1707 MERRILL CREEK PKY BLDG 12 2020 Plans 2022-12-16
>
Address Records
>
MERRILL CREEK PKY
>
1707
>
Plans
>
1707 MERRILL CREEK PKY BLDG 12 2020 Plans 2022-12-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2022 10:07:40 AM
Creation date
12/16/2022 10:05:31 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
1707
Unit
BLDG 12
Permit
B2011-015
Year
2020
Notes
REFRAMING SELECT STAIR TOWERS, LANDINGS, STRIP AND RECLAD OF
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I(E) SIDING; RE/RE <br />TO ACCOM WORK <br />(E) PLY, TYP � I <br />I <br />(E) GYP, TYP <br />7 <br />2 LAYERS OF WRB; <br />(E) WRB; <br />FOLD BACK <br />PROPERLY LAP W/ <br />I - <br />TO ACCOM <br />(E) WRB & FF-1 II <br />WORK; <br />I PROPERLY <br />FF-1; INSTALL <br />LAP W/ FF-1 <br />INTO RO & MIN <br />I <br />9" ONTO GYP <br />FACES @ INT & <br />EXT OF DOOR <br />SHIM AS <br />MEM-1 W/ INTEGRAL FF-5 DOOR-1 OR (E) DOOR TO NOTE: REF 8D/A5.3 FOR <br />& FF-6, SET IN SLNT-4 BE RE/RE WALKWAY FASCIA. <br />2 W/O HEMMED EDGE 0/ BOTTOM RAIL <br />MEM-1 @ BASE OF <br />WALL, BELOW ALUM MEM-1 W/ <br />- - - - - - THRESHOLD @ DOOR INTEGRAL FF-6 O/ <br />- - - - --I ONLY &UNDER ALUM <br />ALUM THRESHOLD, SET 0/ SHIM, SET IN <br />CONT GASKET STRIPS, SLNT-4 <br />INSTALL FILLET SLNT-4 @ <br />MEM-1, (E) CONC & JAMBS; <br />I I I <br />DO NOT FASTEN <br />THRESHOLD THROUGH PLY-1 0/ TAPERED <br />- - - - - _ - MEM-1 SLEEPERS; ROUTE <br />EDGE TO ACCOM <br />CONT EPDM ISOLATION MTL #18 <br />STRIP @ CONIC, TYP <br />v <br />REQ D <br />BR & SLNT-1, TYP S.S. COUNTERSUNK <br />DOOR-1 OR PLY-1 BR & FASTENERS; PROVIDE TOP MOUNTED GUARDRAIL @ WALKWAY <br />SLNT-4 A <br />(E) DOOR TO <br />GASKETS BELOW ALUM, TYP <br />BE RE/RE <br />TAPERED <br />SLEEPERS <br />NWALKWAY <br />(E) COC <br />GYP-1 OR (E) <br />ASSEMBLY TO <br />GYP <br />A HEAD <br />B SILL @ CONC <br />REMAIN INSTALLED <br />PLY-2 OR (E) <br />NOTE: SIDING NOT <br />PLY <br />SHOWN FOR CLARITY. <br />(E) WRB, FOLD BACK SHIM AS REQ'D <br />TO ACCOM WORK <br />DOOR-1 OR <br />- - - (E) DOOR TO <br />--_ -_=- 10 BE RE/RE <br />FF-1; INSTALL <br />INTO RO & MIN <br />1 9" ONTO GYP <br />FACE @ INT & <br />EXT OF DOOR <br />Io <br />BR & SLNT-1 @ <br />(E) SIDING RE/RE JAMBS, TYP <br />TO ACCOM WORK 2 LAYERS OF WRB; SET IN <br />CONT BEAD OF SLNT-5 @ <br />JAMB DOOR FRAME <br />C <br />DOOR DETAILS - SECTIONS <br />3" = 1'-0" <br />NOTES <br />1. ALL (E) ELEVATED LANDING DOORS & FRAMES TO BE RE/RE <br />TO ACCOM WORK. ONE DOOR @ BLDG 5 SHALL BE RE/REP, <br />REF 1 B/A3.2 & ARCH FOR ADD'L INFO. <br />2. REF SHEETS A3.1 & A3.2 FOR TYP DOOR LOCATIONS. <br />3. DOORS & FRAMES @ GROUND FLOOR TO REMAIN <br />INSTALLED. <br />4. ALL