Laserfiche WebLink
16A 16E 19A 17D (N) WALL & STRINGER MOUNTED <4" B/W GUARDRAIL <br />A5.4 1A 5.4 A5.5 A5.3 ALUMINUM HANDRAIL REF <br />16B A3.4 16C 19B 18C 4 17B 8D POST & WALL <br />6D/A5.5 FOR MOUNT BRACKET <br />A5.5 A5.5 A5.5 A5.2 A5.4 A5.3 A5.3 <br />18A TYP ATTACHMENT �-Yp (E) MAN DOOR RE/RE; <br />A5.2 1 C REF 6/A5.3 <br />TYP �'- - � A5.4 �- --� <br />OPP0 0 0 0 0 0 �� a a o <br />(E) CONC JOINT; REF 6B/A5.3 <br />FOR MEM-1 TERMINATION @ <br />MAN DOOR <br />1 DN (E) CONC IN <br />A2.3 .,SLOPE <br />1 BHALLWAY TO <br />A5.4 REMAIN, TYP <br />TYP / <br />�(N) TOP MOUNTED <br />1C ALUMINUM GUARDRAIL <br />A2.2 <br />1 D SLOPE ^8A 6A 6B <br />A5.3 A5.5 A5.5 O <br />\\ <br />A3.2 9 TYP @ TYP @ 0 <br />A5.5 STRINGER WALKWAY m <br />8B & LANDING (E) STRINGERS & TREADS; <br />A5.3 MEM-1 RE/RE W/ (N) RISER <br />TYP @ CLOSURE PLATES, TYP; <br />SID-1 REF 19/A5.5 <br />(N) WALL MOUNTED ALUMINUM <br />GUARDRAIL, TYP; REF SHEET <br />A3.3 FOR ENLARGED ELEVS <br />TOP FLOOR <br />STAIR PLAN <br />"TYP @ <br />1 B SID-1 <br />A2.3 <br />11 B <br />Ki-cNi, ... <br />A2.2 <br />1D <br />A3.2 <br />1A 1A <br />�A2.2 A2.3 <br />1B <br />A2.2 <br />TYP @ (E) <br />SIDING <br />(E) STRINGERS & TREADS <br />•. <br />® <br />�� <br />17D <br />CLOSURE PLATES, TYP; <br />m <br />A5.5 <br />A5. <br />REF . . 5.5 <br />,•= ' <br />h <br />• <br />'=YP <br />TYP TYP <br />SLOPE <br />INTERMEDIATE <br />0 <br />FLOOR STAIR PLAN <br />(E) SOG TO REMAIN <br />UNDISTURBED; REF <br />SHEETS A0.3, A1.2 & A1.3 <br />-(E) CONC FOR SOG REPLACEMENT <br />WALKWAY @ PONDING LOCATIONS; <br />WHERE COORD EXTENT OF SOG <br />OCCURS REPLACEMENT W/ ARCH <br />9A <br />-" TYP @ <br />SID-1 <br />113 <br />A2.3 <br />1C <br />A2.2 <br />9� <br />`'TYP @ <br />-qTRIN(,FR <br />(N) STRINGER MOUNTED <br />ALUMINUM GUARDRAIL W/ <br />HANDRAIL <br />' <br />16FA5.4 <br />(N) WALL &STRINGER <br />MOUNTED ALUMINUM <br />16G <br />19B <br />(E) MAN DOOR RE/RE; <br />HANDRAIL; REF <br />5.4 <br />kA5.V <br />REF 6/A5.3; RE/REP @ <br />6D/A5.5 FOR MOUNT <br />16D <br />rl C <br />BLDG 5; COORD W/ ARCH <br />BRACKET <br />A5.5 <br />A5.4 <br />ATTACHMENT <br />(E) CONC JOINT; REF 6B/A5.3 <br />FOR MEM-1 TERMINATION @ <br />MAN DOOR <br />UP (E) CONC IN <br />SLOPE HALLWAY TO <br />REMAIN, TYP <br />- 16C 16D 3 <br />U) 613 <br />r 5.5 <br />0 TYP @ <br />m WALKWAY <br />8C NOTE: PLAN APPLIES TO <br />k5.3 <br />TYP @ (E) 2ND & 3RD FLOOR FOR <br />SIDING STAIR TOWER TYPE 3. <br />A5.4 A5.4 S2 <br />\-(N) TOP MOUNTED <br />ALUMINUM GUARDRAIL <br />(N) STRINGER MOUNTED ALUMINUM <br />GUARDRAIL W/ HANDRAIL, TYP <br />(E) STRINGERS & TREADS; RE/RE W/ (N) <br />(E) BRICK, RE/RE AS RISER CLOSURE PLATES, TYP; REF 19/A5.5 <br />REQ'D TO ACCOM WORK (N) WALL & STRINGER MOUNTED <br />ALUMINUM HANDRAIL; REF 6D/A5.5 FOR <br />MOUNT BRACKET