My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3101 8TH ST 2020 Plans 2022-12-15
>
Address Records
>
8TH ST
>
3101
>
Plans
>
3101 8TH ST 2020 Plans 2022-12-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2022 4:30:57 PM
Creation date
12/15/2022 4:17:19 PM
Metadata
Fields
Template:
Address Document
Street Name
8TH ST
Street Number
3101
Permit
BW2007-006
Year
2020
Notes
SFR REMODEL TO REMEDIATE WORK WITHOUT PERMITS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />CONTRACTOR SHALL VERIFY ALL NOTES, DIME <br />CONDITIONS PRIOR TO CONSTRUCTION_ <br />ALL 5EAi`15 4 HEADERS TO BE 4x10 DF2, U.N.O <br />PROVIDE SOLID 5LOCKNG OVER SUPPORTS. <br />PROVIDE FIRE 5LOCKINCa o ALL. PLUM5ING PE <br />WINDOW $ DOORS ARE SHOWN $ NOTED AS NO <br />WINDOW d-IEADERS a 6'-10" ABOVE SUB -FLOOR, U.N.O. <br />(%), (N) OR SIM. INDICATES NUMBER OF 2x STUDS OR POST REQUIREf;) <br />POINT LOAD <br />ALL WOOD IN CONTACT WITH CON(_ TO BE PRESSURE TREATED. <br />SMOKE DETECTORS: * SHALL BE 110 V INTERCONNECTED W/ 5ATTERY <br />5ACKUP * SMALL BE INSTALLED ON EACH FLOOR AND IN ALL BEDROOMS <br />AND SHALL 5E INSTALLED IN EACH LOCATION WHERE THERE IS A CEILING <br />CHANGE GREATER THAN 24" <br />BATTERY OPERATED SMOKE DETECTORS ARE ACCEPTABLE WHERE <br />REQUIRED IN FINISHED CONDITIONS SPACE <br />FIRE5LOCKING IN ACCORDANCE W/ <br />SECTION R602.8, IRC, <br />LIMIT SHOWER FLOW TO 2.5 G.P.M. <br />WALLS SHALL BE WATERPROOF TO A <br />MIN. 10" ABOVE DRAIN INLET. <br />ALL GLAZING INCLUDING WINDOWS WITHIN <br />60" OF STANDING/WALKING SURFACE <br />SHALL BE SAFETY GLASS. <br />FIRE BLOCMING & DRAFT STOPPING <br />FIRE 15LOCKING PER I5C SEC. 1112.1,11i.21,1406.2A <br />DRAFT STOPPING PER 15C 1114 4 ilia <br />Entry <br />*NCC <br />------------------- <br />Kitchenette <br />*NCC <br />ABANDON EXISTING <br />;ITCHENETTE IN ITS <br />ENTIRETY <br />X. 5RG POST <br />MAIN, TYP <br />Furna <br />I <br />1 <br />Hot Water <br />_f <br />t <br />Closet <br />— WINDOW WELL <br />COPYdght2021 <br />DEFINITIVE DESIGN GROUP <br />THESE DRAWINGS ARE COPYRIGHTED MATERIAL <br />AND MAY NOT BE COPIED OR REDRAWN WITHOUT <br />THE EXPRESSED WRITTEN CONSENT OF DEFINITIVE <br />DESIGN GROUP, THESE DRAWINGS ARE LIMITED TO <br />ASPECIFIC PROJECT FOR PERSONS NAMED HEREIN <br />AND FOR THE CONSTRUCTION OF ONE BUILDING. <br />ANY OTHER USE OR REUSE IS STRICTLY <br />PROHIEITED WITHOUT WRITTEN CONSENT FROM <br />DEFINITIVE DESIGN GROUP. <br />INDICATES BRIG <br />FROM ADOVE <br />IGAS FURNACE SHALL <br />HEAT ENTIRE DWELLING/ <br />° INSTALLED UNDER 11 <br />PERMIT N <br />It � <br />PT LOAD <br />ROOF A 0 <br />1 <br />t *NCC <br />I CEILING HEIGHT IS <br />NOT CODE COMPLIANT <br />FOR HUMAN OCCUPANCY <br />t <br />FOR WALLS SHOWN THUSLY ®®®®®® <br />VERIFY NEW/UNPERMITTED ELECTRICAL <br />AND REMOVE PORTION OF SHEET ROCK <br />FOR ELECTRICAL INSPECTION <br />FOR WALLS SHOWN THUSLY <br />VERIFY NEW/UNPERMITTED ELECTRICAL. <br />AND REMOVE PORTION OF SHEET ROCK <br />FOR ELECTRICAL INSPECTION <br />SERVICE PANEL UPGRADE <br />O <br />INSTALLATION OF GAS WATER HEATER <br />-DATE 8/26/2018 <br />-DATE UNKNOWN <br />-PERMIT NO. E1 06-151 <br />-PERMIT NO. M1512-030 <br />®CONTRACTOR ® <br />-CONTRACTOR UNKNOWN <br />BRIGHT 4 RIGHT ELECTRICAL SERVICES <br />VARIOUS LIGHT AND RECEPTICLE <br />REPLACEMENT IN BASEMENT <br />BATHROOM INSTALL <br />®GFCI OUTLETS INSTALLED <br />-EXTENT OF PLUM51NG 4 ELECTRICAL UNKNOWN <br />DATE UNKNOWN <br />-NO ROUGH -IN PLUMING ALTERATION <br />®PERMIT UNKNOWN <br />DATE OF CONSTRUCTION UNKNOWN <br />®CONTRACTOR INSTALLED YES <br />-PERMIT UNKNOWN <br />®CONTRACTOR UNKNOWN <br />®CONTRACTOR INSTALLED YES <br />CONTRACTOR UNKNOWN <br />O <br />ABANDON 220v CIRCUIT THAT <br />SERVICES THE OVEN/RANGE ON THE <br />INSTALLATION OF GAS FURNACE <br />UPPER FLOOR (ATTIC FLOOR) PER <br />DATE UNKNOWN <br />INSPECTOR'S RECOMMENDATION <br />-PERMIT UNKNOWN <br />-CONTRACTOR INSTALLED YES <br />®CONTRACTOR UNKNOWN <br />�v�i.�4tcLr�.aiy� �' I !^r�✓'!2� <br />22922 141h Place UJ&s t <br />coil-wll, l/Jdol-mng'ton 9eo21 <br />Note: <br />All non -permitted electrical work dome to <br />date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permit approval by any & all <br />governing agencies, or mast be removed, <br />in its entirety. <br />All non -permitted mechanical work dome <br />to date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permitted approval by any & all <br />governing agencies. See drawings for <br />specific items to be inspected and <br />permitted. <br />All non -permitted plumbing work donne <br />to date shall be exposed for inspection, <br />under the Inspector's direction, for <br />proper permit approval by any & all <br />governing agencies. <br />Any subsequent work rewired, with all <br />disciplines shown above, shall be <br />completed by a licensed contractor in <br />that specific discipline. <br />CITY OF EVERETT BASEMEN"Ir <br />Case # CE20-0376 <br />Project AdTess <br />3101 8th Street PLAN <br />Everett CIA 98201 <br />Date AprII 8th, 2021 <br />Drawn Bu: JMP <br />701LA2.t <br />612_300000300 <br />'arcel <br />
The URL can be used to link to this page
Your browser does not support the video tag.