DOORS @ MEM-1 SHALL RECEIVE (N) ALUM THESHOLDS; <br />REF 6B/A5.3. <br />�3 n i�1 NOTE: SADDLE MAY <br />2 LAYERS OF WRB; O/ <br />1 _ 4 SAM-1 @ VARY; COORD W/ ARCH <br />� <br />MTL #23; PROPERLY CORNERS; <br />LEAVE PAPER NOTE: REF 16/A5.3 FC <br />LAP O/ MEM-1 1 I BACKING IN INSTALLATION. <br />REF 17D/A5.3 3 I PLACE WHEN <br />l INSTALLED 0/ <br />FOR AXON 1/ MEM-1 <br />PLY-1 <br />0/ <br />1 NOTE: <br />TAPERED MEM-1, <br />SLEEPERS SIDING & <br />MTL #18 NOT <br />II SHOWN FOR <br />• 4" 4" <br />CLARITY. SADDLE @ PLANAR 0 <br />(E) OR (N) A EXTERIOR CORNER <br />WD BEAM I <br />1 2 LAYERS <br />OF WRB W/ <br />SAM-1 @ <br />WALKWAY CORNERS <br />TRANSITION @ (E) SIDING - AXON <br />NO SCALE MEM_MTL _WW_AX_001 <br />02 LAYERS OF WRB; O/ <br />4 SAM-1 @ <br />_ <br />CORNERS; <br />MTL #20; PROPERLY <br />LEAVE PAPER <br />LAP 0/ MEM-1 <br />I <br />BACKING IN <br />REF 17A/A5.3 0 I <br />I <br />PLACE WHEN <br />FOR AXON I I � <br />� 1 <br />INSTALLED O/ <br />l <br />MEM-1 <br />PLY-1 <br />I � <br />I <br />0/ <br />TAPERED <br />NOTE: <br />SLEEPERS <br />' <br />MEM-1, <br />SIDING & <br />I <br />MTLS #14 & <br />#18 NOT <br />(E) OR (N) <br />SHOWN FOR <br />WD BEAM <br />I <br />CLARITY. <br />1 2 LAYERS <br />OF WRB W/ <br />SAM-1 @ <br />WALKWAY <br />CORNERS <br />16 TRANSITION @ SID-1 - AXON <br />V/F <br />4" <br />VIF <br />CONT DRIP HEMMED <br />EDGE CLEAT EDGES, TYP <br />SADDLE @ TOP OF 4 <br />E STRINGER @ WALKWAY <br />NU 1 1=: REF- 1(;/A5 <br />FOR SECTION. <br />4" <br />CLEAT <br />NOTE: REF 16B/A5.4 <br />FOR INSTALLATION. <br />2 LAYERS OF <br />WRB <br />-TOP MOUNTED <br />GUARDRAIL POST W/ <br />BASE PLATE & ALUM <br />SHIM; REF 4-6/S2.0 FOR <br />STRUCT <br />-CONT SLNT-4 CANT FULL <br />PERIMETER OF ALUM SHIM, TYP <br />SET IN SLNT-4; <br />REF 17/A5.3 FOR <br />SADDLES & <br />TRANSITIONS <br />-(E) OR (N) FRAMING; ADD <br />BLOCKING PER STRUCT <br />WHERE REQ'D <br />-(E) SIDING 0/ 2 <br />LAYERS OF WRB <br />0/ GYPA <br />SID-1 0/ 3/8" PLY <br />FURRING <br />CONT INSECT SCREEN @ <br />BASE OF 3/8" PLY FURRING <br />MEM-1; W/ INTEGRAL <br />I' <br />FF-5, SET IN SLNT-4 <br />a I <br />H III <br />PLY -1 0/ TAPERED <br />I1 <br />I 1 <br />SLEEPERS <br />I ' <br />SLOPE <br />LL <br />`__V�(E) <br />LBLOCK <br />OR (N) FRAMING W/ <br />BLOCKING AS AS <br />(N) TAPERED 2X <br />REQ'D TO INSTALL REQ'D <br />SLEEPERS RIPPED TO <br />MEM-1 <br />SLOPE AS REQ'D <br />MEM-1 @SID-1 <br />NOTE: REF 8C & <br />D/A5.3 FOR SOFFIT. <br />TYPICAL LANDINGS <br />& ELEVATED WALKWAYS - SECTIONS <br />3" = 11 <br />-0" SID_FCP_XX) SE_003 <br />NOTE: REF SHEETS <br />A3.1, A3.2 & 16G/A5.4 <br />6"FOR TYP INSTALLATION. <br />411 I //Fj4•� <br />4" <br />2" <br />DRIP OR STRAIGHT EDGE <br />CLEAT UNDER STRINGER <br />SADDLE @ <br />B BEAM TO WALL TRANSITION <br />NOTE: REF <br />16E/A5.4 FOR TYP <br />HEMMED INSTALLATION. <br />EDGES, TYP <br />4„P 4" TYP <br />VIF <br />2" <br />STRAIGHT <br />41, <br />EA EDGE CLT <br />STRAIGHT 4° VIF 4.. <br />EDGE CLEAT <br />F TOP OF STRINGER @WALL <br />N L/ -- HEMMED <br />STRAIGHT <br />STRAIGHT EDGE EDGE <br />FLASHING @STAIRS 19 <br />U <br />WALKWAY & LANDING <br />FLASHING COMPONENTS - AXONS <br />NO SCALE MEM_MTL_WW_AX_001 I A5.3 NO SCALE MEM_MTL_SD_A)(_001 <br />NOTE: REF 16C & D/A5.4 FOR <br />SIM INSTALLATION. <br />4" <br />Typ <br />2" TYP <br />4" <br />CONT DRIP <br />EDGE CLEAT <br />I INTERIOR CORNER 6 <br />PLY-2 OR (E) PLY <br />GYP-1 OR (E) GYP <br />2 LAYERS OF WRB; LAP <br />W/ (E) WRB <br />(E) SID TO BE RE/RE AS <br />REQ'D TO ACCOM MEM-1 <br />INSTALL OR STRUCT, TYP <br />BLOCKING AS REQ'D <br />TO INSTALL MEM-1 <br />MEM-1; W/ INTEGRAL FF-5, <br />SET IN SLNT-4 <br />PLY-1 0/ TAPERED SLEEPERS <br />SLOPE NOTE: REF 6A/A5.2 <br />FOR SID-1 TO <br />SOFFIT <br />TRANSITIONS. <br />(E) OR (N) FRAMING W/ <br />(N) TAPERED 2X <br />SLEEPERS RIPPED TO <br />SLOPE AS REQ'D <br />_---BLKG AS REQ'D <br />SP-1 0/ --VENT-1; LOCATE 1'-0" <br />GYP-1; FROM FRONT & BACK <br />PNT-6 EDGES; PROVIDE <br />BLKG AS REQ'D TO <br />SUPPORT SOFFIT <br />C WALKWAY @ WALL <br />NOTE: REF 16A/A5.4 <br />FOR INSTALLATION. <br />1 /2" END DAM <br />4,' <br />J� <br />N <br />2" <br />WV VIF <br />DRIP EDGVIF HEMMED STRAIGHT <br />CLEAT EDGES, TYP EDGE CLEAT <br />SADDLE @ TOP OF <br />STRINGER @WALKWAY <br />C <br />DRIP EDGE <br />CLEAT <br />NOTE: REF I AA WAS a <br />FOR SECTIi <br />4" <br />"'�� --HEMMED <br />DRIP EDGE <br />1� DRIP EDGE FLASHING 18 <br />NOTE: REF 16C & D/A5.4 <br />FOR INSTALLATION. <br />4" <br />Typ <br />2" TYP <br />STRAIGHT <br />EDGE CLEAT VHF 4" <br />INTERIOR <br />J CORNER @ STAIRS <� <br />DRIP EDGE <br />CLEAT <br />NOTES: <br />1. REF SECTION 01 10 00 - DESCRIPTION OF THE WORK & SHEET <br />A0.3 FOR FRAMING REPLACEMENT INFO & LOCATIONS. <br />2. REFER TO SHEETS A3.3 & A3.4 FOR ENLARGED ELEVS OF <br />GUARDRAILS @ WALKWAYS & LANDINGS. <br />3. REFER TO SHEETS A5.3 & A5.4 FOR METAL FLASHING <br />COMPONENTS. <br />4. GUARDRAILS VARY; REFER TO SHEETS A3.1 & A3.2 FOR <br />ENLARGED STAIR PLANS. <br />5. REFER TO SHEETS S1.0 & S2.0 FOR STRUCT REQUIREMENTS <br />@ GUARDRAILS. <br />6. REF 16/A5.4 FOR MEM-1 TRANSITIONS & TERMINATIONS @ <br />STAIR STRINGERS. <br />7. ROUT SHEATHING EDGE TO ACCOM MTLS #18, #19 & <br />ASSOCIATED SADDLES. <br />8. INSTALL LIGHT-1 @ ALL (E) SOFFIT LIGHT LOCATIONS, <br />INCLUDING TOP FLOOR