STRUCTURAL NOTES <br />(THESE NOTES ARE TYPICAL UNLESS NOTED OR DETAILED OTHERWISE ON DRAWINGS) CONCRETE <br />CODE ALL CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED, AND PLACED IN ACCORDANCE WITH CHAPTER 26 OF MAILS, BOLTS, AND METAL CONNECTORS FOR WOOD <br />ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, ACI (ACI 18 AND THE AMERICAN CONCRETE INSTITUTE°S SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS ALL NAILS SHALL CONFORM TO THE STANDARDS SET FORTH BY THE NATIONAL DESIGN STANDARDS (NDS) FOR <br />SPECIFICATIONS, AND THE INTERNATIONAL BUILDING CODE (IBC), 2018 EDITION. SPECIFICATIONS AND STANDARDS WOOD CONSTRUCTION, LATEST EDITION. NAILING NOT SPECIFIED SHALL BE PER BBC TABLE 2304.10.1 NAILING <br />WHERE REFERENCED ON THE DRAWINGS ARE TO BE THE LATEST EDITION. ALL CONCRETE SHALL BE STONE -AGGREGATE CONCRETE HAVING A UNIT WEIGHT OF APPROXIMATELY 150 POUNDS SCHEDULE, ALL NAILS CALLED OUT ON PLANS SHALL BE COMMON NAILS UNLESS NOTED OTHERWISE AND SHALL <br />PER CUBIC FOOT. MEET OR EXCEED THE FOLLOWING MINIMUM GUIDELINES: <br />DESIGN LOADS <br />NAIL SHANK 0 MIN LENGTH <br />DEAD LOADS: CONCRETE STRENGTHS AT 28 DAYS (fc) AND MIX CRITERIA SHALL BE AS FOLLOWS: <br />F_;d COMMON 01310 2 1/2°° SHANK <br />ROOF 12 PSF <br />- <br />villmu <br />-._ ---------._ <br />--- <br />FLOOR 12 PSF <br />TYPE OF CONSTRUCTION <br />f°c* <br />MAXIMUM <br />IN CEMENT <br />MAXIMUM <br />10d COMMON <br />0.148 3" SHANK <br />COLUMNS <br />------�_ <br />-_--- �_ <br />STRUCTURAL STEEL <br />-- - <br />WATER/CEMENT <br />CONTENT PER CUBIC <br />SHRINKAGE STRAIN <br />LIVE LOADS: <br />RATIO <br />YARD <br />12d COMMON <br />0.1480 3 1/4" SHANK <br />- -- <br />- <br />--' <br />ROOF (SNOW LOAD) 25 PSF <br />RESIDENTIAL (DECK) 60 PSF <br />SLABS ON GRADE <br />3000 PSI <br />0.55 <br />5 1/2 SACK <br />N/A <br />16d COMMON <br />0.162 3 1/2" SHANK <br />COLUMN BEARING <br />ON BEAM <br />RATED SHEATHING <br />FOOTINGS <br />3000 PSI <br />0.55 <br />5 1/2 SACK <br />N/A <br />10d BOX NAILS MAY BE SUBSTITUTED FOR 8d COMMON NAILS WITH NO CHANGE IN NAIL SPACING. FRAMING <br />-- -- <br />--- <br />(LIVE LOADS ARE REDUCED WHERE PERMISSIBLE PER IBC SECTION 1607.11). <br />MEMBERS MAY BE NAILED WITH 16d SINKERS (0.148�o x 3 1/4°o <br />), BUT ONLY 16d COMMON NAILS SHALL BE USED <br />BEAM NTINU <br />COOUS <br />! <br />SHEAR WALL <br />SWX <br />THE MINIMUM AMOUNT OF CEMENT LISTED ABOVE MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS <br />WHERE 16d NAILS ARE INDICATED IN THIS DRAWING SET. ENGINEER MAY APPROVE OTHER NAILS IF NAIL LABELS <br />OVER SUPPORT <br />(SEE SCHEDULE) <br />EARTHQUAKE <br />SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING <br />ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE <br />ARE SUBMITTED TO ENGINEER PRIOR TO START OF