Laserfiche WebLink
A B C D E F I G I H <br /> LOAD CALCS-TOTAL AMPS AVAILABLE MAX AC OPERATING CURRENT CALCS FOR HM-1200 MAX AC OPERATING TOTAL <br /> BUS RATING 120% I I TOTALMAIN BREAKER - MAX BREAKER SIZE #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT CURRENT FOR HM-1200&60 <br /> 200A X 1.2 - 240 200A 40A 8 X 5.OA - 40.00A HM-1200 HM-600 <br /> MAX AC OPERATING CURRENT CALCS FOR HM-600 <br /> COMBINER BOX PANEL SIZE CALCS #OF MICROINVERTERS MAX OUTPUT CURRENT MAX AC OPERATING CURRENT 40.00A + 2.46A = 42.46A <br /> NUMBER OF NUMBER OF NOMINAL OUTPUT COMBINED 1 X 2.46A = 2.46A <br /> CIRCUIT# MODULES MICROINVERTERS CURRENT TOTAL 125% TOTAL TOTAL BREAKER SIZE <br /> CIRCUIT 1 12 3 X 5.0A = 15.00A x 1.25 = 18.75A = N/A - 20A <br /> CIRCUIT 2 12 3 X 5.0A = 15.00A x 1.25 = 18.75A = N/A - 20A FUSE SIZE CALCS <br /> CIRCUIT 3(1 of 2) 2 1 X 2.46A = 2.46A x 1.25 = 3.08AMAX AC OPERATING CURR125% TOTAL FUSE SIZE <br /> CIRCUIT 3(2 of 2) 8 2 X 5.OA = 10.00A x 1.25 = 12.50A - 15.58A = 20A ENT 42.46A lxl 1.25 1 x I 53.08A I=I 60A <br /> UTILITY METER(E) <br /> NOTES: 1 <br /> 1. 200A UTILITY METER GLOBE ONLY.(EXISTING) O To UTILITY <br /> 2. 200A LOAD CENTER.(EXISTING) GRID(E) <br /> 3. 60A RATED FUSED LOCKABLE AC DISCONNECT WITH(2)60A FUSES.(NEW) <br /> N 4. 125A RATED COMBINER PANEL.(NEW) N <br /> ALL CONDUIT SIZES ARE MINIMUM SIZES (2)6 AWG EXISTING <br /> ALL WIRE SIZES ARE FOR COPPER WIRE (1)6 AWG NEUTRAL 2 WIRE AIN SERVICE PANEL(E) <br /> (2)6 Awc UPPLY-SIDE INTERCONNECTION <br /> (1)8 AWG EGC 3 NEC 705.11(6) <br /> VERIFY CONDUCTOR SIZE,4/0 AL <br /> OR 2/0 CU <br /> I J200 <br /> MAIN SERVICE <br /> DISCONNECT(E) <br /> 12 SUNTECH STP370S-B60/WNHB MODULES <br /> WITH HOYMILES HM-1200 MICRO <br /> co INVERTERS I I W <br /> $$ (2)6 AWG <br /> 8 <br /> 2 $� a& (1)8AWGEGC I II <br /> 1 • • • (41 (3) (✓) (1 L_ (1)SAWG EGC— J _ <br /> CIRCUIT#1 — <br /> • • • (2)12 AWG <br /> (1)8 AWG EGC <br /> 12 SUNTECH STP370S-B60/WNHB MODULES <br /> WITH HOYMILES HM-1200 MICRO <br /> INVERTERS <br /> (11 (41 (3) (21 (11 <br /> CIRCUIT#2 <br /> (2)12 AWG <br /> • • • (1 <br /> )8 AWG EGC <br /> ry ti <br /> 2 SUNTECH STP370S-B601WNHB MODULES 8 SUNTECH STP370S-B60/WNHB MODULES <br /> WITH HOYMILES HM-600 MICRO WITH HOYMILES HM-1200 MICRO <br /> INVERTERS INVERTERS <br /> (1 OF 2) (2 OF 2) <br /> (21 (11 (81 • • • (4) (3) (2) (11 <br /> LO CIRCUIT#3 cn <br /> (2)12 AWG <br /> • • • (1)8 AWG EGC <br /> ti <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED EMS NOT TO SCALE <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS Benjamin Dunham DATE: DESIGN <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER <br /> S D C N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5100 ELM RD, 03/12/2022 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN PAGE# <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 7206 Wetmore Ave. Everett, WA 98203 <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV 3 <br /> CONSENT FROM SOLGEN POWER. <br />