Laserfiche WebLink
a ? <br /> w <br /> J Q <br /> •� o U) <br /> Enphase IQ Combiner 4/4C a <br /> Cath sileel MODEL NUMBERco <br /> Enphase Networking 10 Combiner 4(X-10-AMI.240-4) 10 Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering(ANSI p <br /> 012.20+/-0 5%)and consumption monitoring(+/-2 6%).Includes a silver solar shield to match the IQ Battery system and � <br /> lQ � <br /> System Controller 2 and to deflect heat. � <br /> IQ Combiner 4C(X-]Q-AMI-240-4C) IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering <br /> (ANSI C12.20+/-0.5`%,)and consumption monitoring(+/-2.5%).Includes Enphase Moblfe Connect cellular modem <br /> (CELLMODEM-MI-06-SP-OS),a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. <br /> (Ava <br /> le in <br /> USVIrgin <br /> s,where <br /> here is <br /> Enphase The Enphase IQ Combiner 4/4C with Enphase theInsbllatio areaCanada,Mexico,Puert shield <br /> to mat htheIQBatteryand10SytsstemCadeoller and to ular service <br /> SYSTEM INFO <br /> the Installation area.)Includes a silver solar shield to match the IO Battery and 10 System Controller and to deflect he;. (11)Q CELLS <br /> ACCESSORIES AND REPLACEMENT PARTS (not included,order separately) Q.PEAK DUO BILK ML-G10+ <br /> IQ Gateway and integrated LTE-M1 cell 40Dw <br /> Q Combiner 4/40 Ensemble Communications Klt -Includes COMMS-KIT-01 and CELLMODEM-M1 06-SP-05 with Syear Sprint data plan for <br /> modem (included only with IQ Combiner 4C) COMMS-CELLMODEM-Mt-06 Ensemble sites (11)ENPHASE <br /> cELLMODEM-M1-06-SP-O5 4G based LTE-Ml cellular modem with 5-year Sprint data plan IQ8PLUS-72-2-US 240V <br /> X-I Q-AM1-240-4 consolidates interconnection equipment CELLMODEM•MI.06-AT•05 413 based LTE-Mt cellular modem with 5-year AT&T data plan DC SYSTEM SIZE:4.40 kWDC <br /> Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. AC SYSTEM SIZE:3.30 kWAC <br /> X-IQ-AM1-240-4C into a single enclosure and streamlines 10 BRK-IOA-2-240V Circuit breaker,2pole.IOA,Eaton BR210 REVISIONS <br /> BRK-15A-2-240V Circuit breaker,2 pole.15A,Eaton BR215 <br /> microinverters and storage installations by BRK-20A-2P-240V Circuit breaker.2pole.20A.Eaton BR220 DESCRIPTION DATE REV <br /> BRK-15A-2P-240V-B Circuit breaker,2 pole,15A,Eaton BR215B with hold down kit support <br /> providing a consistent, pre-wired solution for ORK-20A-2P-24OV-B Circuit breaker,2 pole,20A,Eaton BR220B with hold down kit support <br /> residential applications. It offers up to four EPLC-01 Power line carrier(communication bridge pair),quantity one pair <br /> ( XA SOLARSHIELO ES Replacement solar shield for IO Combiner 4/4C <br /> 2 pole input circuits and Eaton BR series KA-PLUG-120-3 Accessory receptacle for Power Line Carrier In IQ Combiner 4/4C(required for EPLC-01) Signature with Seal <br /> bulbar assembly. XA-ENV-PCBA3 Replacement 10 Gateway printed circuit board(PCB)for Combiner 4/4C <br /> X-I0-NA-HD-125A Hold down kit for Eaton circuit breaker with screws <br /> ELECTRICAL SPECIFICATIONS <br /> Smart Rating Continuous duty <br /> Includes IQ Gateway for communication and control System voltage 120/240 VAC,60 Hz <br /> Includes Enphase Mobile Connect cellular modem Eaton BR series busbar rating 125A <br /> (CE LLMODEM-M1-06•SP-05),included only with IQ Max continuous current rating 65A <br /> Combiner 