My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2323 74TH ST SE 2021 Plans 2022-12-16
>
Address Records
>
74TH ST SE
>
2323
>
Plans
>
2323 74TH ST SE 2021 Plans 2022-12-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2022 9:01:56 AM
Creation date
12/16/2022 8:57:49 AM
Metadata
Fields
Template:
Address Document
Street Name
74TH ST SE
Street Number
2323
Permit
B2102-007
Year
2021
Notes
SFR TO ADULT FAMILY HOME
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APULT FAMILY HOME <br />ONNER, <br />NA667ACE HIRUT/65IOR615 YAFET <br />2323 -14TH 5T 5E, EVERETT NA cia2O5 <br />GENERAL NOTES <br />C 0 D rE <br />DESIGN IS IN ACCORDANCE WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) <br />FOUNDATIONS <br />EXTEND FOOTINGS TO FIRM UNDISTURBED SOIL, ASSUMED BEARING CAPACITY OF 1500 PSF. ALL <br />EXTERIOR FOOTINGS SHALL EXTEND A MINIMUM OF V-6" BELOW ADJACENT EXTERIOR FINISHED GRADE. <br />CAST -IN -PLACE CONCRETE <br />F'c = 3,000 PSI @ 28 DAYS. MINIMUM 5-1/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A <br />MAXIMUM OF 6-3/4 GALLONS OF WATER PER 94# SACK OF CEMENT. NO SPECIAL INSPECTION REQUIRED. <br />V) <br />TOTAL AIR ENTRAINMENT SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. MAXIMUM <br />SIZED AGGREGATES IS 1-1/2 INCHES, MAXIMUM SLUMP IS 4 INCHES, ALL REINFORCING STEEL DOWELS, <br />ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN POSITION PRIOR TO POURING CONCRETE. <br />ANCHOR BOLTS FOR PRESSURE TREATED SILL PLATES TO FOUNDATION WALLS TO BE Y8" DIAMETER WITH <br />7 INCH MINIMUM EMBEDMENT INTO CONCRETE AND MAXIMUM SPACING OF 2 FEET ON CENTER UNLESS <br />Lij C11_4 <br />NOTED OTHERWISE ON THE PLANS. MINIMUM 2 BOLTS PER SILL PLATE PIECE. ONE BOLT TO BE PLACED <br />0 <br />WITHIN 6 INCHES OF EACH END OF THE SILL PLATE. <br />CARPENTRY <br />ALL GRADES SHALL CONFORM TO WWPA GRADING RULES FOR WESTERN LUMBER, LATEST EDITION. <br />PROVIDE CUT WASHERS UNDER ALL NUTS AND BOLTS BEARING AGAINST WOOD. ALL WOOD IN CONTACT <br />WITH CONCRETE SHALL BE PRESSURE TREATED PER PRESERVATIVE TREATMENT NOTE. FASTENERS <br />INSTALLED IN PRESERVATIVE TREATED WOOD SHALL BE HOT -DIPPED GALVANIZED PER I.R.C. SECTION <br />C) <br />�Z* <br />R319.3. NAILING SHALL CONFORM WITH I.R.C. TABLE R602.3(1) & R802.10 OR I.B.C. TABLE 2304.9.1. ALL <br />STRUCTURAL LUMBER SHALL BE AS NOTED BELOW: <br />2x STUDS HEM -FIR #2 ------------------- Fb = 850 PSI <br />2x FLOOR & ROOF JOIST HEM -FIR #29 ------------------- Fb = 850 PSI <br />L_u <br />4x BEAMS DOUG-FIR/LARCH #2 ---------- Fb = 875 PSI <br />C) <br />6xBEAMS DOUG-FIR/LARCH #2 ---------- Fb ® 850 PSI <br />COLUMNS DOUG-FIR/LARCH #2 ---------- Fb = 875 PSI <br />CNI w <br />LUMBER NOT NOTED DOUG-FIR/LARCH #2 ---------- Fb = 850 PSI <br />MISCELLANEOUS HANGERS TO BE PROVIDED BY SIMPSON COMPANY, ALL HANGERS SHALL BE FASTENED <br />TO WOOD WITH PROPER NAILS. ALL HOLES SHALL BE NAILED. MACHINE BOLTS TO BE A-307. ANCHOR <br />BOLTS INTO CONCRETE SHALL BE %" DIAMETER WITH 7 INCHES OF EMBEDMEND INTO CONCRETE UNLESS <br />NOTED OTHERWISE ON THE PLANS. ALL NAILS SHALL BE COMMON WIRE NAILS. NAILING SHALL BE IN <br />ACCORDANCE WITH I.B.C. SCHEDULE. 16d COMMON NAIL DIAMETER - (0.162 INCH). LAMINATED STUDS <br />SHALL BE NAILED WITH (2) ROWS 16d COMMON NAILS @ 6" O.C. <br />ljmg���E <br />SHEATHING SHALL BE Y4 INCH TONGUE & GROOVE, A.P.A. RATED SHEATHING. SPAN RATING 4 V24 WITH <br />LONG DIMENSION PERPENDICULAR TO SUPPORTS. UNLESS NOTED OTHERWISE NAIL WITH 10d COMMON u_j <br />NAILS AT 6 INCHES ON CENTER AT SUPPORTED PANEL EDGES & 10 INCHES ON CENTER AT INTERMEDIATE <br />SUPPORTS. THE FLOOR SHEATHING SHALL BE GLUED TO THE JOIST AND THE TONGUE AND GROOVE <br />JOINTS WITH AN APPROVED ADHESIVE, <br />ROOF SHEATHING w U) <br />SHEATHING SHALL BE Zia" A.P.A. RATED SHEATHING. SPAN RATING 33/16, INSTALLED WITH LONG DIMENSION >_ <br />ACROSS SUPPORTS. PANEL END JOINTS SHALL OCCUR AT SUPPORTS. NAIL PANEL EDGES WITH 8d NAILS <br />AT 4 INCHES ON CENTER AND 10 INCHES ON CENTER AT INTERMEDIATE SUPPORTS. <br />WALL SH'ATHING 0 <br />SHEATHING TO BE Ym" A.P.A. RATED SHEATHING. SPAN RATING 2%. PANEL END JOINTS SHALL OCCUR AT <br />SUPPORTS. NAIL PANEL EDGES WITH 8d NAILS AT 4 INCHES ON CENTER AND 10 INCHES ON CENTER AT <br />INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE ON THE DRAWINGS. <br />REINFOR 'IMENT <br />fy = 40,000 PSI FOR #5 & SMALLER <br />fy = 60,000 PSI FOR #6 & LARGER <br />NOTE: ALL BOLTS, WASHERS, NAILS, SCREWS, HANGERS AND FRAMING STRAPS THAT COME INTO <br />CONTACT WITH ACC? TREATED LUMBER SHALL BE STAINLESS STEEL OR HOT -DIPPED GALVANIZED STEEL. <br />WALL NOTES: <br />tgM L�_41-110— <br />A2 EXISTING MAIN FLOOR PLAN AND EXISTING LOFT i I EaDocumenIf-11t date: <br />01/25/21 <br />A3 DEMO PLAN <br />Document Phase: <br />A4 PROPOSED MAIN FLOOR PLAN AND EXISTING LOFT FOR PERMIT <br />A5 DETAILS <br />A— REVISION <br />A6 EXISTING AND PROPOSED FRONT AND RIGHT ELEVATIONS DUE TO <br />COMMENT#1 <br />A7 2015 WSEC DATED <br />02.27.21 <br />AlOF A7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.