Laserfiche WebLink
Permit#: PW2105-018 <br />Site Address: 3003 W CASINO RD i--51 <br />BOEING EVERETT FACILITI <br />Owner: <br />BOEING COMPANY <br />Tenant: <br />[Tenli <br />App= Date: <br />5/10/2021 <br />Proposed Use: <br />MANUF. <br />Description: <br />INSTALL DOUBLE WALL CONTAINMENT <br />PIPE FROM BLDG 40-51 <br />Reviewed BY // Date: e112__ <br />_dOffice Set Job Site Set Fire/Planning Set <br />APPROVED <br />PUBLICOM NT <br />BY <br />SAT t <br />CITY OF EVERETT REVIEWED FOR PERMIT <br />LOCATION MAP I SITE MAP I SCOPE OF WORK i CODE SUMMARY <br />SYMI I REVISION I BY <br />A I PIW UPGRADES ADDENDUM C - DCN-01 208084681 KJ <br />THIS PROJECT INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: <br />DESCRIPTION: INSTALLATION OF NEW AND REPLACEMENT OF <br />® PROVIDE AND INSTALL APPROXIMATELY 2800 FEET OF NEW PUMPED INDUSTRIAL WASTE <br />EXISTING PROCESS PIPING, ADDITION OF COVERED <br />(PIW) 4—INCH X 6—INCH SCHEDULE 10 STAINLESS STEEL X SCHEDULE 10 STAINLESS <br />TRENCHES. ADDITION OF NEW LEAK DETECTORS. <br />STEEL DOUBLE —CONTAINED PIPING OUTSIDE THE 40-51 BUILDING IN VAULT N4 OF <br />APPLICABLE BUILDING CODES: 2018 INTERNATIONAL BUILDING CODE AS ADOPTED <br />STEAM/UTILITY TUNNEL TO POINT OF CONNECTION (P.O.C.) NORTH OF BRIDGE AND <br />AND AMENDED BY THE CITY OF EVERETT AND <br />P.O.C. SOUTH OF BRIDGE TO STEAM/UTILITY TUNNEL TO 45-06 WATER TREATMENT <br />WASHINGTON STATE <br />PLANT (WTP) AND TANK FARM. <br />a RELOCATE/REPLACE EXISTING UTILITIES, INCLUDING BUT NOT LIMITED TO STORMWATER <br />2010 INTERNATIONAL MECHANICAL CODE <br />CATCH BASINS AND PIPING, AS MAY BE DESCRIBED IN CONTRACT DOCUMENTS AND <br />NECESSARY FOR THE INSTALLATION OF NEW PIPING AND TRENCHES. <br />2018 INTERNATIONAL FIRE CODE <br />® INSTALL NEW ASPHALT PAVING <br />CITY OF EVERETT DESIGN AND CONSTRUCTION <br />INSTALL NEW AND REPLACE EXISTING PIPE SUPPORTS <br />STANDARDS FOR DEVELOPMENT, REV. JANUARY <br />PROVIDE AND INSTALL NEW ELECTRIC HEAT TRACING AND INSULATION ON THE PIW <br />2018. <br />PIPING, VALVES AND APPURTENANCES OUTSIDE OF THE UTILIDORS AND TRENCHES <br />NFPA 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS <br />® PROVIDE AND INSTAL ISOLATION AND CHECK VALVES AS SHOWN IN THE DRAWING SET <br />CODE, AS REFERENCED BY THE 2015 IFC. <br />® PROVIDE AND INSTALL NEW LEAK DETECTION DEVICES, SIGNAL WIRING AND ASSOCIATED <br />PANELS FOR A COMPLETE AND OPERABLE SYSTEM <br />B31.3 PROCESS PIPING AS REFERENCED BY NFPA <br />a PROVIDE ASSOCIATED ELECTRICAL AND CONTROL CONDUIT, WIRING AND DEVICES FOR A <br />30 AND THE 2015 IFC. <br />COMPLETE AND OPERABLE SYSTEM. <br />o PROVIDE RECOATING/REPAINTING OF DEVICES, PIPING, CONCRETE, STEEL, SUPPORTS, <br />SEE STRUCTURAL NOTES SHEET FOR ADDITIONALCODES REFERENCED, <br />AND OTHER EXISTING APPURTENANCES AFFECTED BY THE WORK. <br />® REMOVE OR DEMOLISH MISCELLANEOUS EXISTING WORK, AS DESCRIBED IN THE <br />FLUID NOTES: CLASS 1110 COMBUSTIBLE FLUID; WATER THAT <br />CONTRACT DOCUMENTS <br />CONTAINS < 1 KETONE SOLVENTS AND SOME <br />® PROVIDE OTHER GENERAL WORK ASSOCIATED WITH THIS CONTRACT (CLEANING, <br />SOLIDS° <br />T <br />B31.3 FLUID CATEGORY: NORMAL <br />SCOPE REDUCTION. REMOVAL OF PIW 0600 AND ABANDONED LINE AND INSTALLATION OF <br />NEW PIW 0000 FROM MANHOLE F TO TH <br />PIPING NOTES: PIPING OUTSIDE OF EXISTING CONTAINMENT AREAS <br />WALL WILL BE PERFORMED BY OTHERS. <br />IS DOUBLE CONTAINED (SCHD. 10S CARRIER X <br />SCHD 10S CONTAINMENT) WITH LEAK DETECTION, <br />SUPPORT AND DESIGN PER IMC, MSS®SP—SB, AND <br />B31.3 (WHICHEVER IS MORE RESTRICTIVE). <br />HYDROSTATIC TESTING PER B31.3 TO 225PSIG. <br />CONTROLS AND INTERLOCKS: THE EXISTING SYSTEM HAS AUTOMATED <br />SWITCH —OVER TO THE NEXT SYSTEM HOLDING <br />TANK IF THE FIRST TANK BECOMES FULL, NO <br />CHANGE TO THIS AUTOMATION TO PREVENT <br />OVERFILL IS PLANNED FOR THIS WORK. <br />Lzm� APRIL 20, 1 <br />ROM <br />DRAWN DATE SUBTITLE <br />ACCEPTABILITY D. HOFFER 02.22.21 COVER SHEET <br />THIS DESIGN AND/OR CHECKED — -- - <br />SPECIFICATION IS APPROVED J. FISHER -- 02.22.211 TITLE PUMPED - INDUSTRIAL T <br />APPROVED BY DEPT. DATEE UPGRADES <br />J. FISHER 0Z22.21 <br />CHECKED <br />D. WD ---02.22.21 <br />APPROVED - <br />--- ,APPROVED —- (DISCIPLINE) MASTER <br />11 Jill 11 g <br />