CONSTRUCTION. <br />- ----� <br />CONCRETE WALL <br />COLUMN MARK <br />EQUIVALENT <br />(SEE SCHEDULE) <br />LATERAL FORCE PROCEDURE PER ASCE 7-16 SECTION 12.8. <br />AGGREGATE, WATER, AND ADMIXTURES AS WELL AS THE WATER -CEMENT RATIO, SLUMP, CONCRETE YIELD, AND <br />ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307, PROVIDE WASHERS UNDER THE HEADS AND NUTS <br />SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH CHAPTER 26 OF ACI 318. <br />OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. LEAD HOLES FOR LAG BOLTS SHALL BE BORED FOR THE <br />BEARING STUD <br />(�C <br />FOOTING MARK---�___.�_ <br />SITE CLASS (ASSUMED) D <br />SHANK AND THREADED PORTIONS PER NDS 12.1.4.2. <br />WALL <br />(SEE SCHEDULE) <br />SHORT PERIOD SPECTRAL RESPONSE ACCEL (SS) 1.365 <br />ALL CONCRETE EXPOSED TO WEATHER OR TO FREEZING TEMPERATURES SHALL BE AIR -ENTRAINED IN ACCORDANCE <br />_ _-r__ ----- <br />____.---___--- <br />-- _ <br />-------- <br />ONE SECOND SPECTRAL RESPONSE ACCEL (51) 0.484 <br />WITH ACI 318 TABLE 19.3.3.1 FOR MODERATE EXPOSURE CLASS F1. <br />CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, CATALOG <br />NON -BEARING <br />HOLDOWN MARK <br />j <br />SHORT PERIOD DESIGN SPECTRAL RESPONSE ACCEL (SDS) 0,910 <br />TO BE THE LATEST EDITION, OR ENGINEER APPROVED EQUAL. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE <br />STUD WALL-- <br />- r d <br />(SEE SCHEDULE) <br />i- <br />ONE SECOND DESIGN SPECTRAL RESPONSE ACCEL (SDI) 0.586 <br />*PROVIDE fc SPECIFIED IN TABLE FOR DURABILITY REQUIREMENTS. 2500 PSI CONCRETE MEETS STRENGTH <br />WITH THE MANUFACTURER'S RECOMMENDATIONS AND WITH THE NUMBER AND SIZE OF FASTENERS AS SPECIFIED <br />BEARING STUD <br />— <br />HANGER MARK <br />- <br />RISK CATEGORY 11 <br />REQUIREMENTS, THEREFORE SPECIAL INSPECTION IS NOT REQUIRED. <br />BY THE MANUFACTURER. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS, <br />SHEAR WALL <br />(SEE SCHEDULE) <br />SEISMIC IMPORTANCE FACTOR (IE) 1.0 <br />SCREWS, OR BOLTS IN EACH MEMBER.-- <br />--- <br />- <br />-- <br />SEISMIC DESIGN CATEGORY D <br />REINFORCING STEEL <br />NON -BEARING <br />FLAG NOTE <br />BASIC SEISMIC FORCE -RESISTING -SYSTEM CANTILEVERED STEEL COLUMNS <br />INSTALL SOLID BLOCKING AT ALL BEARING POINTS. ALL SHIMS SHALL BE SEASONED, DRIED, AND THE SAME GRADE <br />STUD SHEAR WALL <br />(SEE PLAN NOTES) <br />j <br />RESPONSE MODIFICATION FACTOR, (R) 1.25 <br />REINFORCING STEEL SHALL BE DEFORMED BILLET STEEL CONFORMING TO ASTM A615, AND SHALL BE GRADE 60 (Fy <br />(MINIMUM) AS MEMBERS CONNECTED. <br />STEEL MOMENT <br />REDUNDANCY FACTOR (p) 1.0 <br />® 60,000 PSI), UNLESS NOTED OTHERWISE. