Laserfiche WebLink
New---------- <br />Construction Retrofit <br />Application <br />over BUR <br />TYPICAL PHYSICAL PROPERTY DATA CHART <br />PER ASTM C 1289 _ POL yIsO FOAM CORE ONi y <br />Compressive <br />Strength ! ASTM D 1621 ! Grade 1 (109 psi <br />Dimensional Stability ` ASTM D 2126 < 0.5% linear change <br />' (7 days) <br />Water Absorption ASTM C 209 < 1 %volume <br />Flame Spread* I ASTM E B4 <br />< 75 <br />Smoke Developed* ! ASTM E 84 <br />I _ < 450 <br />Service Temperature ! 260° F < less <br />Recycle Content _ 9% - pre -consumer <br />*Meets the requirements of the IBC code. For specific Flame Spread or <br />Smoke Developed Ratings please contact the <br />Hunter Panels Technical Department <br />Insulation must be protected from open flame and kept dry at <br />all times. Install only as much insulation as can be covered the <br />same day by completed roof covering material. Hunter Panels will <br />not be responsible for specific building and roof design by others, <br />for deficiencies in construction or workmanship, for dangerous <br />conditions on the job site or for improper storage and handling. <br />Technical specifications shown in this literature are intended to be <br />used as general guidelines only and are subject to change without <br />notice. For more information refer to the Storage and Handling <br />Technical Bulletin at www.hunterpanels.com. or refer to PIMA <br />Technical Bulletin No. 109: Storage & Handling Recommendations <br />for Polyiso Roof Insulation at www.polyiso.org. <br />--HIE[ n HD <br />h <br />'" High -Density Potyisocyanurate Cover Board <br />Ballasted Single_PlySystems <br />Each H-Shield HD panel should be loosely laid as a cover board <br />over either an existing roof system or base layers of insulation <br />on the roof deck. Butt edges and stagger joints of adjacent <br />panels. Install the roof covering according to the manufacturer's <br />specifications. <br />Mechanically Attached Single -ply Systems <br />Each H-Shield HD panel should be secured as a cover board over <br />either an existing roof system or base layers of insulation. Butt <br />edges and staggerjoints of adjacent panels. Install the roof covering <br />according to the manufacturer's specifications. <br />Fully Adhered Single -Ply <br />Each H-Shield HD panel should be secured as a cover board over <br />either an existing roof system or base layers of insulation. H-Shield <br />HD may be adhered to a prepared concrete deck or subsequent <br />layers of insulation with a full mopping of hot steep asphalt, <br />insulation adhesive or cold applied mastic. Butt edges and stagger <br />joints of adjacent panels. Install the roof covering according to the <br />manufacturer's specifications. Either the dark side or the white <br />side may be installed face -up to allow for desired adhesive flash -off times. Install the roof covering according to the manufacturer's <br />specifications. <br />sy,_ d Modified Bitulnen Systems (APP, SBS) <br />Each H-Shield HD panel should be secured as a cover board over <br />either an existing roof system or base layers of insulation. H-Shield <br />HD may be adhered to a prepared concrete deck or subsequent <br />layers of insulation with a full mopping of hot steep asphalt, <br />insulation adhesive or cold applied mastic. Butt edges and stagger <br />joints of adjacent panels. Install the roof covering according to the <br />manufacturer's specifications. <br />REiGodiieg Siligie-Ply Systems <br />H-shield HD provides a singular and sustainable solution in retrofit <br />applications when existing insulation is left in place. To facilitate <br />compliance with ASHRAE 90.1 Standards for energy efficiency, <br />H-Shield HD can be installed in a single layer on top of intact and <br />dry insulation after the Single -Ply membrane is removed. Butt <br />edges and stagger the joints in accordance with good roofing <br />practice and fasten as per manufacturer's specifications. The new <br />Single -Ply membrane can then be installed over an insulation <br />assembly that complies with the latest energy code requirements. <br />FASTENING REQUIREMENTS* <br />_1-75 0.5 121 16 24 <br />1-90 0.5 1—' <br />16� * i <br />* Contact your membrane manufacturer for ter specific fastenin <br />NEGEN!PIMA I hig requirements -- <br />H U N+ E R <br />Hunter Panels i Energy Smart Polyiso 888.746.1114 i www.hunterpanels.com IN <br />iVew York Illinois Texas Utah Pennsylvania "�€" t e f.ncr } .tir ar, rof,rs,, <br />c.S.eaeS��:? <br />(�p �lo <br />