FLASHING
<br />SOLDERED
<br />VERT
<br />HORIZ
<br />VERT
<br />SIDE OR
<br />MOCKUP
<br />TYPEO
<br />DESCRIPTION
<br />DETAIL REFERENCES
<br />ONE-PIECE
<br />FINISH
<br />FLANGE
<br />FLANGE
<br />DRIP
<br />RETURN
<br />REQUIREMENTS
<br />COMMENTS
<br />FLANGE
<br />FLANGES
<br />HEAD
<br />1
<br />HEAD FLASHING @ MISC PENETRATIONS
<br />16A/A5.2; 6D/A5.5
<br />NO
<br />MTL-1
<br />4"
<br />VIE
<br />314"
<br />_
<br />REQ'D
<br />W/ HEMMED DRIP EDGE & 1/2" END DAMS, SET IN SLNT-2
<br />FLASHINGS
<br />OR
<br />MTL-3
<br />2
<br />"L " BASE METAL FLASHING @
<br />9A,12/A5.1; 17/A5.2;
<br />No
<br />MTL-4
<br />6"
<br />1 1/2" /
<br />REQ'D
<br />W/ HEMMED EDGE; PROVIDE SADDLES #6, 7, 8, 9, 10 11 & 12; SET IN
<br />HARDSCAPE & BRICK
<br />6B/A5.3
<br />OR
<br />VIF
<br />SLNT-3
<br />MTL-5
<br />3
<br />STRAIGHT BASE METAL FLASHING
<br />9B/A5.1
<br />NO
<br />MTL-4
<br />5"
<br />_
<br />W1 STRAIGHT HEM; SET IN SLNT-3
<br />4
<br />"L" BASE METAL FLASHING @ GRADE
<br />9C/A5.1
<br />NO
<br />MTL-4
<br />4"
<br />VIF /
<br />-
<br />-
<br />-
<br />W/O HEMMED EDGE; PROVIDE IN CONJUNCTION W/ MTL WHERE
<br />VARIES
<br />GRADE IS MORE THAN 6" FROM BASE OF SIDING; SHAPE PER DETAIL
<br />TO ACCOM MTL #5
<br />"Z" BASE METAL FLASHING GRADE
<br />9D/A5.1
<br />NO
<br />MTL-4
<br />4"
<br />VIE
<br />1"
<br />-
<br />-
<br />SHAPE PER DETAIL; W/ HEMMED EDGE; SET IN SLNT-3
<br />6
<br />#2 INT CORNER SADDLE
<br />8A,17/A5.2
<br />YES
<br />MTL-2
<br />611
<br />1 1/2" /
<br />-
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED
<br />VIF
<br />EDGES
<br />7
<br />#2 EXT CORNER SADDLE
<br />8B,17/A5.2
<br />YES
<br />MTL-2
<br />611
<br />1 1/2" /
<br />-
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL TO ACCOM MTL # 2
<br />SIDING,
<br />VIF
<br />BASE &
<br />8
<br />#2 SADDLE @ HARDSCAPE TRANSITIONS
<br />8C1A5.2
<br />YES
<br />MTL-2
<br />6"
<br />VIF /
<br />4"
<br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED
<br />TRANSITION
<br />VARIES
<br />EDGES
<br />FLASHINGS
<br />9
<br />#2 SADDLE @G DE TO HARDSCAPE
<br />8D/A5.2
<br />YES
<br />MTL-2
<br />6'"
<br />VIF /
<br />VIF
<br />4"
<br />-
<br />SHAPE PER DETAIL TO ACCOM MTL # 2; W/ HEMMED EXPOSED
<br />TRANSITION
<br />VARIES
<br />EDGES
<br />10
<br />BRICK CAP SADDLE
<br />8E,10/A5.2
<br />YES
<br />MTL-2
<br />6"
<br />VIF
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL TO ACCOM (E) BRICK & METAL, W/ 1/2" END DAM
<br />& HEMMED EXPOSED EDGES
<br />11
<br />NOT USED
<br />-
<br />_
<br />_
<br />-
<br />-
<br />_
<br />12
<br />NOT USED
<br />-
<br />-
<br />-
<br />-
<br />-
<br />o
<br />m
<br />e
<br />13
<br />"J" METAL @ SID-1 TO CONC
<br />6A/A5.1
<br />NO
<br />MTL-4
<br />-
<br />61"
<br />-
<br />-
<br />-
<br />SHAPE PER DETAIL W1 HEMMED EDGE
<br />14
<br />SID-1 THROUGH WALL FLASHING
<br />13A,17A,B,C,D/A5.1
<br />NO
<br />MTL-1
<br />6"
<br />VIF
<br />2"
<br />-
<br />REQ'D
<br />SHAPE PER DETAIL W/ HEMMED DRIP EDGE
<br />15
<br />#14 EXT CORNER SADDLE
<br />13B,17A,CIA5.1
<br />YES
<br />MTL-2
<br />6"
<br />VIF
<br />2"
<br />-
<br />REQ'D
<br />SHAPE PER DETAIL W/ DRIP EDGE CLEAT
<br />16
<br />#14 END CAP SADDLE
<br />13C,17B/A5.1
<br />YES
