Laserfiche WebLink
FLASHING <br />SOLDERED <br />VERT <br />HORIZ <br />VERT <br />SIDE OR <br />MOCKUP <br />TYPEO <br />DESCRIPTION <br />DETAIL REFERENCES <br />ONE-PIECE <br />FINISH <br />FLANGE <br />FLANGE <br />DRIP <br />RETURN <br />REQUIREMENTS <br />COMMENTS <br />FLANGE <br />FLANGES <br />HEAD <br />1 <br />HEAD FLASHING @ MISC PENETRATIONS <br />16A/A5.2; 6D/A5.5 <br />NO <br />MTL-1 <br />4" <br />VIE <br />314" <br />_ <br />REQ'D <br />W/ HEMMED DRIP EDGE & 1/2" END DAMS, SET IN SLNT-2 <br />FLASHINGS <br />OR <br />MTL-3 <br />2 <br />"L " BASE METAL FLASHING @ <br />9A,12/A5.1; 17/A5.2; <br />No <br />MTL-4 <br />6" <br />1 1/2" / <br />REQ'D <br />W/ HEMMED EDGE; PROVIDE SADDLES #6, 7, 8, 9, 10 11 & 12; SET IN <br />HARDSCAPE & BRICK <br />6B/A5.3 <br />OR <br />VIF <br />SLNT-3 <br />MTL-5 <br />3 <br />STRAIGHT BASE METAL FLASHING <br />9B/A5.1 <br />NO <br />MTL-4 <br />5" <br />_ <br />W1 STRAIGHT HEM; SET IN SLNT-3 <br />4 <br />"L" BASE METAL FLASHING @ GRADE <br />9C/A5.1 <br />NO <br />MTL-4 <br />4" <br />VIF / <br />- <br />- <br />- <br />W/O HEMMED EDGE; PROVIDE IN CONJUNCTION W/ MTL WHERE <br />VARIES <br />GRADE IS MORE THAN 6" FROM BASE OF SIDING; SHAPE PER DETAIL <br />TO ACCOM MTL #5 <br />"Z" BASE METAL FLASHING GRADE <br />9D/A5.1 <br />NO <br />MTL-4 <br />4" <br />VIE <br />1" <br />- <br />- <br />SHAPE PER DETAIL; W/ HEMMED EDGE; SET IN SLNT-3 <br />6 <br />#2 INT CORNER SADDLE <br />8A,17/A5.2 <br />YES <br />MTL-2 <br />611 <br />1 1/2" / <br />- <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED <br />VIF <br />EDGES <br />7 <br />#2 EXT CORNER SADDLE <br />8B,17/A5.2 <br />YES <br />MTL-2 <br />611 <br />1 1/2" / <br />- <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL TO ACCOM MTL # 2 <br />SIDING, <br />VIF <br />BASE & <br />8 <br />#2 SADDLE @ HARDSCAPE TRANSITIONS <br />8C1A5.2 <br />YES <br />MTL-2 <br />6" <br />VIF / <br />4" <br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED <br />TRANSITION <br />VARIES <br />EDGES <br />FLASHINGS <br />9 <br />#2 SADDLE @G DE TO HARDSCAPE <br />8D/A5.2 <br />YES <br />MTL-2 <br />6'" <br />VIF / <br />VIF <br />4" <br />- <br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED <br />TRANSITION <br />VARIES <br />EDGES <br />10 <br />BRICK CAP SADDLE <br />8E,10/A5.2 <br />YES <br />MTL-2 <br />6" <br />VIF <br />2" <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL TO ACCOM (E) BRICK & METAL, W/ 1/2" END DAM <br />& HEMMED EXPOSED EDGES <br />11 <br />NOT USED <br />- <br />_ <br />_ <br />- <br />- <br />_ <br />12 <br />NOT USED <br />- <br />- <br />- <br />- <br />- <br />o <br />m <br />e <br />13 <br />"J" METAL @ SID-1 TO CONC <br />6A/A5.1 <br />NO <br />MTL-4 <br />- <br />61" <br />- <br />- <br />- <br />SHAPE PER DETAIL W1 HEMMED EDGE <br />14 <br />SID-1 THROUGH WALL FLASHING <br />13A,17A,B,C,D/A5.1 <br />NO <br />MTL-1 <br />6" <br />VIF <br />2" <br />- <br />REQ'D <br />SHAPE PER DETAIL W/ HEMMED DRIP EDGE <br />15 <br />#14 EXT CORNER