ATTACHMENT <br />A5.2 A5.4 16D (E) MAN DOOR TO <br />TYP A5.5 REMAIN UNDISTURBED <br />40 UP <br />16A 8 <br />� <br />-i TYP <br />6A <br />5.5 <br />TYP <br />GROUND FLOOR 1A 1A 9A 17 <br />C STAIR PLAN A2.2 A2.3 A5.1 A5.: <br />1B SIM, TYP <br />A2.2 @ (E) <br />SIDING <br />1 STAIR TOWER TYPE 2 & 3 - PLANS & SECTION <br />3/8" = 1'-0:' <br />z <br />1 <br />\\-(N) STRINGER MOUNTED ALUMINUM <br />GUARDRAIL W/ HANDRAIL <br />SIDING LEGEND <br />0 LOCATION OF (E) SIDING <br />LOCATION OF SID-1 OR TRIM INSTALLATION <br />6B <br />A5.2 <br />SIM <br />_ LIGHT-1, TYP <br />(E) SOFFIT @ TOP <br />FLOOR TO REMAIN <br />18A 4'-0" MAX TYP. <br />A5.2 (E) VINYL SIDING; RE/RE <br />OPP _ AS REQ'D TO ACCOM <br />SID-1, TYP I WORK, TYP <br />1 B (N) TOP MOUNTED <br />A2.3 ALUMINUM GUARDRAIL, TYP <br />in Id hl7i7:� TOP FLOOR <br />A2.2 <br />TRIM-2, TYP; PNT-6 _ <br />(N) WALL MOUNTED <br />ALUMINUM <br />GUARDRAIL, TYP; <br />REF SHEET A3.3 <br />FOR TYP _ <br />ENLARGED ELEVS <br />8B <br />A5.3 19B 3 <br />TYP @ A5.4 S2.0 <br />SID-1 <br />1 B I } INTERMEDIATE FLOOR <br />SIM TYP @A5.4 <br />INTERMEDIATE <br />FLOOR 6B <br />A5.2 l <br />SIM <br />6A <br />A5.2 <br />TYP @ <br />SID-1 <br />18B <br />A5.2 <br />TYP <br />8C <br />5.3 <br />TYP <br />(N) STRINGER MOUNTED <br />ALUMINUM GUARDRAIL W/ <br />HANDRAIL, TYP <br />GROUND FLOOR <br />9A 9A 9 4 _ 8 <br />A5.1 A5.1 A5.5 (E) WD A5.4 S2.0 <br />TYP @ SIM @ (E) TYP STRINGER, @ <br />SID-1 SIDING RE/RE; PNT-7 WALL <br />NOTE: SECTION SIM @ <br />SECTION STAIR TYPE 3 W/ 4 FLOORS. <br />D <br />i6D <br />A52 <br />S�,p�. <br />TYP <br />4f, <br />REV-4, TYP; REF <br />7/A5.1; ALIGN W/ <br />CORNERS OF <br />STAIR OPENING <br />ARCH <br />18C <br />A5.2 <br />_ <br />TYP <br />PLAN NOTES: <br />1. STAIR TYPES: PLANS & SECTIONS OF STAIR TYPES 1 - 3 TYPICALLY <br />REPRESENT (E) STAIRS; SLIGHT VARIATIONS TO LAYOUT & INTERFACES MAY <br />OCCUR. CONTRACTOR TO VERIFY (E) CONDITIONS IN FIELD. COORD W/ ARCH <br />FOR CLARIFICATIONS AS NEEDED. <br />2. GUARDRAILS: GUARDRAILS SHOWN HEREIN ARE GENERAL & MAY NOT <br />REPRESENT ALL GUARDRAIL CONFIGURATIONS. REF NOTES, PLANS & ARCH <br />FOR VARIATIONS. <br />3. STAIRS & WALKWAYS: DIMENSIONS VARY B/W STAIR TOWERS; NUMBER OF <br />GUARDRAIL POSTS VARY, CONTRACTOR TO VERIFY. <br />4. SLOPING: SLOPE ELEVATED WALKWAYS & LANDINGS MIN 1/4" PER FT @ ALL <br />LOCATIONS. INSTALL PLY-1 O/ TAPERED SLEEPERS, TYP. COORD LOCATIONS <br />& ANGLES OF VALLEYS W/ ARCH. LAST RISER @ TOP STEP SHALL MATCH (E), <br />TYP. <br />5. (E) STAIR STRINGERS & TREADS TO BE RE/RE W/ (N) RISER CLOSURE PLATES, <br />TYP. REFER TO 17/A5.5 FOR RISER CLOSURE DETAIL. REF 19/A5.4 FOR <br />STRINGER CONNECTION @ BOTTOM. <br />6. REFER TO STRUCT, SECTION 01 10 00 DESCRIPTION OF THE WORK & SHEET <br />A0.3 FOR REFRAMING & SELECT STRUCT COMPONENT