My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1301 RUCKER AVE 2023-01-09
>
Address Records
>
RUCKER AVE
>
1301
>
1301 RUCKER AVE 2023-01-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2023 9:33:33 AM
Creation date
1/18/2023 4:04:11 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
1301
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
37 Silfab-380BK modules, 37 Enphase I07-Plus micro inverters NOTES: <br /> 14.06kw DC — 10,73OWMax continuuous AC Output 1.ALL AC PV MODULES SHALL BE CONNECTED WITH MANUFACTURER SUPPLIED CONNECTORS. <br /> 2. INVERTER BRANCH CIRCUIT TRANSITION BOX SHALL BE LOCATED ON THE ROOF AND NEMA 3R <br /> 4 branch circuits 11, 11, 9, 6: SYSTEM INCLUDES RAPID RATED. <br /> Silfab-380 SHUTDOWN AND REQUIRED 3.ALL WIRES FROM ROOF TRANSITION BOX TO AC COMBINER PANEL SHALL BE 10AWG.THWN-2 AND <br /> IN CONDUIT TO MEET NEC CODE AND LIMIT VOLTAGE DROP TO LESS THAN 2%. <br /> Modules MARKING/ LABELING. RAPID SHUTDOWN 4.WIRING IN DC CIRCUITS TO BE RATED 60OV-90C,EXPOSED CABLES SUNLIGHT RESISTANT. <br /> &IQ7+micro- LABELING PER IS INITIATED BY LOSS OF 5.PV SYSTEM Voc SHALL NEVER EXCEED 600 VDC. <br /> inverters UTILITY POWER. 6•Customer Owned PRODUCTION METER&PV SYSTEM DISCONNECT SHALL BE LOCATED NEXT TO <br /> NEC 690/705 NET-METER. <br /> 7,PV MODULE,AND RACKING GROUNDING CONDUCTOR SHALL BE 10AWG,(6awg where exposed to <br /> physical damage). <br /> Customer Owned - L 200 amp service <br /> Production METER <br /> Enphase <br /> Meter#: 353271 IQ7PIus <br /> I I I <br /> Micro-inverter <br /> See ( Downsize Neutral per L1 L2 ` <br /> detail NEC 705.28 (C )(2) Module DC input <br /> at right I I I 1 2@ 46, <br /> 2 @#8 Gnd, L1 L2 120/240 VAC 110 <br /> I I ! THWN-2 copper N FROM UTILITY <br /> N M 3 @#3 -a- <br /> r. <br /> #8 Grid, <br /> X� 1 f t I t 60 amp utility THWN-2 copper <br /> AC disconnect ) 2 A L L <br /> (Inter-locking, } H M 3 @#8, Inverter AC output <br /> I I I I visible break V 290w continuous <br /> I I ) 60A r #10 Gnd, AC output/1.45A <br /> Downsize Neutral per P Service THWN-2 copper <br /> I ( NEC 705.28 (C )(2) Dic connect <br /> I I 2 @#6, 100 <br /> 2 @#8 Gnd, a o 0 <br /> THWN-2 copper z 01 Q <br /> l 24a VAC 10 w o N n �' <br /> 60HZ, Customer <br /> I I I I 45AAC{maX) 3 ` 50a supplied <br /> '10,730Wmp N o `E <br /> 1 1 o G o Charger <br /> NX <br /> SubPanel in <br /> Production T <br /> 1 (i 1 ' �; , I#12AWG Factory10AWG N Gaw Bare Cu garage by <br /> b JVfssembled TCER THWN-2 I sunergy {(<>))� <br /> 3 <br /> L t i L t L j L <br /> Router <br /> I I t t I t 2F7i_1 11 <br /> t I t ! 1 <br /> t t I I a; Internet via WiFi in <br /> it I I I t I t m Consumption CT's customer router <br /> 0. Wi-FI <br /> .� .f .� -� �� E _--_._._-_,_.._.._.._.._._ .-.._.._.._.._.. ._,._._._ ._.._.._ _._ <br /> 7 G Wi-Fi Internet via Utility District: PROPERTY OF Sunergy <br /> WiFi in customer SnoPUD Systems <br /> &awg,Bare Cu 4546 Leary Way NW <br /> MODULE EQUIPMENT GROUND EQUIPMENT GROUND to router Jurisdiction: Cooper <br /> NEMA 3R 125amp Enphase Seattle,WA 98107 <br /> —UL listed/NEC compliant, roof junction box. roof junction IQ ac Everett Project: <br /> SunModo Ground system box Combiner panel: Drawn By: 14.06kW Silfab-En Kase Photovoltaics stem <br /> Jon Lange,NABCEP SiteAddtess: Title/Part/Descrition: <br /> .6%(1_47v)Voltage Drop.,Circuit 1-(290w'11)1240v=13A,@ 240v @ 25ft @ 50c Electrical Engineer: 1301 Rucker Ave <br /> 1.47V=2.0 x 2 x 25.011000x 15.7 x 0.919(DROP=IMPEDANCE per K_LENGTH x2 x LENGTH/1000 x CURRENT x T MPERATUR€_CORRECTION) Howard Lamb,MSEE PV ELECTRICAL <br /> Circuits 2 and 3 will be the some or less current and same Length,so less voltage drop. Date; 11/6/22 Everett, WA 98201 CONFIGURATION DRAWING <br /> .36%69W Voltage Drop:Circuit 1 -(290w'11)1240v=13A,@ 240v @ 30ft one-way distance Signatures; <br /> .97V=1.2 x 2 x 30.0/1000x 15.7 x 0.838(DROP=IMPEDANCE per K_LENGTH x 2 x LENGTH/1000 x CURRENT x TEMPERATURE_CORRECTION) En (neer' <br /> Circuits 2 and 3 will be less current and same Length,so less voltage drop. <br />
The URL can be used to link to this page
Your browser does not support the video tag.