DRY SIDE OF <br />WALL OR SLAB- <br />P, WALL SEAL <br />J <br />DETECTABLE MARKING TAPE <br />ff BELOW FINISH GRADE <br />(CONTINUE IF EXIST) <br />FINISHED GRADE <br />TRENCH EXCAVATION LIMITS <br />PER OSHA/WISHA, (TYP) <br />IMPORT STRUCTURAL BACKFILL <br />PIPE PER PLAN <br />PIPE ZONE BACKFILL <br />PIPE ZONE BEDDING <br />FOUNDATION LEVEL <br />FIRM TRENCH <br />FOUNDATION <br />CONDITION <br />4m <br />:® <br />PIPE PASSING THROUGH WALL <br />EPDXY GROUT DAYTON (J-55 <br />H.E.S) <br />LEGEND <br />CONTRACT EXCAVATION LIMITS <br />Illli,� <br />IIII= <br />III <br />Illf Lo <br />I' <br />PLASTIC COATED 14 GAUGE <br />(MIN,) TRACKING WIRE <br />(BLUE COVER). <br />CONTINUE IF ONE EXISTS <br />6Pe MIN. <br />DISPOSAL OF <br />- <br />OVER -EXCAVATED SOILS AND <br />INSTALLATION OF AUTHORIZED <br />OVER —EXCAVATION TRENCH <br />FOUNDATION BACKFILL <br />SOFT TRENCH <br />MATERIALS SHALL BE <br />FOUNDATION <br />DETERMINED BY THE <br />PIPE O.D. <br />CONDITION <br />GEOTECHNICAL ENGINEER AND <br />2� MIN. <br />AUTHORIZED BY THE OWNER. <br />TYPICAL WP,TE? SYSTEM TRENCH DETAIL <br />SCALE: N.T.S. <br />Lo <br />m <br />rn <br />to <br />Aw <br />2' <br />X <br />y�y q <br />�4 <br />I <br />�I <br />m SYM1 REVISION <br />I <br />® ORIG PIW UPGRADES ADDENDUM A <br />COAT AS FOR <br />SHACKLE. RODS VB� <br />4 TURNBUCKLES <br />2 TURNBUCKLES <br />9, —, THREAD 6/9 <br />THREAD 6 <br />r a�: ,cal <br />NEW CONC THRUST BLOCK ab <br />3000 PSI 0 28 DAYS <br />In <br />UNDISTURBED a <br />w IIII— <br />=1 I SUBGRADE <br />� IIIf= <br />s6 oC,v�. —III NEW CONC THRUST BLOCK <br />"S"=IIIIII II 3000 PSI @ 26 DAYS <br />11 1 /,V THRU 30® BENDS <br />TYPE "N' THRUST BLOCK TABLE <br />i <br />— <br />BLOCKTYPE "Y' THRUST <br />THRUST BLOCK NOTES: <br />1. THRUST BLOCK SLED PER NFPA24, LATEST EDITION. <br />2. SQUARE FEET OF CONCRETE THRUST —BLOCK AREA BASED ON <br />SAFE SOIL BEARING LOAD OF 2000 POUNDS PER SQUARE FOOT <br />AND WATER PRESSURE OF 200 PSI. <br />3. CONCRETE BLOCKING SHALL BE CAST IN PLACE AND HAVE A <br />MINIMUM OF 1/2 SQUARE FOOT BEARING AGAINST THE FITTING. <br />4. BLOCK SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE <br />CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING JOINT. <br />5. IN ADDITION TO THRUST BLOCKS, SECURE ALL JOINTS WITH <br />RETAINER GLANDS, TIE RODS, OR FLANGE FITTINGS, <br />6. NEW CONCRETE FOR THRUST BLOCKS SHALL BE 3000 psi <br />CONVEX VERTICAL BENDS <br />26 DAYS <br />TYPICAL THRUST L CK DETAILrS'� <br />BY APPROVED DATE SYM REVISION BY APPROVED DATE <br />J# 20808468 KJ JMF 01.25.21 <br />ACCEPTABILITY IJ. ,HOFFER <br />THRUST BLOCK NOTES: <br />1. THRUST BLOCK SLED PER NFPA24, LATEST EDITION. <br />2. SQUARE FEET OF CONCRETE THRUST —BLOCK AREA BASED ON <br />SAFE SOIL BEARING LOAD OF 2000 POUNDS PER SQUARE FOOT <br />AND WATER PRESSURE OF 200 PSI. <br />3. CONCRETE BLOCKING SHALL BE CAST IN PLACE AND HAVE A <br />MINIMUM OF 1/2 SQUARE FOOT BEARING AGAINST THE FITTING. <br />4. BLOCK SHALL BEAR AGAINST FITTINGS ONLY AND SHALL BE <br />CLEAR OF JOINTS TO PERMIT TAKING UP OR DISMANTLING JOINT. <br />5. IN ADDITION TO THRUST BLOCKS, SECURE ALL JOINTS WITH <br />RETAINER GLANDS, TIE RODS, OR FLANGE FITTINGS, <br />6. NEW CONCRETE FOR THRUST BLOCKS SHALL BE 3000 psi <br />CONVEX VERTICAL BENDS <br />26 DAYS <br />TYPICAL THRUST L CK