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED <br />CMU WALL <br />FRAME CONK. <br />SEISMIC RESPONSE COEFFICIENT (CS) 0,728 <br />SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615 MAY BE WELDED IF MATERIAL <br />GALVANIZATION <br />W = TOTAL SEISMIC DEAD LOAD AS DEFINED PER ASCE 7-16 SECTION 12.7.2. <br />PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D1.4 ARE <br />SUBMITTED. <br />UNLESS NOTED OTHERWISE, STEEL CONNECTORS IN CONTACT WITH TREATED WOOD SHALL BE GALVANIZED <br />ACCORDING TO THE FOLLOWING TABLE: <br />ABBREVIATIONS <br />BASE SHEAR (V), V ® CSW = RD j W <br />REINFORCING STEEL SHALL BE DETAILED INCLUDING HOOKS AND BENDS IN ACCORDANCE WITH ACI SP-66 AND ACI <br />(A) ABOVE <br />UNTREATED <br />ACQ�C <br />CBApA OTkIER <br />OTHER PT <br />GLB <br />CLUE <br />-LAMINATED BEAM <br />318, LATEST EDITIONS. UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS <br />GALVANIZATION <br />CCA-C <br />SBX <br />ACQ-D <br />AC A <br />------- <br />----- <br />---- -- -� <br />_ <br />WIND LOADS: <br />SHALL BE PER SCHEDULE. <br />WOOD <br />CA-B BORATE <br />WOOD <br />AB <br />ANCHOR <br />BOLT <br />HORIZ <br />HORIZONTAL <br />----- --- <br />BASIC WIND SPEED (3 SECOND GUST) 98 MPH <br />MECHANICAL SPLICING OF REINFORCING BARS, WHERE INDICATED ON THE DRAWINGS, SHALL BE BY AN ICBO <br />G90 <br />X <br />X <br />X <br />ALT <br />ALTERNATE <br />! KP <br />KING <br />POST <br />EXPOSURE B <br />APPROVED SYSTEM, SHALL DEVELOP 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR, AND SHALL BE <br />G1$5 <br />X <br />X <br />X <br />X <br />X X <br />ARCH <br />ARCHITECT <br />KSI <br />KIPS <br />PER SQUARE INCH- <br />KZT 1.0 <br />INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. <br />HDG <br />X <br />X <br />X <br />X <br />X X <br />(B) <br />BELOW <br />-.-- <br />; L <br />ANGLE <br />-- <br />SEE PLANS FOR ADDITIONAL DESIGN LOADS. <br />REINFORCING SHALL BE PLACED AND ADEQUATELY SUPPORTED PRIOR TO PLACING CONCRETE. WET -SETTING <br />STT300 <br />X <br />X <br />X <br />X <br />X X <br />X <br />X <br />BD <br />BAR DIAMETER <br />MECH <br />MECHANICAL <br />STATEMENT' OF SPECIAL INSPECTIONS <br />EMBEDDED ITEMS IS NOT ALLOWED WITHOUT PRIOR ENGINEER APPROVAL. BARS PARTIALLY EMBEDDED IN <br />G90 = 0.90 OZ. OF ZINC PER SQUARE FOOT OF AREA <br />BLKG <br />BLOCKING <br />MF <br />MOMENT <br />FRAME <br />HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR APPROVED BY THE STRUCTURAL <br />G185 = 1.85 OZ. OF ZINC PER SQUARE FOOT OF AREA <br />--- -- <br />SPECIAL INSPECTIONS ARE REQUIRED AS INDICATED IN THE FOLLOWING TABLE. THE CONTRACTOR SHALL SUBMIT A <br />ENGINEER, REFER TO CHAPTER 25 OF ACI 318 FOR OTHER REINFORCING STEEL REQUIREMENTS. <br />HDG m HOT DIP GALVANIZED <br />BM <br />BEAM <br />MTL <br />�. <br />METAL <br />WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND OWNER PRIOR TO COMMENCEMENT OF <br />MINIMUM LAPS AND EMBEDMENT <br />SST300 =TYPE 316E STAINLESS STEEL <br />BOT - <br />BOTTOM <br />— '--m ~ <br />-_J <br />NS <br />NEAR <br />�—�---- <br />SIDE <br />WORK IN ACCORDANCE WITH SECTION 1704.4 OF THE IBC. <br />RATED SHEATHING <br />BRNG <br />BEARING <br />- ---� <br />OC <br />ION <br />- - --- <br />CENTER <br />UNLESS OTHERWISE NOTED, REINFORCING SPLICE LENGTHS AND DEVELOPMENT LENGTHS SHALL BE AS TABULATED <br />_---- <br />_-----------.