SADDLE <br />13B,17A,CIA5.1 <br />YES <br />MTL-2 <br />6" <br />VIF <br />2" <br />- <br />REQ'D <br />SHAPE PER DETAIL W/ DRIP EDGE CLEAT <br />16 <br />#14 END CAP SADDLE <br />13C,17B/A5.1 <br />YES <br />MTL-2 <br />' <br />61 <br />VIF <br />2" <br />- <br />REQ'D <br />SHAPE PER DETAIL W/ DRIP EDGE CLEAT <br />17 <br />NOT USE® <br />- <br />a <br />- <br />- <br />- <br />- <br />- <br />18 <br />WALKWAY& LANDING DRIP EDGE <br />8A,D,17G/A5.3, <br />NO <br />MTL-1 <br />- <br />4" <br />2" <br />- <br />RECOMMENDED <br />W/ HEMMED DRIP EDGE; PROVIDE SADDLES @ CORNERS, <br />FLASHING <br />1A,1B,16A,B,C,D,E/A5.4 <br />TRANSITIONS & TERMINATIONS <br />19 <br />HEMMED EDGE FLASHING @ STAID <br />17H/A5.3; <br />NO <br />MTL-1 <br />- <br />4" <br />2" <br />- <br />RECOMMENDED <br />W/ STRAIGHT HEM; PROVIDE SADDLES @ CORNERS, TRANSITIONS & <br />TREADS <br />1C,16,19B,C/A5.4 <br />TERMINATIONS <br />20 <br />#14 TO #18 SADDLE @ WALL <br />16,17A/A5.3 <br />YES <br />MTL-2 <br />' <br />61 <br />4" <br />2" <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT <br />21 <br />#18 OR #19 SADDLE @ BEAM TO WALL <br />17B/A5.3; 16G/A5.4 <br />YES <br />MTL-2 <br />6" <br />4" / VIF <br />2" <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL, W/ DRIP EDGE CLEAT @ MTL #18 OR STRAIGHT <br />EDGE CLEAT @ MTL #19-1 SIDE HORN FLANGE TO EXTEND BELOW & <br />4" PAST STRINGER (WHERE OCCURS) TO LAP W/ADJ EDGE <br />WALKWAY & <br />FLASHING <br />LANDING <br />22 <br />#18 & #19 SADDLE @ TOP OF STRINGER <br />17C/A5.3; 16A/A5.4; <br />YES <br />MTL-2 <br />- <br />4" / VIF <br />2" <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL; PROVIDE END DAM; W/ DRIP EDGE CLEAT & <br />FLASHINGS <br />19A/A5.5 <br />STRAIGHTEDGE CLEAT; HEMMED EXPOSED EDGES <br />23 <br />#18 SADDLE @ BEAM TO PLANAR WALL <br />11,17D/A5.3 <br />YES <br />MTL-2 <br />6" <br />4" <br />/" <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT <br />24 <br />#18 & #19 SADDLE @ TOP OF STRINGER <br />17E/A5.3; 16B/A5.4 <br />YES <br />MTL-2 <br />- <br />4" / VIF <br />9" <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL; W1 DRIP EDGE CI EAT & STRAIGHTEDGE CLEAT; <br />HEMMED EXPOSED EDGES <br />25 <br />#18 & #19 SADDLE @ TOP OF STRINGER <br />17F/A5.3; 16EIA5.4; <br />YES <br />MTL_-2 <br />4" / VIF <br />2 <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHTEDGE CLEAT; <br />19B/A5.5 <br />HEMMED EXPOSED EDGES <br />26 <br />#18 INT CORNER SADDLE <br />17VA5.3 <br />YES <br />MTL-2 <br />- <br />4" <br />2" <br />41" <br />RECOMMENDED <br />SHAPE PER DETAIL; W1 DRIP EDGE CLEATS <br />27 <br />#18 & #19 INT CORNER SADDLE <br />17J/A5.3; <br />YES <br />MTL-2 <br />- <br />4" <br />2" <br />4" <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHT EDGE CLEAT, <br />16C,D,19A/A5.4 <br />S17-E HORIZ FLANGE TO EXTEND BELOW & 4" PAST STRINGER <br />(WHERE OCCURS) TO LAP W/ADJ EDGE FLASHING <br />M1 <br />28 <br />STRINGER CAP FLASHING <br />4/A5.4;19B/A5.5 <br />NO <br />MTL-1 <br />6" <br />VIF <br />VIF <br />- <br />RECOMMENDED <br />SHAPE PER DETAIL; W/ HEMMED EDGE & END DAM @ BOTTOM OF <br />FLASHINGS <br />STRINGER; PROPERLY LAP W/ MTL #25 TOP OF STRINGER; <br />PROVIDE BLOCKING @ HANDRAIL ATTACHMENT LOCATIONS <br />ri--� <br />A0.1 <br />JUmaxwo <br />v 4: <br />SCHEDULE1. REFER TO METAL FLASHING SCHEDULE ON 1/A0.1 &METAL FLASHING <br />NOTES O A <br />INSTALL2. <br />RECOMMENDATIONS. <br />6. FIELD VERIFY ALL FLASHING <br />FIT TIGHT x. TRUE TO SUBSTRATE, <br />7. ALL METAL FLASHING IS TO HAVE MINIMUM 4" FLAT SEAM OVERLAPS, UNO. <br />FULLY SEAL PER SPECIFICATIONS. PROVIDE FLAT SEAM OVERLAPS <br />BACKERPLATES ALL LOCATIONS. <br />12. FINISHED METAL FLASHINGS SHALL BE AESTHETICALLY PLEASING, ALIGN, <br />FORM TIGHT SEAMS & MEET REQUIREMENTS_ 07 60 1 <br />FLASHING .i.: SHEET METAL. <br />ri-� <br />A0.1 <br />L� t <br />DESCRIPTIONS2. R TITLES OF METAL FLASHING SCHEDULE A NOT <br />EXACTLY MATCH FLASHING DESCRIPTION IN DETAILS. METAL <br />FLASHING NUMBER IS INDICATOR OF SCHEDULED FLASHING @ EACH <br />3. DETAIL I -- - _ COLUMN IN SCHEDULEOR REFERENCE <br />A COMPLETE LIST <br />OF <br />ALL i WATERPROOFING <br />D' TL _-. <br />4. FLASHING -SCHEDULE, LINO IN <br />DETAILS. IF DISCREPANCIES ARISE, CONTACT ARCH FOR DIRECTION s <br />9. PROVIDE A DRIP EDGE CLEAT @ ALL SADDLES AS NOTED IN THE <br />COMMENTS SECTION OF THE SCHEDULE. A DRIP EDGE CLEAT IS A <br />DRIP EDGEHEM. <br />10. ALL HEMMED DRIP EDGES SHALL BE CLOSED& CONTINUOUS AROUND <br />VERTICAL <br />11. DRIPFLANGE NOTED DEFINE <br />VERTICAL FLANGE W/O HEMMED DRIP OR HEMMED FLANGE; HEMMED <br />Dr OR <br />HEMMED FLANGE ARE IN ADDITIONVERTICAL FLANGE <br />DIMENSION. <br />- RX01 0 W4 I <br />13. - FOR -AIGHT SEAM LAPBACKER <br />EXPANSION JOINT METAL. THIS DETAIL APPLIES AS THE CONCEPT FO <br />ALL OTHER METAL FLAT SEAM LAP JOINTS. PROVIDE BACKER PLATE <br />@ ALL STRAIGHT SEAM LAP JOINTS @ ALL METAL. <br />14. CLEATS SHALL BE 24 GAUGE. PROVIDE CLEATS CONTINUOUSLY <br />ALONG LENGTH OF FLASHINGS. <br />15. MOCK-UPS: PROVIDE MOCK-UPS AS REQUIRED BY SCHEDULE. SOME <br />MOCK-UPS ARE RECOMMENDED FOR REVIEW BY ARCH, WHICH ARE T* <br />BE PROVIDED @ THE CONTRACTOR'S DISCRETION. FLASHING$ SHALL <br />BE REVIEWED BY ARCH ON SITE FOR DESIGN INTENT & <br />COORDINATION. <br />9016 REGISTERED <br />ARCHITECT <br />I <br />r) 1,(, <br />LI' CLARK MOE <br />STATE OF WASHINGTON <br />createdThe documents <br />Architect and its Consultants <br />for this project are instruments <br />of the Architect's service. The <br />Architect retains all common <br />law, statutory and other <br />reserved rights, including ., <br />copyright. TheArchitect's <br />documents shall not , <br />e used <br />by anyone on any other <br />pArchitect's written permission. <br />roject, <br />w <br />PROJECT #: <br />DRAWN BY: <br />AJL <br />HLS <br />3 9 <br />CHECKED BY: <br />11� <br />REVISIONS: <br />10-16-2020 PERMIT SET <br />BLDG DEPT: <br />DATE: <br />m <br />16-2020 <br />SHEET TITLE: <br />BUILDING TYPE: <br />