Laserfiche WebLink
A B I C D E I F G I H <br /> AERIAL VIEW ELECTRICAL NOTES GENERAL NOTES <br /> 1. WHERE ALL TERMINALS OF THE 1. PRIOR TO THE COMMENCEMENT OF ANY <br /> DISCONNECTING MEANS MAY BE WORK, THE CONTRACTOR SHALL NOTIFY <br /> ENERGIZED IN THE OPEN POSITION, A THE DESIGNER OF ANY DISCREPANCIES <br /> f SIGN WILL BE PROVIDED WARNING OF WITH THE DESIGN IN ANY CAPACITY. <br /> f THE HAZARDS. (PER ART. 690.17) ESPECIALLY RECOMMENDATIONS, CODES, <br /> 2. EACH UNGROUNDED CONDUCTOR OF OR REGULATIONS & RULES OF THE <br /> THE MULTIWIRE BRANCH CIRCUIT WILL AUTHORITY HAVING JURISDICTION, WHICH <br /> BE IDENTIFIED BY PHASE AND SYSTEM. SUPERSEDED THE NEC. <br /> (PER ART. 210.5) 2. ALL DIMENSIONS TO BE VERIFIED BY <br /> 3. A NATIONALLY RECOGNIZED TESTING CONTRACTOR PRIOR TO COMMENCEMENT <br /> _x LABORATORY SHALL LIST ALL OF WORK. <br /> EQUIPMENT IN COMPLIANCE WITH <br /> 3. CONTRACTOR IS RESPONSIBLE FOR ALL <br /> ARTICLE 110.3. SAFETY PRECAUTIONS, OSHA <br /> c\j ' . 4. ALL WIRES SHALL BE PROVIDED WITH REQUIREMENTS ETC. FOR THE SITE, N <br /> — -l STRAIN RELIEF AT ALL ENTRY POINTS INCLUDING EXISTING SITE HAZARDS. <br /> INTO BOXES AS REQUIRED BY UL LISTING <br /> 4. SYSTEM IS GRID INTERACTIVE/INTERTIED <br /> ( = 5. MODULE FRAMES SHALL BE GROUNDED VIA A UL LISTED POWER-CONDITIONING <br /> AT THE UL-LISTED LOCATION PROVIDED INVERTER. <br /> r: BY THE MANUFACTURER USING 5. SYSTEM HAS NO ENERGY STORAGE OF <br /> �• UL-LISTED GROUNDING HARDWARE. ANY KIND, OR UPS. <br /> 6. MODULE FRAMES, RAIL, AND POSTS 6. ALL SOLAR MOUNTING FRAMEWORK TO <br /> i r a SHALL BE BONDED WITH EQUIPMENT BE GROUNDED. <br /> +' GROUND CONDUCTORS AND GROUNDED 7. FOLLOW MANUFACTURERS SUGGESTED <br /> ' AT THE MAIN ELECTRICAL PANEL. INSTALLATION PRACTICES AND WIRING <br /> Co 7. THE DC GROUNDING ELECTRODE SPECIFICATIONS. <br /> Lo <br /> CONDUCTOR SHALL BE SIZED 8. ALL WORK TO BE IN COMPLIANCE WITH <br /> RESIDENCE PHOTO ACCORDING TO ARTICLE 250.166B & THE INTERNATIONAL BUILDING CODES. <br /> 690.47. (IBC) <br /> NN <br /> 69. ALL ELECTRICAL WORK TO BE IN <br /> ���10R JpNF COMPLIANCE WITH THE NATIONAL <br /> �oF�SHiNco ELECTRIC CODE (NEC). <br /> � Z <br /> 201148 8 Q7 <br /> SSONALEN <br /> 10/18/2022 <br /> ir �� <br /> L _ i,a. ' �, 4.,� _ STRUCTURAL ONLY <br /> rtl <br /> SHEET INDEX <br /> - <br /> �j5 � PV 1 COVER PAGE PV 5 MOUNTING DIAGRAM <br /> - r _ <br /> - --. �- .Y - PV 2 SITE PLAN PV 6 PLACARD <br /> PV 3 ELECTRICAL DIAGRAM CUT SHEETS ATTACHED <br /> PV 4 CHIKO MOUNTING <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED KMA CUSTOM <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS DESIGN <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER Daniel os m a n DATE: <br /> SOL r. N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 10/18/2022 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 705 Olympic Blvd Everett, WA 98203 PAGE# <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 1 <br /> CONSENT FROM SOLGEN POWER. <br />