__-_---_ <br />_ � <br />.J-( <br />-- --- <br />SPECIAL INSPECTION FOR THE ABOVE SYSTEMS SHALL BE AS INDICATED IN THE SPECIAL INSPECTION TABLE BELOW. <br />BELOW; <br />RATED SHEATHING SHALL BE GRADE C-D INT-APA WITH EXTERIOR GLUE OR OSB SHEATHING WITH EXTERIOR GLUE <br />BTWN <br />BETWEEN <br />OPP <br />OPPOSITE <br />STRUCTURAL OBSERVATION OF THE STRUCTURAL SYSTEM BY THE ENGINEER IS NOT REQUIRED. <br />IN CONFORMANCE WITH IBC STANDARD 2303.1.5. <br />CJP ^- <br />COMPLETE <br />_ -j <br />JOINT PENETRATION -� <br />PL <br />_ � - <br />PLATE <br />- - --- - <br />- -�-- <br />- <br />f 3000 PSI c ® <br />GLUE- INATE®TIMBER <br />CLR <br />CLEAR <br />I <br />PLCS <br />PLACES <br />FREQUENCY ARID DISTRIBUTION OF REPORTS - INSPECTION REPORTS SHALL BE PROVIDED FOR EACH DAY ON SITE BY <br />DEVELOPMENT LENGTH <br />LAP SPLICE <br />- -� <br />SPECIAL INSPECTOR. STRUCTURAL OBSERVATION REPORTS SHALL BE PROVIDED AFTER EACH OBSERVATION. REPORTS <br />BAR <br />TENSION <br />COMPRESSION <br />PENSION <br />COMPRESSION <br />GLUE -LAMINATED TIMBER SHALL BE DOUCLAS FIR, FABRICATED IN CONFORMANCE WITH ANSI/AITC STANDARD <br />CMU <br />ICONCRETE <br />MASONRY UNIT <br />PSI <br />POUNDS <br />PER SQUARE INCH <br />SHALL BE DISTRIBUTED TO THE CONTRACTOR, ARCHITECT, ENGINEER AND BUILDING OFFICIAL. <br />SIZE <br />OTHER <br />OTHER <br />A190.1, LATEST EDITION. EACH MEMBER SHALL BEAR AN AITC IDENTIFICATION MARK AND SHALL BE ACCOMPANIED <br />COL .�u <br />� COLUMN <br />-� <br />PSF <br />POUNDS <br />PER SQUARE FOOT <br />SPACIAL INSPECTION <br />TOP BARS <br />BARS <br />ALL BARS <br />TOP BARS <br />BARS <br />ALL BARS <br />BY AN AITC CERTIFICATE OF CONFORMANCE. FABRICATOR SHALL BE CERTIFIED. MEMBERS SHALL BE OF THE <br />CONC <br />j CONCRETE <br />- - <br />I P/T <br />POSTTENSIONED <br />- - <br />#3 <br />22 <br />17 <br />9 <br />28 <br />22 <br />12 <br />FOLLOWING MINIMUM STANDARDS: <br />---_- <br />-- - <br />OPERATION CR!T <br />PERIODIC REMARKS <br />SPAN <br />CO BINATION <br />F <br />CONK <br />_-_ -. <br />CONNECTION <br />PT <br />PRESSURE <br />TREATED <br />#4 <br />29 <br />22 <br />11 <br />37 <br />29 <br />15 <br />-------- <br />---------- ------ <br />SOILS <br />SIMPLE SPAN BEAMS <br />24F-V4 <br />2400 PSI <br />CONT <br />CONTINUOUS <br />RUNE <br />REINFORCING <br />5 <br />36 <br />28 <br />14 <br />47 <br />36 <br />19 <br />-i <br />FOUNDATION BEARING CAPACITY