W/ (E) SOFFITS TO REMAIN INSTALLED. <br />MEM-1 W/ INTEGRAL 18 SET IN SLNT-4; <br />FF-6, SET IN SLNT-4 REF 17/A5.3 FOR <br />----- -'N SADDLES & <br />- - - - - - - TRANSITIONS <br />1A <br />5.4 <br />OPP <br />PLY-1 0/ TAPERED <br />SLEEPERS; ROUTE <br />EDGE TO ACCOM - - L (E) SIDING 0/ 2 <br />MTL #18 LAYERS OF WRB <br />0/ GYP-1 <br />(E) OR (N) <br />WALKWAY LJ <br />FRAMING ( BOTTOM OF _WALKW_AY <br />FASCIA TO BE LEVEL <br />SP-1 0/ GYP-1; <br />PNT-6 TRIM-3 W/ FILLET <br />SLNT-2; PNT-6 <br />NOTE: VENT-1 NOT SHOWN, <br />COORD W/ ARCH FOR LOCATIONS. <br />NOTE: SOFFIT DETAIL SIM @ BASE OF STAIR <br />STRINGERS; REF 19B/A5.4 FOR FASCIA. <br />TYPICAL WALKWAY/LANDING INTERIOR EDGE <br />4" 4" „Ic NOTE: REF <br />1/A5.3 FOR <br />gSTALLATION. <br />1/2" END DAM <br />SADDLE @ 4)> <br />D WALKWAY BEAM TO (E} SIDING <br />NOTES: <br />1. REFER TO SHEETS A3.1 & A3.2 FOR ENLARGED <br />WALKWAY/LANDING PLANS. <br />2. REF METAL SCHEDULE ON SHEET A0.1 FOR DIMENSIONS & <br />ADD'L FLASHING PARAMETERS. <br />3. PREP DRIP EDGES TO RECEIVE ADJ MTL FLASHING @ FLAT <br />LAPPED SEAMS, WHERE THEY OCCUR; REF 12/A5.1. <br />4. USE DRIP EDGE CLEATS TO SECURE ADJ MTL FLASHINGS. <br />5. REF 16/A5.4 FOR ASSEMBLY CONDITIONS @ ELEVATED <br />WALKWAY/LANDING EDGES. <br />6. INSTALL FLASHINGS IN SEQUENCE NOTED ON ASSEMBLY <br />DETAILS. <br />7. SET ALL SADDLES & FLASHINGS IN SLNT-4 & SEAL MTL LAPPED <br />SEAMS @ MEM-1 W/ SLNT-4. <br />8. FORM MTL FLASHINGS TIGHT TO STRINGERS & SUBSTRATES, <br />TYP. <br />9. HEM ALL EDGES WHERE EXPOSED. <br />AM E NTOG RO U P <br />710 2nd Avenue, Suite 400 <br />Seattle, WA 98104 <br />amentogroup.com <br />9016 REGISTERED <br />ARCHITECT <br />LISA CLARK MOE <br />STATE OF WASHINGTON <br />The documents created by the <br />Architect and its Consultants <br />for this project are instruments <br />of the Architect's service. The <br />Architect retains all common <br />law, statutory and other <br />reserved rights, including the <br />copyright. The Architect's <br />documents shall not be used <br />by anyone on any other <br />project, except with the <br />Architect's written permission. <br />GREENS OF <br />MERRILL CREEK <br />APARTMENTS <br />3 <br />Br_t <br />1707 MERRILL CREEK PKWY <br />EVERETT, WA 98203 <br />STAIR <br />REMEDIATION <br />WATERPROOFING & <br />FLASHING DETAILS <br />PERMIT SET <br />PROJECT M <br />070042 <br />DRAWN BY: <br />AJL, DGS, HLS <br />CHECKED BY: <br />MFV, MNM <br />REVISIONS: <br />10-16-2020 PERMIT SET <br />BLDG DEPT: <br />DATE: <br />10-16-2020 <br />SHEET TITLE: <br />TYP ELEVATED <br />WALKWAY/ <br />LANDING DETAILS <br />BUILDING TYPE: <br />N/A <br />SHEET #: <br />A503 <br />