A B C D E F I G I H <br /> LOAD CALCS-TOTAL AMPS AVAILABLE MAX AC OPERATING CURRENT CALCS FOR HM-1200 MAX AC OPERATING TOTAL <br /> 120% TOTAL MAIN BREAKER MAX BREAKER SIZE #OF MICROINVERTERS MAX OUTPUT CURRENT - MAX AC OPERATING CURRENT CURRENT FOR HM-1200,600,300 <br /> BUS RATING <br /> 200A X 1.2 - 240 200E - EAK40A 3 X 5.OA - 15.00A HM-1200 HM-600 HM-300 <br /> MAX AC OPERATING CURRENT CALCS FOR HM-600 <br /> COMBINER BOX PANEL SIZE CALCS #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT 15.00A + 9.84A + 2.46A = 27.30A <br /> NUMBER OF NUMBER OF NORMINAL OUTPUT COMBINED 4 X 2.46A = 9.84A <br /> r CIRCUIT# MODULES MICROINVERTERS CURRENT TOTAL 125% TOTAL TOTAL BREAKER SIZE MAX AC OPERATING CURRENT CALCS FOR HM-300 <br /> CIRCUIT 1(1 of 3) 1 1 X 1.23A = 1.23A 1.25 = 1.54A #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT <br /> CIRCUIT 1(2 of 3) 2 1 X 2.46A = 2.46A x 1.25 = 3.08A = 17.11A = 20A 2 X 1.23A - 2.46A <br /> CIRCUIT 1(3 of 3) 8 2 5.OA = 10.00A x 1.25 = 12.50A <br /> CIRCUIT 2(1 of 3) 1 1 X 1.23A = 1.23A 1,25 = 1.54A BREAKER SIZE CALCS <br /> CIRCUIT 2(2 of 3) 6 3 X 2.46A = 7.38A x 1.25 = 9.23A = 17.01A = 20A <br /> CIRCUIT 2(3 of 3) 4 1 5.OA = 5.00A x 1.25 = 6.25A MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE <br /> 27.30A x 1.25 x 34.13A = 35A <br /> NOTES: <br /> 1. 200A UTILITY METER GLOBE ONLY.(EXISTING) <br /> 2. 200A LOAD CENTER.(EXISTING) <br /> 3. 60A RATED NON-FUSED LOCKABLE AC DISCONNECT. <br /> (NEW) <br /> N 4. 125A RATED COMBINER PANEL.(NEW) fV <br /> ALL CONDUIT SIZES ARE MINIMUM SIZES 1 UTILITY METER(E) <br /> ALL WIRE SIZES ARE FOR COPPER WIRE <br /> (qATG <br /> UTILITY <br /> RID(E) <br /> (2)8 AWG 2 <br /> (1)8 AWG EGC EXISTING <br /> wine AIN SERVICE PANEL(E) <br /> (2)8 AWG <br /> (1)8AWGEGC 3 <br /> p p 200 W <br /> MAIN SERVICE <br /> 4 / / DISCONNECT(E) <br /> 1 SUNTECH STP370S-B60/WNHB MODULE 2 SUNTECH STP370S-B60/WNHB MODULES 8 SUNTECH STP370S-B60/WNHB MODULES tt/�dI <br /> WITH HOYMILES HM-300 MICRO WITH HOYMILES HM-600 MICRO WITH HOYMILES HM-1200 MICRO <br /> INVERTER INVERTERS INVERTERS <br /> (1 OF 3) (2 OF 3) (3 OF 3) <br /> =s xs (2)8 AWG <br /> (1)8 AWG EGC <br /> �_ a 35A LOAD-SID <br /> 11 X21 11 X81 • • • X41 (31 X21 11 a SOLAR OCPD <br /> CIRCUIT#1 (Opposite end of the main disconnect <br /> on the busbar-NEC 705.12(B)(3) <br /> • • • (2)12 AWG <br /> (1)8 AWG EGC <br /> 1 SUNTECH STP370S-B601WNHB MODULE 6 SUNTECH STP370S-B60/WNHB MODULES 4 SUNTECH STP370S-B60/WNHB MODULES <br /> WITH HOYMILES HM-300 MICRO WITH HOYMILES HM-600 MICRO WITH HOYMILES HM-1200 MICRO <br /> INVERTER INVERTERS INVERTERS <br /> (1 OF 3) (2 OF 3) (3 OF 3) <br /> X11 X61 (2) X11 X41 X31 (2) X11 <br /> CIRCUIT#2 <br /> (2)12 AWG <br /> (l)8 AWG EGC <br /> Lf) C31 <br /> ti ti <br /> ~ LJ <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED CDR NOT TO SCALE <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Mario Lo re n za n a DATE: DESIGN <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> SO L Ez N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 10/14/2022 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P o W E R <br /> THE RECIPIENT'S ORGANIZATION, EXCEPT IN 4528 31 st Ave SE Everett Washington 98203 PAGE# <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 3 <br /> CONSENT FROM SOLGEN POWER. <br />