VERIFICATION <br />X <br />CANTILEVER OR MULTI -SPAN BEAMS <br />24F-VS <br />2400 PSI <br />COORD <br />COORDINATE <br />REQ'D j <br />REQUIRED <br />#6 <br />43 <br />33 <br />17 <br />56 <br />43 <br />23 <br />STRUCTURAL STEEL <br />TYPICAL FRAMING DOTES <br />DBL <br />DET <br />DOUBLE <br />SCHED <br />SCHEDULE <br />NOTE: <br />DETAIL <br />- -- <br />SIM <br />SIMILAR <br />- -- ---- <br />FABRICATION & ERECTION <br />X <br />1. ALL LENGTHS ARE IN INCHES. <br />-------._-----_. <br />___� <br />_-- --- j <br />r -- <br />�- ---- ----� <br />2. ALL LAP SPLICES ARE CLASS B. <br />1. ROOF AND FLOOR FRAM{NG <br />DIA <br />DIAMETER <br />SLAB <br />ON GRADE <br />NOTE: <br />3. "TOP BARS" ARE HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE 12 INCHES OF <br />- <br />-------- --- <br />�SOG <br />--- <br />— <br />AL L ITEMS MARKED WITH AN "X" SHALL BE INSPECTED IN ACCORDANCE WITH IBC CHAPTER 17. SPECIAL <br />THAN <br />CONCRETE E IS CAST IN THE MEMBER BELOW THE BAR. <br />° ° <br />PROVIDE 1 1/2 FULL DEPTH BLOCKING FOR JOISTS AND RAFTERS AT ALL SUPPORTS AND AT 8 -0 OC MAXIMUM <br />DIM <br />DIMENSION <br />STD <br />STANDARD <br />INSPECTION SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY DESIGNATED BY THE OWNER. THE <br />UNO. INTERMEDIATE 8'-0" OC BLOCKING NOT REQ'D IF OWB CEILING IS INSTALLED DIRECTLY TO UNDERSIDE OF <br />DIR <br />DIRECTION <br />1 <br />STIFF <br />STIFFENER <br />ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL SHALL BE FURNISHED WITH COPIES OF ALL <br />CONCRETE CODER Off REINFORCING <br />FRAMING. INSTALL DOUBLE JOISTS UNDER PARTITIONS EXTENDING ONE HALF OR MORE OF THE JOIST SPAN. <br />� <br />�- <br />RfSULTS, ANY INSPECTION FAILING TO MEET THE PROJECT SPECIFICATIONS SHALL BE IMMEDIATELY BROUGHT <br />PROVIDE TRUSS BLOCKING PANELS FOR ROOF TRUSSES AT SUPPORTS AND SHEAR WALLS, AND WHERE INDICATED <br />EA <br />_1- <br />EACH <br />- _W--�-__- ._._- <br />E STLpeSTEELg�4P1� <br />- <br />TO THE ATTENTION OF THE DESIGN TEAM. <br />�, :- <br />am.� <br />® <br />9--- <br />SOILS REPORT: NOT AVAILABLE AT TIME OF DESIGN <br />ALLOWABLE SOIL PRESSURE: 2000 PSF (ASSUMED; TO BE FIELD VERIFIED DURING CONSTRUCTION) <br />�� 1. . �► � � — �� trr � �A f". ". ►x t: s � A: <br />a <br />r <br />x0jilF __ - is <br />#6 BARS AND LARGER 2" <br />#5 BARS AND SMALLER 1 1/2" <br />CONCRETE NOT EXPOSED TO EARTH OR WEATHER: <br />SLABS, WALLS AND JOISTS 3/41' <br />COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1 1/2" <br />CONCRETE GENERAL MOTES <br />ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED AND PROPERLY PREPARED IMMEDIATELY PRIOR TO <br />POURING OF CONCRETE. DOWEL STEEL SHALL BE THE SAME SIZE AND SPACING AS MAIN REINFORCING DETAILED <br />BEYOND JOINT, <br />BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL NOT BE