br />4. SPECTRAL RESPONSE COEFFICIENTS (SDS): 94.6%G <br />5. SEISMIC DESIGN CATEGORY: D <br />6. BASIC SEISMIC -FORCE -RESISTING SYSTEM: SHEARWALLS <br />7. DESIGN BASE SHEAR: SEE CALCULATIONS <br />8. SEISMIC RESPONSE COEFFICIENT (Cs): 0.145 <br />9. RESPONSE MODIFICATION FACTOR (R): 6.5 <br />10. ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE PROCEDURE <br />SPECIAL INSPECTIONS <br />SPECIAL INSPECTIONS SHALL BE CONDUCTED IN ACCORDANCE WITH THE 2015 IBC, CHAPTER 17. <br />SPECIAL INSPECTION SHALL BE PROVIDED FOR: <br />- SEISMIC FORCE RESISTING SYSTEMS REQUIRING INSPECTION (IBC 1705.11) <br />- CON T. SPECIAL INSPECTION FOR POST INSTALLED ANCHORS <br />FOUNDATIONS <br />1. THE FOUNDATION DESIGN IS BASED ON THE RECOMMENDATION IN THE INTERNATIONAL <br />BUILDING CODE TABLE 1804.2. FOUNDATION WORK SHALL BE PERFORMED IN ACCORDANCE WITH <br />CHAPTER 18 OF THIS CODE. <br />2. THE FOUNDATION DESIGN IS BASED ON THE FOLLOWING VALUES: <br />ALLOW. SOIL BEARING = 1500 PSF <br />SOIL FRICTION = .40 <br />EQUIV. FLUID PRESSURES: <br />*ACTIVE PRESSURE = 35 PCF <br />PASSIVE PRESSURE = 200 PCF <br />3. ALL FOOTINGS SHALL BE FOUNDED AT LEAST 18 BELOW THE UNDISTURBED GROUND SURFACE <br />OR TO FROST DEPTH, ALL FOOTINGS SHALL BE FOUNDED ON COMPACTED FILL OR UNDISTURBED <br />NATURAL GRADE UNLESS OTHERWISE NOTED. <br />4. COMPACTION: MATERIAL FOR FILLING AND BACKFILLING SHALL CONSIST OF THE EXCAVATED <br />MATERIAL AND/OR IMPORTED BORROW AND SHALL BE FREE OF ORGANIC MATTER, TRASH, <br />LUMBER, OR OTHER DEBRIS. ALL WALLS SHALL BE ADEQUATELY BRACED PRIOR TO BACKFILLING. <br />FILL AND BACKFILL SHALL BE DEPOSITED IN LAYERS NOT TO EXCEED 8 INCHES THICK, <br />PROPERLY MOISTENED TO APPROXIMATE OPTIMUM REQUIREMENTS AND THOROUGHLY ROLLED OR <br />COMPACTED WITH APPROVED EQUIPMENT IN SUCH A MANNER AND EXTENT AS TO PRODUCE A <br />RELATIVE COMPACTION OF 90% OF MAXIMUM POSSIBLE DENSITY AS DETERMINED BY ASTM D1557, <br />HAND TAMPERS SHALL WEIGH AT LEAST 50 POUNDS EACH AND SHALL HAVE A FACE AREA NOT <br />IN EXCESS OF 64 SQUARE INCHES. HAND TAMPERS MAY BE OPERATED EITHER MANUALLY OR <br />MECHANICALLY AND SHALL BE USED WHERE LARGER POWER DRIVEN COMPACTION EQUIPMENT <br />CANNOT BE USED. FILL OVER 12" DEEP SHALL COMPLY WITH A GEO I ECHNICAL REPORT. <br />CONCRETE <br />1. ALL CONCRETE UNLESS OTHERWISE NOTED SHALL BE REGULAR WEIGHT HARD ROCK TYPE (150 <br />PCF) AGGREGATES SHALL CONFORM TO ASTM C33 WITH PROVEN SHRINKAGE CHARACTERISTICS <br />OF LESS THAN 0.05%. <br />2. CONCRETE COMPRESSIVE DESIGN STRENGTHS AT 28 DAYS (f'c) SHALL BE: <br />CONCRETE EXPOSURE & COMPRESSIVE DESIGN STRENGTHS <br />DESIGNATION <br />CONDITIONS <br />EXPOSURE <br />MIN. f'c (psi) <br />CLASS <br />HEATED: SLABS, BEAMS, GIRDERS, <br />INTERIOR CONC. & <br />COLUMNS, PIERS, AND BURRIED FOOTINGS <br />FOOTINGS <br />FO <br />2500 <br />FOUNDATION WALLS, UN -HEATED: SLABS, <br />FREEZING & THAWING <br />BEAMS, GIRDERS, COLUMNS, PIERS, PILE <br />CYCLES WITH LIMITED <br />F1 <br />3500 <br />CAPS, SHEAR WALLS <br />EXPOSURE TO WATER <br />3. ALL CONCRETE WITH A DESIGNATED COMPRESSIVE STRENGTH EXCEEDING 2500 PSI SHALL <br />REQUIRE SPECIAL INSPECTION BY AN INSPECTOR APPROVED BY THE BUILDING DEPARTMENT AND <br />THE ENGINEER. EXCEPTION: NO INSPECTION IS REQUIRED WHERE CONCRETE EXCEEDING 2500 PSI <br />IS DESIGNATED FOR WEATHERING PURPOSES ONLY. <br />4. CEMENT SHALL CONFORM TO ASTM C150, TYPE I, CSA NORMAL. <br />5. MAXIMUM SLUMP SHALL NOT EXCEED 4 INCHES IN FLATWORK. <br />6, PLACEMENT OF CONCRETE SHALL BE IN CONFORMANCE WITH ACI 301. <br />7. CONCRETE SHALL BE MAINTAINED IN A MOIST CONDITION FOR A MINIMUM OF FIVE (5) DAYS <br />AFTER PLACEMENT, ALTERNATE METHODS WILL BE APPROVED IF SATISFACTORY PERFORMANCE <br />CAN BE ASSURED, <br />8. KEYED CONSTRUCTION JOINTS SHALL BE USED IN ALL CASES. ALL CONSTRUCTION JOINTS <br />SHALL BE THOROUGHLY CLEANED AND ALL LAITANCE SHALL BE REMOVED. ALL VERTICAL JOINTS <br />SHALL BE THOROUGHLY WETTED AND SLUSHED WITH A COAT OF NEAT CEMENT IMMEDIATELY <br />BEFORE PLACING NEW CONCRETE. <br />9. SUBMIT LOCATION OF POUR JOINTS PRIOR TO PLACEMENT, POUR JOINTS SHALL BE LOCATED <br />TO MINIMIZE EFFECTS OF SHRINKAGE AS WELL AS PLACED AT POINTS OF LOW STRESS, MAXIMUM <br />AREA OF POUR JOINTS IS 400 SF. <br />10. MINIMUM CONCRETE COVERAGE OF REINFORCING STEEL FOR FORMED WORK SHALL BE AS <br />FOLLOWS: <br />EXPOSED TO EARTH OR WEATHER (#5 OR SMALLER): 11/" <br />EXPOSED TO EARTH OR WEATHER (#6 OR LARGER): 2" <br />*NOTE: CONCRETE CAST AGAINST GROUND SHALL HAVE 3" MINIMUM COVERAGE <br />11. PIPES OTHER THAN ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL <br />CONCRETE EXCEPT WHERE SPECIFICALLY APPROVED, <br />12. LEAN CONCRETE SHALL BE 2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE, <br />13. CONCRETE MIXES SHALL BE PROVIDED IN ACCORDANCE WITH ACI 318. <br />14. CONCRETE EXPOSED TO SULFATES, CONCRETE WITH LOW PERMEABILITY REQUIREMENTS, AND <br />CONCRETE WITH CHLORIDE ION CONTENT REQUIRE ADDITIONAL MIX DESIGN CONSIDERATIONS. IN <br />THE EVENT OF THESE REQUIREMENTS THE ENGINEER SHALL BE NOTIFIED BY THE CLIENT IN A <br />WRITING AND DESIGN MIXES SHALL BE PROVIDED PER ACI 318. <br />CEMENT CONTENT <br />F'c (PSI) <br />LBS/CUBIC YARD (MIN.) <br />SACKS PER CUBIC YARD <br />(MIN.) <br />NOTES <br />2500 <br />470 <br />5 <br />NOTE A <br />3500 <br />564 <br />6 <br />- <br />NOTE 1: MIXES SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. NO MORE <br />THAN A 1" PLUS TOLERANCE SHALL BE ALLOWED. <br />NOTE 2: AIR ENTRAINMENT IS REQUIRED FOR ALL CONCRETE EXPOSED TO WEATHER. FOR Y4" <br />AGGREGATE AN ENTRAINMENT OF 6% IS REQ'D. FOR Y2" AGGREGATE AN AIR ENTRAINMENT OF <br />7% IS REQ'D. <br />NOTE 3: POZZOLANS ARE NOT PERMITTED IN THE MIX DESIGN UNLESS APPROVED BY THE <br />ENGINEER. <br />A) WHERE SPECIAL INSPECTION IS NOT REQUIRED UNDER SECTION 1704.4 OF THE I.B.C., <br />CONCRETE SHALL HAVE A MINIMUM CEMENT CONTENT OF 5 SACKS PER CUBIC YARD OF <br />CONCRETE. <br />B) FOR STRENGTHS ABOVE 4000 PSI, PROPORTIONS SHALL BE ESTABLISHED BY THE