My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
523 61ST ST SE 2019 Plans 2022-12-16
>
Address Records
>
61ST ST SE
>
523
>
Plans
>
523 61ST ST SE 2019 Plans 2022-12-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2022 8:56:33 AM
Creation date
12/16/2022 8:52:38 AM
Metadata
Fields
Template:
Address Document
Street Name
61ST ST SE
Street Number
523
Permit
C1907-001
Year
2019
Notes
3 BEDROOM 2 BATH 2ND STORY SFR ADDITION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
POST CERTIOCATEL WI MIN-1 OF FIB ICAO PANE - <br />DESIGN CONDI ]IONS: <br />R302.1 INTERIOR DESIGN CONDITION& THE INTERIOR DESIGN TEMPERATURES USED FOR HEATING AND COOLING LOAD CALCULATIONS <br />SHALL BE A MAXIMUM OF 72F V2`C) FOR HEATING AND MINIMUM OF 757 24-C) FOR COOLING. <br />R302.2 EXTERIOR DESIGN CONDI ONS, THE HEATING OR COOLING OUTDOOR RSIGN TEMPERATURES SHALL BE SELECTED FROM <br />APPENDIX C. <br />BUILDING THERMAL ENVELQELREQWKMEKa <br />INSULATION: <br />UNLESS NOTED OTHERMSE, INSULATION TO BE PER WSEC TABLE R402.1,11, CLIMATE ZONES 5 MD MARINE 4, MD THE SPECIFI <br />REQUIREMENTS OF SECTIONS R402.2.1 THROUGH R402.2,11. <br />FENE5)BA J10N: <br />R402,3 FENESTRATION (PRESCRIPTIVE), IN ADDITION TO THE REQUIREMENTS OF SECTION R40Z FENESTRATION SHALL COMPLY N <br />SECTIONS R4OZ3,1 THROUGH R4013.5. <br />2015 WASUINGI-ON STATE SINGLE-FAMILY RESIDENII& ENERGY Q0-DE <br />TAM R403.6.1 <br />MECHANICAL VENTILATION SYSTEM FAN EFFICAa <br />RATE MINIMUM <br />MINIMUM EMCACY <br />IMA <br />11AKWAIT <br />CFM) <br />(CFM/WATO <br />1.4 CFM ATT <br />18 ffM ""ATT <br />TABLE R4021.1 <br />NSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa <br />CLIMATE ZONE <br />5 AND MARINE 4 <br />FENESTRATION U- <br />0,30 <br />SKYLIGHT' U-rum <br />0.50 <br />GLAZED FENESTRA11ON SHG& <br />RR <br />COUNG R-VALUE <br />4 <br />WOOD FRAME WALLOW R-VALUE <br />21 int <br />MASS WALL R-VALUO <br />21/21 <br />FLOOR R-VALUE <br />309 <br />BELOW-GRADUP WALL R-VALUE <br />10/15L21 int+TB <br />Ste' R-VALUE & DEPTH <br />102 ft <br />For SI- I foot=304.8mrn, 6--continuous insulation, int= intermediate Iraming <br />, R—Wkm are min Imiffia. 11—fadars cad SRO are ffladmifn& men Lisulaft is <br />lastdied IF, a cavity AM is few umn the label of "o thmmess of the loadfift, <br />We empressed RP of We Insulation foom k9m-dix Table A101.4 &%d not be Im <br />thon the R—vdue speciffed in the table, <br />h be fenestration 11—factor cduffin excludes sk%Adt& The SHGC eduma qMies- to (A <br />dozed WeaTrod ffl. <br />0 'I0/15/21,+T8' mma R-10 coatinuous Watha on the exterior of the well, or <br />R-15 continuous Insulation on Um inWor of the wad, or R-21 comfy insulation plus a <br />ftwid We,* bet wen the dab and the basmeat WI at the interior of the boament <br />wall. '10115121.+IW shall be permitted to he met with R-13 coity Insulation on the <br />Interior of the basement well Plus R-5 continuous insulation on the Interior or oxtorW <br />of ft wall, 0TOv memo thermal break between floor dab and boament wall, <br />® R-10 easURUOUS Insulation is required under heated slab on grade fim See 1140Z29.1. <br />' There are no SHGC requirements in the Marine Zone, <br />40 Rem -ad. <br />1 The second R—vdue applies 4m more than half the lasulation is an the Interior of <br />the mass Well, <br />I New"& <br />For 0hoo rafter— or js[st—vailled cdihr, the Insulation may be roduoW to R-31L <br />lot. (kitermediato toming) denustes standard kwaing 16 lfl6ee on cater vAth <br />headers insulated with a minhum of R-10 inaulaMa. <br />11 Log and adid timber walls with a minimum omega thickaess of 3,5 inches (we <br />cxanpl from this insulation requiromeaL <br />F21MUM <br />a In addition, inspection of log wells shall be a with the provisions of ICC-400. <br />ADDITION& ENERGY EFFICIENCY REM91REMENTS- <br />R40&I L THIS SECHOIN ESTABUW—S OPTIONS FOR AWRION& MTERIA TO BE MET FOR ONE— MD TWO—FAMLY DKUAW, ANO TOWHWSES, AS WINED IN SECTION 101.2 OF THE <br />INTERNATIONAL RESIDWRAL W TO OWSTRATE ONPUARM NTH M M <br />OF EVERETT <br />REVI-r-WED FOR PERMF <br />1 <br />C:) <br />. .... <br />> <br />L-Lj <br />(L- <br />(-D <br />0 <br />Lo 0) <br />W "-,a 00 0 <br />C3) .0 <br />to <br />ca <br />U') <br />Lt- 0 W <br />Z <br />W <br />Z <br />En <br />< <br />Ld <br />6f <br />LA <br />> <br />LLJ <br />Ld <br />> <br />Ld <br />< <br />Uf <br />z <br />z <br />Ld <br />
The URL can be used to link to this page
Your browser does not support the video tag.