FIELD BENT UNLESS SO DETAILED OR <br />APPROVED BY THE STRUCTURAL ENGINEER. <br />SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE AND <br />OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES. PROVIDE 3/4" CHAMFER AT ALL CORNERS EXCEPT AS <br />NOTED. <br />LUMBER <br />ALL GRADES SPECIFIED ARE MINIMUM GRADES REQUIRED. ALL LUMBER SHALL BE IN ACCORDANCE WITH WWPA <br />GRADING RULES, KILN -DRIED TO MC 19 AND OF THE FOLLOWING MINIMUM STANDARDS: <br />NOTEDREFER TO PLAN NOTES, SCHEDULES, AND DETAILS FOR MORE SPECIFIC LUMBER SIZE AND GRADE REQUIREMENTS. <br />UNLESS WPLANS,ALL WOOD AND WOOD-BASEMEMBERSPO. D TO WEATHER OR IN <br />ON PLANS AND DETAILS. <br />2. DIAPHRAGM NAILING <br />ALL SHEAR WALLS, FLOOR AND ROOF DIAPHRAGM MAILINGS SHALL BE AS CALLED OUT ON SCHEDULES OR ON THE <br />PLANS. EXTERIOR WALLS NOT INDICATED AS SHEAR WALLS SHALL BE SHEATHED AND NAILED TO SUPPORTING <br />FRAMING WITH 8d NAILS AT 6 OC AT ALL PANEL EDGES AND 12" OC AT ALL INTERMEDIATE SUPPORTS. <br />THE USE OF NAIL GUNS WILL BE APPROVED IF NAILING INTO THE DIAPHRAGMS CAN BE INSTALLED FLUSH WITH <br />FACE OF SHEATHING. NAIL PENETRATIONS GREATER THAN 1/16" ARE NOT ACCEPTABLE. <br />3. ALLOWABLE STUD AND PLATE PENETRATIONS <br />CUTTING AND/OR NOTCHING OF WOOD STUDS OR PLATES SHALL NOT EXCEED 25% OF THE STUD/PLATE WIDTH IN <br />EXTERIOR AND BEARING WALLS AND SHALL NOT EXCEED 40% OF THE STUD/PLATE WIDTH IN ANY NON -BEARING <br />PARTITIONS. BORED HOLE DIAMETER IS LIMITED TO 40% OF STUD/PLATE WIDTH IN ANY STUD AND MAY BE 60% IN <br />NONBEARING PARTITIONS OR IF STUD IS DOUBLED, MAINTAIN 5/8" MINIMUM EDGE DISTANCE FROM HOLE EDGE. <br />EXISTING BUILDING <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS, MEMBER SIZES AND CONDITIONS OF THE EXISTING BUILDING <br />DEPICTED IN THE DRAWINGS, AND NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES FOR POSSIBLE <br />REDESIGN. <br />CONTRACTOR RESPONSIBLE FOR COMPLETELY SEALING ALL AREAS WHERE EXISTING ROOF MATERIAL IS <br />PENETRATED OR REMOVED. PROVIDE WATER PROOFING AS REQUIRED BY THE ARCH. <br />GENERAL <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS FOR COMPATIBILITY BEFORE PROCEEDING. ANY <br />DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION STABILITY AND TEMPORARY SHORING AS NECESSARY UNTIL <br />PERMANENT SUPPORT AND STIFFENING ARE INSTALLED. <br />CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL <br />ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS <br />ONLY WILL NOT SATISFY THIS REQUIREMENT. <br />DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT <br />SPECIFICALLY INDICATED BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF <br />CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL <br />ENGINEER. <br />Oa/ 0912021 <br />lal <br />.�z <br />�f <br />i� <br />I <br />i <br />r � - <br />