<br />MTL-2
<br />'
<br />61
<br />VIF
<br />2"
<br />-
<br />REQ'D
<br />SHAPE PER DETAIL W/ DRIP EDGE CLEAT
<br />17
<br />NOT USE®
<br />-
<br />a
<br />-
<br />-
<br />-
<br />-
<br />-
<br />18
<br />WALKWAY& LANDING DRIP EDGE
<br />8A,D,17G/A5.3,
<br />NO
<br />MTL-1
<br />-
<br />4"
<br />2"
<br />-
<br />RECOMMENDED
<br />W/ HEMMED DRIP EDGE; PROVIDE SADDLES @ CORNERS,
<br />FLASHING
<br />1A,1B,16A,B,C,D,E/A5.4
<br />TRANSITIONS & TERMINATIONS
<br />19
<br />HEMMED EDGE FLASHING @ STAID
<br />17H/A5.3;
<br />NO
<br />MTL-1
<br />-
<br />4"
<br />2"
<br />-
<br />RECOMMENDED
<br />W/ STRAIGHT HEM; PROVIDE SADDLES @ CORNERS, TRANSITIONS &
<br />TREADS
<br />1C,16,19B,C/A5.4
<br />TERMINATIONS
<br />20
<br />#14 TO #18 SADDLE @ WALL
<br />16,17A/A5.3
<br />YES
<br />MTL-2
<br />'
<br />61
<br />4"
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT
<br />21
<br />#18 OR #19 SADDLE @ BEAM TO WALL
<br />17B/A5.3; 16G/A5.4
<br />YES
<br />MTL-2
<br />6"
<br />4" / VIF
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL, W/ DRIP EDGE CLEAT @ MTL #18 OR STRAIGHT
<br />EDGE CLEAT @ MTL #19-1 SIDE HORN FLANGE TO EXTEND BELOW &
<br />4" PAST STRINGER (WHERE OCCURS) TO LAP W/ADJ EDGE
<br />WALKWAY &
<br />FLASHING
<br />LANDING
<br />22
<br />#18 & #19 SADDLE @ TOP OF STRINGER
<br />17C/A5.3; 16A/A5.4;
<br />YES
<br />MTL-2
<br />-
<br />4" / VIF
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; PROVIDE END DAM; W/ DRIP EDGE CLEAT &
<br />FLASHINGS
<br />19A/A5.5
<br />STRAIGHTEDGE CLEAT; HEMMED EXPOSED EDGES
<br />23
<br />#18 SADDLE @ BEAM TO PLANAR WALL
<br />11,17D/A5.3
<br />YES
<br />MTL-2
<br />6"
<br />4"
<br />/"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT
<br />24
<br />#18 & #19 SADDLE @ TOP OF STRINGER
<br />17E/A5.3; 16B/A5.4
<br />YES
<br />MTL-2
<br />-
<br />4" / VIF
<br />9"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W1 DRIP EDGE CI EAT & STRAIGHTEDGE CLEAT;
<br />HEMMED EXPOSED EDGES
<br />25
<br />#18 & #19 SADDLE @ TOP OF STRINGER
<br />17F/A5.3; 16EIA5.4;
<br />YES
<br />MTL_-2
<br />4" / VIF
<br />2
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHTEDGE CLEAT;
<br />19B/A5.5
<br />HEMMED EXPOSED EDGES
<br />26
<br />#18 INT CORNER SADDLE
<br />17VA5.3
<br />YES
<br />MTL-2
<br />-
<br />4"
<br />2"
<br />41"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W1 DRIP EDGE CLEATS
<br />27
<br />#18 & #19 INT CORNER SADDLE
<br />17J/A5.3;
<br />YES
<br />MTL-2
<br />-
<br />4"
<br />2"
<br />4"
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ DRIP EDGE CLEAT & STRAIGHT EDGE CLEAT,
<br />16C,D,19A/A5.4
<br />S17-E HORIZ FLANGE TO EXTEND BELOW & 4" PAST STRINGER
<br />(WHERE OCCURS) TO LAP W/ADJ EDGE FLASHING
<br />M1
<br />28
<br />STRINGER CAP FLASHING
<br />4/A5.4;19B/A5.5
<br />NO
<br />MTL-1
<br />6"
<br />VIF
<br />VIF
<br />-
<br />RECOMMENDED
<br />SHAPE PER DETAIL; W/ HEMMED EDGE & END DAM @ BOTTOM OF
<br />FLASHINGS
<br />STRINGER; PROPERLY LAP W/ MTL #25 TOP OF STRINGER;
<br />PROVIDE BLOCKING @ HANDRAIL ATTACHMENT LOCATIONS
<br />ri--�
<br />A0.1
<br />JUmaxwo
<br />v 4:
<br />SCHEDULE1. REFER TO METAL FLASHING SCHEDULE ON 1/A0.1 &METAL FLASHING
<br />NOTES O A
<br />INSTALL2.