REPAIR, WHERE <br />OCCURS. COORD W/ ARCH. <br />7. GROUND FLOOR STAIR GUARDS NOT SHOWN FOR CLARITY; RE/REP ALL <br />STAIR GUARDS, CONFIGURATIONS VARY; CONTRACTOR TO VIF. <br />8. GROUND FLOOR WALL MOUNTED GUARDRAILS & HANDRAILS EXIST @ <br />SELECT LOCATIONS; RE/REP ALL GROUND FLOOR GUARDRAILS & <br />HANDRAILS; CONFIGURATIONS VARY; CONTRACTOR TO VIF. <br />DETAIL REFERENCE NOTES <br />1. SOFFIT VENTILATION: @ ALL ELEVATED WALKWAYS EXCEPT TOP FLOORS, <br />INSTALL VENT-1, TWO PER SOFFIT. LOCATE VENTS CONSISTENT DIMENSIONS <br />FROM FRONT EDGES & BACK WALLS, TYP. REFER TO 8D/A5.3. COORD W/ <br />ARCH FOR LOCATIONS. <br />2. SID-1 TRANSITION: REFER TO 6/A5.1 FOR TYPICAL SID-1 TRANSITION DETAILS. <br />3. BEAM TRANSITION DETAILS: REFER TO 11 & 16/A5.3 FOR BEAM TO WING WALL <br />TRANSITION DETAILS, TYP. <br />4. GUARDRAIL ELEVATIONS: REF SHEETS A3.3 & A3.4 FOR TYPICAL GUARDRAIL <br />CONFIGURATIONS. <br />5. GUARDRAIL & HANDRAIL DETAILS: REF SHEET A5.5 FOR TYP <br />HANDRAIL/GUARDRAIL INTERFACE DETAILS. REF 8A/A5.3 FOR TYP <br />GUARDRAIL POST CONNECTION DETAIL. <br />6. BASE OF SIDING: REFER TO 9/A5.1 & 8B & 8C/A5.3 FOR TYP BASE OF SIDING <br />DETAILS. <br />7. TYP STAIR STRINGER INTERFACE DETAILS: REF 16 & 19/A5.4 & 19/A5.5. <br />8. STRUCTURAL: REF SHEETS S1.0 & S2.0. <br />SECTION NOTES <br />1. WALL MOUNTED GUARDRAILS: WALL MOUNTED GUARDRAILS SHALL BE <br />INSTALLED LEVEL @ ALL TOP & BOTTOM RAILS. ESTABLISH 42" HIGH MIN <br />WHERE GUARDRAILS MEET BLDG. <br />2. LANDING & WALKWAY FRAMING, TAPERED SLEEPERS & SHEATHING NOT <br />SHOWN FOR CLARITY. <br />3. REF SHEET A3.4 FOR TYP GUARDRAIL & HANDRAIL ELEV CONFIGURATIONS @ <br />LANDINGS. <br />AM E NTOG RO U P <br />710 2nd Avenue, Suite 400 <br />Seattle, WA 98104 <br />amentogroup.com <br />9016 REGISTERED <br />ARCHITECT <br />LISA CLARK MOE <br />STATE OF WASHINGTON <br />The documents created by the <br />Architect and its Consultants <br />for this project are instruments <br />of the Architect's service. The <br />Architect retains all common <br />law, statutory and other <br />reserved rights, including the <br />copyright. The Architect's <br />documents shall not be used <br />by anyone on any other <br />project, except with the <br />Architect's written permission. <br />GREENS OF <br />MERRILL CREEK <br />APARTMENTS <br />BLDG 11 <br />1707 MERRILL CREEK PKWY <br />EVERETT, WA 98203 <br />STAIR <br />REMEDIATICJN <br />SCOPE OF <br />REPAIR <br />WATERPROOFING & <br />FLASHING DETAILS <br />PERMIT SET <br />PROJECT #: <br />070042 <br />DRAWN BY: <br />AJL, DGS, HLS <br />CHECKED BY: <br />MFV, MNM <br />REVISIONS: <br />10-16-2020 PERMIT SET <br />BLDG DEPT: <br />DATE: <br />10-16-2020 <br />SHEET TITLE: <br />STAIR TYPES 2 & <br />3 PLANS & <br />SECTION <br />BUILDING TYPE: <br />N/A <br />SHEET #: <br />■ <br />