METHODS <br />SPECIFIED ACI 318, <br />C) DESIGN MIX (OTHER THAN AS SPECIFIED IN THIS TABLE) SHALL BE SUBMITTED TO THE <br />BUILDING OFFICIAL TWO WEEKS PRIOR TO FIRST USE, <br />REINFORCING STEEL <br />1. ALL REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60 (fy = 60 KSI) FOR BAR <br />SIZES NO. 5 & LARGER, GRADE 40 (fy = 40 KSI) FOR NO. 3 AND NO. 4 BARS. <br />2. ALL REINFORCING STEEL SHALL BE LAPPED AS NOTED ON THE PLANS. WHERE LAP OR SPLICE <br />LOCATIONS ARE NOT SPECIFICALLY INDICATED ON THE CONSTRUCTION DOCUMENTS, LAPS AND/OR <br />SPLICES SHALL BE 42 BAR DIA AND BE WELL STAGGERED. <br />3. COMPLETE REINFORCING PLACEMENT DRAWINGS PREPARED IN ACCORDANCE WITH ACI 315 <br />SHALL BE REVIEWED BY THE ENGINEER AND AVAILABLE ON THE JOB SITE PRIOR TO THE <br />PLACING OF CONCRETE. <br />REINFORCING STEEL CONT. <br />4. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A82 AND A185 AND SHALL BE 6x6 <br />W2.1/W2.1 UNLESS OTHERWISE NOTED. LAP REINFORCEMENT 6" MINIMUM. <br />5. ANCHOR BOLTS, DOWELS AND OTHER EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE <br />BEFORE CONCRETE IS POURED. SLAB ON GRADE REINFORCEMENT SHALL BE PLACED AT <br />MID -DEPTH OF SLAB AND SHALL BE HELD SECURELY IN PLACE WITH MECHANICAL DEVICES <br />DURING PLACING OF THE CONCRETE, <br />6. REINFORCEMENT SHALL PLACED CONTINUOUS AROUND CORNERS AND INTERSECTIONS UNLESS <br />SPECIFIED OTHERWISE. <br />FRAMING LUMBER <br />1. FRAMING LUMBER SHALL BE DOUGLAS FIR/LARCH NO.1 FOR POSTS, BEAMS, AND HEADERS; <br />HEM -FIR N0.2 FOR 2X AND 3X JOISTS, AND STUDS; AND HEM -FIR NO.2 FOR ALL TOP AND <br />BOTTOM PLATES (GRADES ARE TYPICAL UNLESS OTHERWISE NOTED ON PLANS). LUMBER TO BE <br />GRADE MARKED PER WCLIB ';SPECIFICATIONS. <br />2. STRUCTURAL SHEATHING SHALL BE APA RATED PLYWOOD, EXPOSURE I SHEATHING <br />CONFORMING TO EITHER COMMERCIAL STANDARDS DOC PS 1 OR PS 2. PROVIDE MINIMUM OF <br />3/8" EDGE DISTANCE ON ALL NAILS AND A 1 /8" EXPANSION JOINT BETWEEN ALL PANEL EDGES. <br />MINIMUM SHEATHING REQUIREMENTS ARE AS FOLLOWS: <br />ROOF SHEATHING TO BE 15/32" C-D INT-APA RATED PLYWOOD WITH EXTERIOR GLUE, P.I. <br />24/16 (USE 5-PLY FOR PANELIZED ROOFS). NAIL WITH 8d NAILS AT 6" ON CENTER AT <br />PANEL EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED <br />OTHERWISE. <br />SUB FLOORING TO BE 3/4 T&G C-D INT-APA RATED PLYWOOD WITH EXTERIOR GLUE, P.I. <br />48/24. GLUE AND NAIL WITH 10d NAILS AT 6 ON CENTER AT PANEL EDGES AND 12" ON <br />CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE. <br />3. NAILING SHALL CONFORM TO TABLE 2304.10.1 OF THE INTERNATIONAL BUILDING CODE UNLESS <br />NOTED OTHERWISE, USE COMMON NAILS THROUGHOUT UNLESS NOTED OTHERWISE. <br />4. NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY DETAILED OR <br />APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. <br />5. USE DOUBLE JOISTS UNDER WALLS OR PARTITIONS PARALLEL TO JOISTS UNLESS SPECIFICALLY <br />NOTED OTHERWISE. USE SOLID BLOCKING UNDER PARTITIONS PERPENDICULAR TO JOISTS. <br />6. RIM JOIST