DETAILrS'� <br />BY APPROVED DATE SYM REVISION BY APPROVED DATE <br />J# 20808468 KJ JMF 01.25.21 <br />ACCEPTABILITY IJ. ,HOFFER <br />THIS DESIGN AND/OR <br />CHECKED <br />SPECIFICATION IS APPROVED <br />M. SPAUR <br />rw—GWIIEER� <br />APPROVED BY DEPT. DATE <br />J. FISHER <br />ObEOKED <br />M. SPAUR <br />GENFRAJ.. NOTES <br />1. ALL MATERIALS USED, IE., HYDRANTS, VALVES, INDICATOR POSTS, RODS, <br />SHACKLES, VALVE BOXES, PIPE, FITTINGS, ETC., SHALL DE U.L. LISTED <br />AND FM APPROVED FOR USE ON FIRE PROTECTION SYSTEMS. SUBMIT <br />SPECIFICATIONS TO THE BOEING COMPANY FOR APPROVAL PRIOR TO <br />PROCUREMENT. <br />2. ALL FIREWATER DISTRIBUTION IMPROVEMENTS SHALL COMPLY WITH BOEING <br />STANDARD CONTROL DOCUMENT D36108-1. <br />3. ALL FIRE SYSTEM MODIFICATIONS SHALL CONFORM TO FACTORY MUTUAL <br />(F) GLOBAL LOSS PREVENTION DATA SHEETS: <br />3.1. 3-10: INSTALLATION AND MAINTENANCE OF PRIVATE FIRE SERVICE <br />MAINS AND THEIR APPURTENANCES. <br />4. ALL FIRE SYSTEM MODIFICATIONS SHALL CONFORM TO NATIONAL FIRE <br />PROTECTION ASSOCIATION (NFPA) DOCUMENTS: <br />4.1. NFPA 24: STANDARD FOR THE INSTALLATION OF PRIVATE FIRE <br />SERVICE MAINS AND THEIR APPURTENANCES. <br />5. ALL NEW UNDERGROUND FIRE MAIN SHALL BE FLUSHED WITH WATER PER <br />NFPA 24, CHAPTER 10.10. FLUSHING WATER SHALL BE FLOWING AT A <br />MINIMUM VELOCITY OF 10 FEET PER SECOND (1,600 GPM FOR 899 MAIN). <br />6. FIRE MAIN SHALL BE HYDROSTATIC TESTED PER NFPA 24, CHAPTER 10.10. <br />MINIMUM PRESSURE SHALL BE 200 PSI OR 50 PSI IN EXCESS OF <br />MAXIMUM STATIC PRESSURE WHEN MAXIMUM STATIC PRESSURE EXCEEDS <br />150 PSI. MINIMUM DURATION SHALL BE 2 HOURS. <br />7. ALL PIPE SHALL BE DUCTILE IRON, CEMENT LINED, EXTERIOR COATED, <br />THICKNESS CLASS 52, WITH FIELD LOCK 350 RESTRAINED JOINTSo <br />CEMENT�ORTAR LINING AND SEAL COAT PER ANS{/AWWA C104/A21.4. <br />8. FITTINGS SHALT BE DUCTILE IRON, CEMENT LINED, EXTERIOR COATED, <br />MECHANICAL JOINT OR FLANGED JOINT FITTINGS PER ANSI/AWWA <br />C110/A21.10. FLANGES SHALL HAVE ANSI CLASS 125 BOLT PATTERN. <br />FITTINGS SHALL BE CEMENT —MORTAR LINED AND SEAL COATED PER <br />ANSI/AWWA C104/A21.4. MINIMUM WORKING PRESSURE RATINGS FOR <br />FITTINGS AND FLANGES SHALL BE 250 PSIG OR GREATER. <br />9. JOINTS SHALL BE MECHANICAL, FLANGED, OR PUSH —ON PER ANSI/AWWA <br />C111/A21.11. FLANGES SHALL HAVE ANSI CUSS 125 BOLT PATTERN. <br />10. FOR MECHANICAL JOINTS, BOLTS AND NUTS SHALL COMPLY WITH <br />ANSI/AWWA C111/A21.11 AND ANSI AWWA C110/A21.10. OTHER BOLTS <br />SHAD BE ALLOY STEEL STUD BOLTS PER ASTM A193, GRADE B7, WITH <br />HEAVY HEX NUTS PER ASTM A194, GRADE 2H. <br />11. GASKETS FOR MECHANICAL AND PUSH —ON JOINTS SHALL BE VULCANIZED <br />NATURAL OR SYNTHETIC RUBBER PER ANSI/AWWA C111/A21.11. <br />12. GASKETS FOR FLANGED JOINTS SHALL BE FULL FACE CLASS 150, 1 /8 <br />INCH THICK, NON —ASBESTOS, NITRITE BINDER, GARLOCK BLUE —GAD 3000 <br />OR APPROVED EQUAL. <br />13. FIRE MAINS AND RELATED EQUIPMENT SHALL COMPLY WITH NFPA 24 AND <br />SHALL BE BURIED TO A MINIMUM DEPTH OF 4'46" <br />14, SCHEDULE WATER SYSTEM SHUT —OFFS WITH CONSTRUCTION MANAGER, <br />LIMIT SHUTOFF TO 8 HOURS IN ANY ONE DAY. <br />15. PIPE INSTALLATION SHALL CONFORM TO AWWA C600, SECTION 3.3; JOINT <br />ASSEMBLY SHALL CONFORM TO AWWA C600, SECTION 3.4. <br />16. SEE SHEET C693 FOR FIRE WATER DETAILS. <br />