My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2320 RAILWAY AVE INTERWEST CONSTRUCTION INC 2023-02-02
>
Address Records
>
RAILWAY AVE
>
2320
>
INTERWEST CONSTRUCTION INC
>
2320 RAILWAY AVE INTERWEST CONSTRUCTION INC 2023-02-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/2/2023 9:39:15 AM
Creation date
1/24/2023 8:09:09 AM
Metadata
Fields
Template:
Address Document
Street Name
RAILWAY AVE
Street Number
2320
Tenant Name
INTERWEST CONSTRUCTION INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> INTERWEST-EVERETT CONTRACTOR'S YARD SITE IMPROVEMENTS <br /> ISANITARY SEWER PUMP CALCULATIONS <br /> 1.0 PROJECT SUMMARY <br /> This project proposes the construction of truck scales, a scale house, a wheel wash, asphalt paving, <br /> landscaping, sanitary sewer service, domestic water service, and power service. A new sanitary sewer <br /> I pumping station will serve the proposed scale house, due to the relatively flat nature of the site,together <br /> with the elevation of the existing pressurized City sewer main within the adjacent right-of-way. Based on <br /> the calculations and assumptions outlined herein, an E-One Pump Station Model DX152 will sufficiently <br /> serve the proposed scale house. <br /> 2.0 PEAK FLOW FROM BUILDING <br /> The proposed sanitary sewer pump station will need to pump (at a minimum) the anticipated peak flow <br /> from the scale house. <br /> Scale House: <br /> IQ = (d * CAP) * PF <br /> Where: <br /> Q = design flow (gpd) <br /> I d = average daydemand (gpppd) = 20 gpppd <br /> 9 <br /> CAP = expected instantaneous capacity = 10 people <br /> PF = peaking factor = 4.0 <br /> For design flow: <br /> Q = (20 * 10) * 4.0 = 200 * 4.0 = 800 gpd <br /> For total daily flow: <br /> I 800 gallons <br /> x 1 hour <br /> Q _ 8 hour day 60 minutes 1 6 gpm <br /> Given the pressure in the main at the point of connection is 22 psil, the proposed E-One Pump station <br /> will pump at a rate of 12.0 gpm.Therefore, the proposed pump station will adequately serve the <br /> proposed building. <br /> I <br /> I <br /> I <br /> 1 Based on email correspondence with Amie Roshak, P.E.with the City of Everett,the operating pressure is in the range of 15- <br /> 22 psi.The design conservatively assumes the upper limit. Reference attached email correspondence. <br /> SITTS & HILL ENGINEERS, INC. 1 <br /> TACOMA, WASHINGTON <br />
The URL can be used to link to this page
Your browser does not support the video tag.