ARE 1%" LSL OR 2x SOLID SAWN LUMBER AS MINIMUM. <br />7. MAXIMUM MOISTURE CONTENT SHALL NOT EXCEED 16% FOR ALL STRUCTURAL MEMBERS, <br />8. PROVIDE 2X2 WASHERS UNDER HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING <br />ON WOOD. <br />9. BOLT HOLES SHALL BE NOMINAL DIAMETER OF BOLT PLUS 1/16" UNLESS OTHERWISE NOTED, <br />LAG BOLT PILOT HOLES SHALL BE PRE -DRILLED TO 60% OF THE NOMINAL DIAMETER OF THE LAG <br />BOLT UNLESS OTHERWISE NOTED. <br />10. ALL SILL PLATES SHALL BE BOLTED TO THE FOUNDATION WITH 5/8" MINIMUM DIAMETER <br />BOLTS SPACED AT 48" O.C. MAXIMUM SPACING (EMBED 7 MINIMUM INTO CONCRETE OR <br />MASONRY). SEE PLANS AND DETAILS FOR SPECIFIC REQUIREMENTS WHERE OCCUR. <br />11. ALL FRAMING LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE <br />TREATED. (SEE NOTE 1 FOR MINIMUM GRADE INFORMATION), ALL FOUNDATION BOLTS AND <br />CONNECTORS MUST BE HEAVY GALVANIZEDED, OR Z-MAX COATING TO PROTECT FROM <br />OXIDATION, <br />12, FIELD -CUT ENDS, NOTCHES, AND DRILLED HOLES OF PRESSURE PRESERVATIVELY TREATED <br />WOOD SHALL BE RETREATED IN THE FIELD IN ACCORDANCE WITH AWPA M4. IRC R317.1.1. <br />13. 2X4 RAFTERS EXCEPT WHERE SPECIFICALLY DETAILED SHALL NOT SUPPORT SUSPENDED <br />CEILINGS, SPRINKLERS, DROP SOFFITS, OR ANY OTHER ELEMENTS. <br />14. WIRE STAPLES MAY BE SUBSTITUTED FOR DIAPHRAGM AND SHEARWALL NAILING WHEN <br />APPROVED BY THE STRUCTURAL ENGINEER. <br />15. EXTERIOR STUD WALLS SHALL BE 2X6 @ 16" O.C.. UNLESS NOTED OTHERWISE. INTERIOR <br />STUD BEARING WALLS SHALL BE CONSTRUCTED USING 2X4 @ 16" O.C. AT UPPER TWO FLOORS <br />AND EITHER 2X6 @ 16" O.C. OR 3X4 @ 16" O.C. BELOW TOP TWO FLOORS. STUD NONBEARING <br />WALLS SHALL BE CONSTRUCTED USING 2X4 @ 24" O.C.. UNLESS NOTED OTHERWISE. SEE NOTE <br />1 FOR LUMBER GRADES OF STUDS AND PLATES. <br />16. FRAMING ANCHORS FOR JOISTS, PURLINS AND POSTS SHALL BE SIMPSON, OR APPROVED <br />EQUAL. APPROVAL MUST BE OBTAINED IN WRITING PRIOR TO INSTALLATION. FILL ALL FASTENER <br />HOLES WITH FASTENER TYPES (NAILS, BOLTS, ETC.), _SIZES, AND QUANTITIES AS SPECIFIED BY <br />THE MANUFACTURER. <br />17. ALL HEADERS SHALL BE 4X8 DF#2 UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />18. OSB OF EQUAL OR GREATER THICKNESS MAY BE SUBSTITUTED FOR PLYWOOD USED IN <br />SHEAR PANELS. <br />19. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE DETAILS AND NOTES. <br />GLUED -LAMINATED TIMBER <br />1. ADHESIVE SHALL BE FOR WET USE. <br />2. LAMINATIONS SHALL BE OF DOUGLAS FIR/WESTER LARCH, COMBINATION 24F-V4 FOR <br />SPAN BEAMS AND 24F-V8 FOR CONTINUOUS MULTIPLE SPAN AND CANTILEVERED BEAM`, <br />FABRICATED IN ACCORDANCE WITH AITC A190.1 AND ASTM D 3737. Re\ <br />V <br />3. FABRICATION SHALL BE BY A LICENSED FABRICATOR; SHOP DRAWINGS SHALL BE SUE A <br />TO THE ENGINEER FOR APPROVAL PRIOR TO FABRICATION. AITC CERTIFICATES OF INSPLu l lulN <br />ARE REQUIRED FOR ALL MEMBERS. <br />4. GLULAM BEAMS EXPOSED TO WEATHER SHALL BE WOLMANIZED OR PRESSURE TREATED. <br />STRUCTURAL STEEL <br />1. ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO ASTM A36 AND SHALL BE <br />FABRICATED AND ERECTED IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR STRUCTURAL <br />STEEL BUILDINGS", LATEST EDITION. SHOP DRAWINGS SHALL BE SUBMITTED FOR APPROVAL <br />PRIOR TO FABRICATION. <br />2. C-CHANNELS SHALL CONFORM TO ASTM A36 (Fy=36 ksi) UNLESS OTHERWISE NOTED ON <br />PLANS. <br />3. BOLTS SHALL CONFORM TO ASTM A307 UNLESS OTHERWISE NOTED. BOLTS INDICATED AS HIGH <br />STRENGTH SHALL CONFORM TO ASTM A325. <br />4. NO ATTEMPT HAS BEEN MADE TO DIFFERENTIATE BETWEEN SHOP AND FIELD WELDED <br />CONNECTIONS. ALL WELDING IS TO COMPLY WITH AWS SPECIFICATIONS AND IS TO BE DONE BY <br />THE WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (WABO) CERTIFIED WELDERS. ALL WELDING <br />IS TO BE DONE BY ELECTRIC ARC PROCESS AND SHALL BE PERFORMED WITH APPROVED E70 <br />ELECTRODES AS REQUIRED BY THE BUILDING CODE. <br />5. SPECIAL INSPECTION IS REQUIRED FOR ALL FIELD WELDS. <br />6. ARCHITECTURAL PLANS ARE PART OF THE STRUCTURAL DESIGN DRAWINGS AND ARE TO BE <br />USED TO DEFINE DETAIL CONFIGURATIONS INCLUDING, BUT NOT LIMITED TO, RELATIVE LOCATIONS <br />AND ELEVATIONS OF ALL MEMBERS, ELEVATIONS LOCATION OF ALL OPENINGS, ETC. THE <br />ARCHITECTURAL PLANS MUST BE USED IN THE DEVELOPMENT OF SHOP DRAWINGS, <br />7, REFER TO ARCHITECTURAL DRAWINGS FOR MISCELLANEOUS STEEL SHOWN OR NOTED ON THE <br />DRAWINGS AS TO LOCATION FOR WHICH THE EXTENT IS NOT CLEAR. <br />8. UNLESS A LARGER SIZE OF FILLET WELD IS SPECIFIED ON THE PLANS, PROVIDE MINIMUM SIZE <br />OF WELD PER AISC SPECIFICATION AND TABLE J2.4. <br />9. ALL STRUCTURAL STEEL, HARDWARE, AND MISC. STEEL EXPOSED TO EARTH OR WEATHER <br />SHALL BE HOT DIPPED GALVANIZED PER ASTM A123 UNLESS OTHERWISE NOTED, DAMAGED <br />GALVANIZED COATINGS AND STEEL DESIGATED FOR ZINC PRIMING SHALL BE PROTECTED WITH A <br />ZINC RICH PRIMER AND TOP COAT PER SSPC-PS SPECIFICATIONS. STEEL SHALL BE CLEANED <br />PRIOR TO PRIMING. THE PRIMER SHALL BE CLASSIFIED AS INORGANIC WITH A 92-95% METALLIC <br />ZINC IN DRY FILM. THE PRIMER SHALL BE APPLIED IN A CONTROLLED DRY ENVIRONMENT AND <br />MAY CONSIST OF BRUSH OR SRAY COATING WITH A DRY FLIM THICKNESS BETWEEN 2.5-3.5 <br />MILS. AN OUTER PROTECTIVE PAINT LAYER SHALL BE APPLIED OVER THE PRIMER. THE PRIMER <br />AND TOP COAT(S) SHALL BE FULLY CURED PRIOR TO ERRECTION. THE OUTER COATING SHALL BE <br />INSPECTED UPON ERRECTION ON -SITE. ANY DAMAGE TO THE ZINC -RICH PAINT PRIMER SHALL BE <br />SPOT COVERED ON -SITE. <br />10. PROVIDE SHOP DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />11. IF THE STEEL FABRICATOR'S SHOP DRAWINGS DIFFER FROM THE DESIGN DRAWINGS APPROVED <br />BY THE BUILDING OFFICIAL, REDESIGN DRAWINGS BEARING THE SEAL AND SIGNATURE OF THE <br />PROJECT STRUCTURAL ENGINEER SHALL BE SUBMITTED ALONG WITH THE SHOP DRAWINGS TO <br />BUILDING OFFICIAL FOR APPROVAL. <br />GENERAL <br />1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CONTRACT DRAWINGS. <br />2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE <br />SAFETY OF THE BUILDING. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, BRACING AND <br />GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. ANY <br />DEVIATION MUST BE APPROVED PRIOR TO ERECTION. <br />3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. ANY DEVIATION MUST <br />BE APPROVED BY OSHA PRIOR TO ERECTION. <br />4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION PROCEDURES <br />INCLUDING LAGGING, SHORING AND PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS <br />AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. <br />5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES <br />AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION <br />OF THE ENGINEER AND BE RESOLVED BEFORE PROCEEDING WITH THE WORK. <br />6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS <br />ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR <br />DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO REVIEW BY THE ENGINEER. <br />7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN ADDITION TO ANY <br />OTHER SPECIFIC DETAIL CALLED OUT, <br />8. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SIZE AND <br />LOCATION OF ALL OPENINGS REQUIRED FOR DUCTS, PIPES, PIPE SLEEVES, ELECTRICAL CONDUITS, <br />AND OTHER ITEMS TO BE EMBEDDED IN CONCRETE OR OTHERWISE INCORPORATED IN <br />STRUCTURAL WORK. <br />9. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER STANDARD DETAILS FOR HEATERS, <br />MECHANICAL EQUIPMENT, VENTS, DUCTS, PIPING, ETC, ALL SUSPENDED MECHANICAL EQUIPMENT <br />SHALL BE SWAY OR LATERALLY BRACED. <br />10. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS <br />THE BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL <br />CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE ENGINEER SO <br />THAT THE PROPER REVISIONS MAY BE MADE. MODIFICATION TO DETAILS OF CONSTRUCTION <br />SHALL NOT BE MADE WITHOUT PRIOR WRITTEN APPROVAL OF THE ENGINEER. <br />11. ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED A PART OF THE STRUCTURAL <br />DESIGN DRAWINGS AND ARE TO BE USED TO DEFINE DETAIL CONFIGURATIONS INCLUDING; BUT <br />NOT LIMITED TO RELATIVE LOCATION OF MEMBERS, ELEVATIONS, DIMENSIONS AND LOCATIONS OF <br />ALL OPENINGS, ETC. <br />FORES DILL LLC <br />[TeriNarnej <br />7/2 /2020 <br />RESIDENTIAL ALTERATIONS <br />REPAIR DORMER ADDN IN ATTIC BY PRIOR <br />OWNER e BACKYARD SITED <br />Date: ®. <br />.�� <br />fob Site Set Fire/Planning Set <br /><,9 <br />O <br />Ln <br />Ln <br />C\I <br />Lu <br />n <br />L <br />® <br />U <br />Q <br />Lu <br />L6 <br />C\I <br />z <br />O <br />ctI <br />T) c�I <br />cv <br />o <br />o <br />c�I <br />Lu <br />� <br />O <br />O <br />o <br />® <br />0! <br />uJ w <br />Lu <br />UA <br />® <br />L <br />> <br />O <br />cv <br />M <br />U Ul JU ? 3 <br />2022 <br />uy <br />CITY 0 EVERETT <br />Perrnit Service'. <br />CLI <br />7� � zr <br />k k Jim 9 <br />5/13/2022 <br />Drawn By: J115 <br />Checked By: CCC <br />*ate: •1-2022 <br />