<br />RECOMMENDATIONS.
<br />6. FIELD VERIFY ALL FLASHING
<br />FIT TIGHT x. TRUE TO SUBSTRATE,
<br />7. ALL METAL FLASHING IS TO HAVE MINIMUM 4" FLAT SEAM OVERLAPS, UNO.
<br />FULLY SEAL PER SPECIFICATIONS. PROVIDE FLAT SEAM OVERLAPS
<br />BACKERPLATES ALL LOCATIONS.
<br />12. FINISHED METAL FLASHINGS SHALL BE AESTHETICALLY PLEASING, ALIGN,
<br />FORM TIGHT SEAMS & MEET REQUIREMENTS_ 07 60 1
<br />FLASHING .i.: SHEET METAL.
<br />ri-�
<br />A0.1
<br />L� t
<br />DESCRIPTIONS2. R TITLES OF METAL FLASHING SCHEDULE A NOT
<br />EXACTLY MATCH FLASHING DESCRIPTION IN DETAILS. METAL
<br />FLASHING NUMBER IS INDICATOR OF SCHEDULED FLASHING @ EACH
<br />3. DETAIL I -- - _ COLUMN IN SCHEDULEOR REFERENCE
<br />A COMPLETE LIST
<br />OF
<br />ALL i WATERPROOFING
<br />D' TL _-.
<br />4. FLASHING -SCHEDULE, LINO IN
<br />DETAILS. IF DISCREPANCIES ARISE, CONTACT ARCH FOR DIRECTION s
<br />9. PROVIDE A DRIP EDGE CLEAT @ ALL SADDLES AS NOTED IN THE
<br />COMMENTS SECTION OF THE SCHEDULE. A DRIP EDGE CLEAT IS A
<br />DRIP EDGEHEM.
<br />10. ALL HEMMED DRIP EDGES SHALL BE CLOSED& CONTINUOUS AROUND
<br />VERTICAL
<br />11. DRIPFLANGE NOTED DEFINE
<br />VERTICAL FLANGE W/O HEMMED DRIP OR HEMMED FLANGE; HEMMED
<br />Dr OR
<br />HEMMED FLANGE ARE IN ADDITIONVERTICAL FLANGE
<br />DIMENSION.
<br />- RX01 0 W4 I
<br />13. - FOR -AIGHT SEAM LAPBACKER
<br />EXPANSION JOINT METAL. THIS DETAIL APPLIES AS THE CONCEPT FO
<br />ALL OTHER METAL FLAT SEAM LAP JOINTS. PROVIDE BACKER PLATE
<br />@ ALL STRAIGHT SEAM LAP JOINTS @ ALL METAL.
<br />14. CLEATS SHALL BE 24 GAUGE. PROVIDE CLEATS CONTINUOUSLY
<br />ALONG LENGTH OF FLASHINGS.
<br />15. MOCK-UPS: PROVIDE MOCK-UPS AS REQUIRED BY SCHEDULE. SOME
<br />MOCK-UPS ARE RECOMMENDED FOR REVIEW BY ARCH, WHICH ARE T*
<br />BE PROVIDED @ THE CONTRACTOR'S DISCRETION. FLASHING$ SHALL
<br />BE REVIEWED BY ARCH ON SITE FOR DESIGN INTENT &
<br />COORDINATION.
<br />9016 REGISTERED
<br />ARCHITECT
<br />I
<br />r) 1,(,
<br />LI' CLARK MOE
<br />STATE OF WASHINGTON
<br />createdThe documents
<br />Architect and its Consultants
<br />for this project are instruments
<br />of the Architect's service. The
<br />Architect retains all common
<br />law, statutory and other
<br />reserved rights, including .,
<br />copyright. TheArchitect's
<br />documents shall not ,
<br />e used
<br />by anyone on any other
<br />pArchitect's written permission.
<br />roject,
<br />w
<br />PROJECT #:
<br />DRAWN BY:
<br />AJL
<br />HLS
<br />3 9
<br />CHECKED BY:
<br />11�
<br />REVISIONS:
<br />10-16-2020 PERMIT SET
<br />BLDG DEPT:
<br />DATE:
<br />m
<br />16-2020
<br />SHEET TITLE:
<br />BUILDING TYPE:
<br />
|