Laserfiche WebLink
SCOPE OF WORK GOVERNING CODES SYSTEM RATING PHOTOVOLTAIC SYSTEM FIRE <br /> TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE CLASSIFICATION LISTING IN 600 kVVDC 3. Lumio <br /> LOCATED AT 2508 CLEVELAND AVE, EVERETT, WA 98201, USA. 2018 INTERNATIONAL FIRE CODE ACCORDANCE WITH UL 1703 <br /> THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY 2018 INTERNATIONAL BUILDING CODE 2.700 kWAC STANDARD. <br /> GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. 2018 INTERNATIONAL RESIDENTIAL CODE SMART ENERGY TODAY <br /> THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. 2020 NATIONAL ELECTRICAL CODE SHEET INDEX 1550 DIGITAL DR,LEHI,UT <br /> WASHINGTON ADMINISTRATIVE CODE (WAC) PV1 COVER PAGE 84043,USA <br /> EQUIPMENT SUMMARY AHJ NAME : CITY OF EVERETT PV2 SITE PLAN <br /> 9 Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES WIRING AND CONDUIT NOTES PV3 ROOF PLAN <br /> 9 ENPHASE IQ8PLUS-72-2-US (240V) MICROINVERTERS • ALL CONDUIT SIZES AND TYPES SHALL BE LISTED FOR ITS PURPOSE AND PV4 STRING LAYOUT&BOM <br /> APPROVAL FOR THE SITE APPLICATIONS <br /> GENERAL NOTES - ALL <br /> ATTACHMENT DETAILS <br /> CABLING <br /> • THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND ALL PV CABLES AND WIRES BE#1 ,USE 2, PV WIRE, OR PV7 ELECTRICAL LINE&CALCS. <br /> OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE PROPRIETARY SOLAR CABLING SPECIFIED BYYAWG MFR, OR EQUIVALENT; ROUTED TO SYSTEM INFO <br /> MODIFICATIONS IN CONSTRUCTION DETAILS. SOURCE CIRCUIT COMBINER BOXES AS REQUIRED PV8 SPECIFICATIONS&NOTES <br /> (9)Q CELLS <br /> • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE PV9-PV10 SIGNAGE Q.PEAK DUO BILK ML-G10+ <br /> • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR DERATED ACCORDING TO AS PER LATEST NEC CODE. (40OW) <br /> INSTALLATION OF ANY EQUIPMENT AT SITE. PV11 JOB SAFETY PLAN <br /> PHASE <br /> EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90'C RATED, WET AND UV (9)E 2-2-US <br /> • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE PV12-PV21 EQUIPMENT SPECIFICATIONS QBSTEMUS SI-2-US(0 kW <br /> PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. USED TO PROTECT WIRE FROM SHARP EDGES DC SYSTEM SIZE:3.600 kWDC <br /> • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 PROJECT SITE AC SYSTEM SIZE:2.700 kWAC <br /> AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER INSULATED, 90°C RATED, WET AND UV RESISTANT, RATED FOR 1000V AS PER <br /> BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND APPLICABLE NEC <br /> ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE • ' '" •'- " . <br /> CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER �, REVISIONS <br /> COMPENSATION. VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE �{ <br /> DESCRIPTION DATE REV <br /> • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, MEANS /-..� 1 DATEA <br /> ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTIONREVISION 1 22 <br /> • <br /> CONTRACTOR AT NO ADDITIONAL COST. - VOLTAGE DROP LIMITED TO 2% 51 <br /> • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND . AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, .i^+ N <br /> COMPLETION OF THE WORK WITH APPROVED MATERIALS. PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL-WHITE/GRAY <br /> • NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE • VOLTAGE DROP LIMITED TO 2% ,� PROJECT NAME&ADDRESS <br /> ARCHITECT. <br /> • CONTRACTOR SHALL OBTAIN BOLDING PERMIT. NO WORK TO START UNLESS BUILDING • AC CONDUCTORS>4AWG COLOR CODED OR MARKED: PHASE AOR L1-BLACK, <br /> PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL-WHITE/GRAY U) <br /> PERMIT IS PROPERLY DISPLAYED. HOUSE PHOTO SCALE:NTS D <br /> • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE PROJECT SITE p <br /> WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, THE DEPARTMENT OF N <br /> ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. 00 <br /> rn <br /> • IT 1 S ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL Q <br /> PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. eE' o <br /> THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. <br /> • ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO m W o <br /> BE PAINTED BY GENERAL CONTRACTOR. > U LLJ � <br /> 00 <br /> • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THEa z W LO <br /> LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. a U) W > (D <br /> LLJ <br /> • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, N �`o z 0 W LO <br /> LO <br /> ETC.AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. I V E R S I D E © 00 W > o <br /> • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. O Q <br /> O 0 Z <br /> ELECTRICAL NOTES Q 0_ <br /> • ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. <br /> LLI <br /> • ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET - :�-� ,O`�,\�,�Q- W <br /> ENVIRONMENT. S��O\ <br /> • WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY U_J <br /> TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. Home 2 CD <br /> • WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL ot ,ale CV <br /> rG, <br /> COMPLY WITH NEC 110.26. V Mr, l_ ,;a Terms of Use Report a niap error <br /> • WHERE SIZES OF JUNCTION BOXES, RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, THE E DATE: 11/19/2022 <br /> CONTRACTOR SHALL SIZE THEM ACCORDINGLY. VICINITY MAP SCALE:NTS <br /> SHEET NAME <br /> • ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. <br /> • MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE COVER PAGE <br /> SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURERS INSTRUCTION. <br /> • MODULE SUPPORT RAIL SHALL BE BONDED TO THE MODULE SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> __] <br /> PV-1 <br />