4C Max continuous current rating(input from FiV/storage) 64 A PROJECT NAME&ADDRESS <br /> Includes solar shield to match Enphase IQ Battery Max fuse/circuit rating(outpul) 90A <br /> aesthetics and deflect heat Branch circuits(solar and/or storage) Up to four 2 pole Eaton OR series Distributed Generation(DG)breakers only(not Included) <br /> Flexible networking supports WI-FI, Max total branch circuit breaker rating(Input) BOA of distributed generation i 95A vrith IQ Gateway breaker Included co <br /> i Ethernet,or cellular Production metering CT 20D A solid core pre-installed and wired to 10 Gateway v <br /> Optional AC receptacle available for PLC bridge > 00 <br /> Consumption monitoring CT(CT-200-SPLIT) A pair of 200 A split core current transformers J <br /> Provides production metering and consumption Cfl <br /> monitoring MECHANICAL DATA w m C"7 <br /> O O <br /> N <br /> Dimensions(WxHxD) 37.5 x 49.5 x 16.8 cm(14.75'x 19.5'x 6.63").Height is 21.06'(53.5 cm)wllh mourning brackets. Ld_ W N O <br /> Sim Ie Weight 7.5kg06.51bs) w it Z 06 CD <br /> O <br /> p Ambient temperature range -40°C to+46°C(-40°to 115°F) 00 <br /> ` , w n/ 00 <br /> Centered mounting brackets support single Goolmg Natural convection,plus heat shield vJ Q LLL 00 <br /> stud mounting NN r <br /> Enclosure envimr mental rating Outdoor.NRTL-ce(tified.NEMA type 3R,polycarbonate construction L 1. _ 'r'_Supports bottom,back and side conduit entry U) w O <br /> Up to four 2-pole branch circuits for 240 VAC Wire sizes 20 A to 50 A breaker inputs 14 to 4 AWG copper conductors LU <br /> •60 A breaker branch input.4 to 110 AWG copper conductors T / w <br /> • plug-in breakers(not Included) Main lug combined output.10 to 2/0 AWG copper conductors y <br /> X-IQ-AMI-240-4C 80A total PV or storage branch circuits Neutral and ground 14 to 1/0 copper conductors r, n/ Z <br /> Always follow local code requirements for conductor sizing. V �y.� LL a— <br /> Altitude To 2000 meters(6.560 feet) N w Q <br /> Reliable INTERNET CONNECTION OPTIONS w <br /> Durable NRTL-certified NEMA type 3R enclosure integrated Wi-Fl 802.11b/g/n <br /> i'eltutar CELLMODEM-MI06•SP-05,CELLMODEM,M1.06-AT-05(4Gbased LTE-Ml cellular modem) Note that an Enphase <br /> • Five-year limited warranty Mobile Connect cellular modern isrequired for all Ensemble installations. <br /> Two years labor reimbursement program coverage Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable(not included) <br /> included for both the IQ Combiner SKUs <br /> UL listed COMPLIANCE _ DATE:6/23/2022 <br /> Compliance,IQ Combiner UL 1741,CAN/CSA 022.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 <br /> Production metering:ANSI C12.20 accuracy class 0.5(PV production) SHEET NAME <br /> Consumption metering:accuracy class 2 5 <br /> OCompliance,IQ Gateway UL 606011/CANCSA 22.2 No.61070-1 EQUIPMENT <br /> X-IQ-AMl-240-4 <br /> SPECIFICATION <br /> LISTEDENPHASE ENPHASE <br /> To learn more about Enphase offerings,visit BnRha�e.c4a] �/ To learn more about Enphase offerings,visit enohase.com �./ SHEET SIZE <br /> 2 021 Enphase Fnergy All rights reserved Enphase,lire Enphase logo,1Q Goinbnlef 4/4C,and other nor oec are Itwemarks Of <br /> nphase Energy,Inc Data subject to change 10.21.2021 ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV_11 <br />