Laserfiche WebLink
CONTRACTOR INFORMATION <br /> NATIONWIDE SOLAR <br /> 5619 MILWAUKEE AVE E. <br /> PUYALLUP,98372,WA <br /> CSLB#aaameae913dc <br /> PHONE:253-7224-782 <br /> Email:cbitton911@comcast.net <br /> CCZA CCQ <br /> IP A ationWde:� <br /> ROUR�a CIP GROUP"" SOLAR <br /> Certificate:70131735 Master Contract:266909 0 <br /> Certificate of Complance Project: 80090260 Date Issued:2021-07-14 R.Al <br /> ,�wN,AION. ON ES asap»,.... <br /> NATWIDE SOLAR <br /> 6407 NE 117TH AVE.SUITE B <br /> VANCOUVER,WA 98662 <br /> Certificate: 70131735 Master Contract: 266909 EmailPHONE:(800)908-8992 <br /> :getsolar@mynationwidesolar.com <br /> The system listed is designed to provide bonding/grounding,and mechanical stability for photovoltaic modules. VERSION <br /> Project: 80090260 Date Issued: 2021-07-14 The system is secured to the roof with the L-Foot components through the roofing material to building structure. <br /> Modules are secured to the racking system with stainless steel or aluminum mid clamps and Aluminum end DESCRIPTION DATE REV <br /> clamps.The modules are bonded to the racking system with the stainless-steel bonding mid clamps with piercing INITIAL RELEASE 03/26/2022 UR <br /> Issued To: Unirac <br /> 1411 Broadway NE points.The system is grounded with 10 AWG copper wire to bonding/grounding lugs.Fire ratings of Class A <br /> Albuquerque,NewMexico,87102 with Type 1,2,3, 10, 19,22 or 25 for steep slope.Tested at 5"interstitial gap which allows installation at any <br /> United States stand-off height. <br /> Attention:Klaus Ncolaedis The grounding of the system is intended to comply with the latest edition of the National Electrical Code,to <br /> include NEC 250&690.Local codes compliance is required,in addition to national codes.All <br /> grounding/bonding connections are to be torqued in accordance with the Installation Manual and the settings used <br /> The products listed below are eligible to bear the CSA Mark shown with during the certification testing for the current edition of the project report. <br /> adjacent indicators 'C' and 'US'for Canada and US or with adjacent <br /> indicator 'US'for US only or without either indicator for Canada only. The system may employ optimizers/micro-inverters and used for grounding when installed per installation <br /> instructions. <br /> UL 2703 Mechanical Load ratings: <br /> PROJECT NAME <br /> Issued by: M6"" a'Ham' Downward Design Load(lb/ft ) 113.5 <br /> Michael Hoffnagle <br /> Upward Design Load(lb/ft ) 50.7 <br /> Down-Slope Load(lb/ft2) 16.13 (a/) c) <br /> ic <br /> ^ = <br /> Test Loads: - - <br /> C us = � b62E Ow <br /> Downward Load(]b/ft2) 170.20 Q Q > <br /> Upward Load(1b/ft2) 76.07 J � 0 cc::))0 O O 2 W <br /> Down-Slope Load(lb/ft2) 24.2 w Q M 10LL <br /> 0 >_ O <br /> PRODUCTS Z ti <br /> 00 Y) Z <br /> CLASS -C531302-POWER SUPPLIES-PHOTOVOLTAICS-PV Racking <br /> CLASS -C531382-POWER SUPPLIES-PHOTOVOLTAICS PV Racking and clamping systems-Certified Unirac Large Array O Z) <br /> to US Standards Q it c <br /> M W U <br /> ULA is a ground mount system using the SolarMount(SM)platform for the bonding and grounding of PV Z LO of Z J V . . <br /> modules.ULA aluminum components merge with SM rails and installer-supplied steel pipe. The SM rail system Lu 0- <br /> Models: <br /> Models: SM - SOLARMOUNT Flush-to-Roof is an extruded aluminum rail PV is secured to the horizontal Pipe using the Rail Bracket components. The Rear and Front cap secures the > Q Z Q <br /> racking system that is installed parallel to the roof in landscape or horizontal Pipe to the vertical Pipe.The Front cap is also used to secure the Cross brace.A Slider is attached to u j <br /> portrait orientations. the vertical Pipe to secure the Cross brace.The SM rails,caps,slider,rail brackets,and cross braces materials are <br /> 6105-T5 aluminum extrusion.Fasteners materials are 304 stainless steel. Horizontal and vertical pipe materials <br /> ULA - Unirac Large Array is aground mount system using the <br /> SolarMount (SM) platform for the bonding and grounding of meet the minimum requirements of ASTM A53 for galvanized steelpipe in 2"and 3"diameter. <br /> SHEET NAME <br /> PV modules. <br /> The mechanical load ratings from the SM test data will be applied to the ULA model. <br /> SPEC SHEETS <br /> Solarmount Fire Testing is not applicable due to being a ground mount system. <br /> SHEET SIZE <br /> LD ev <br /> D 507 R .2019-04-30 ©2018 CSA Grow. All r is reserved. Page 1 DOD 507 Rev.2019-04-30 ©2018 CSA Group. All rights reserved. Page 2 ANSI Z <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-20 <br />