My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2020 BLDG 45-06 Plans 2023-01-26
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-06
>
Plans
>
3003 W CASINO RD 2020 BLDG 45-06 Plans 2023-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2023 9:46:17 AM
Creation date
1/25/2023 11:07:50 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-06
Permit
B2010-015
Year
2020
Notes
EXCAVATE AND POUR NEW SHALLOW CONCRETE TRENCH ON SOUTH SIDE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FlerrnllFf: t3zU_LU-U1� <br />Site Address: 3003 W CASINO RD #45-06 <br />Owner: ROEING COMPANY <br />BOEING COMMERCIAL AIRPLA JE GRO Tenant: BOEING #45-06 <br />App.Date: 10/9/2020 <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Description: EXCAVATE AND POUR NEW SFIALLOV <br />CONCRETE TRENCH ON SOUTH SIDE <br />Reviewed By: <br />yam✓ <br />Office Set <br />t. <br />'t <br />Ilk <br />- <br />4 <br />ry <br />S i= f3l Date: <br />fob Site Set Fire/PlanninE <br />CITY ov- yYIM <br />fRfEVIE VVED F r � <br />Additional Permits Are Required <br />For This Project To Include: <br />BOEING <br />EVERETT FACILITY <br />4 Plumbing,Sprinkler <br />3003 WEST CASINO ROAD <br />P qy p�,�{O BEEN <br />DOCUMENTS�(\Y� ltl@J� �J � 9`� <br />HAVE E <br />APPROVED FOR THE ISSUANCE Or <br />M"h�I�I�4d� <br />�®®� tl � O�W9 Alarm <br />59Y <br />EVERETT, <br />UBLIC WORKME(,�;• ANICAl , SIRE <br />J� iPPRESSION, ELECTRICAL OR <br />IQ <br />� Electrical <br />--UMBING <br />PR ITS' <br />LOCATION <br />MAP <br />SITE <br />MAP <br />SCOPE <br />OF WORK <br />CODE SUMMARY <br />On -site stormwater detention <br />construction <br />SR $26 <br />�45-01 �45-03 45-04 <br />� <br />5� <br />11 45 w�F <br />I —I H <br />H <br />THIS PROJECT INCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING: <br />DESCRIPTION: <br />INSTALLATION OF NEW AND REPLACEMENT OF <br />• PROVIDE AND INSTALL NEW PUMPED INDUSTRIAL WASTE (PIW) PIPING OUTSIDE <br />EXISTING PROCESS PIPING. ADDITION OF COVERED <br />BUILDING 45-01 TO THE 45-08 TANK FARM <br />TRENCHES. ADDITION OF NEW LEAK DETECTORS, <br />• PROVIDE AND INSTALL 0 2500 FEET OF NEW 4-INCH X 6-INCH SCHEDULE 10 <br />APPLICABLE BUILDING CODES: <br />2015 INTERNATIONAL BUILDING CODE AS ADOPTED <br />STAINLESS STEEL X SCHEDULE 10 STAINLESS STEEL DOUBLE -CONTAINED PIPE FROM A <br />AND AMENDED BY THE CITY OF EVERETT AND <br />POINT OF CONNECTION AT THE STEAM UTILIDOR EAST OF BUILDING 45-01 THROUGH <br />WASHINGTON STATE <br />THE EXISTING UTILIDOR AND TRENCH TO BUILDING 45-06, AS SHOWN IN DRAWING SET <br />® PROVIDE AND INSTALL NEW 4-INCH X 6-INCH SCHEDULE 10 STAINLESS STEEL X <br />2015 INTERNATIONAL MECHANICAL CODE <br />SCHEDULE 10 STAINLESS STEEL DOUBLE -CONTAINED PIPE IN A NEW TRENCH FROM <br />BUILDING 45-06 TO THE CONTAINMENT WALL OF THE TANK FARM, THEN EXITING THE <br />2015 INTERNATIONAL FIRE CODE <br />TRENCH AT THE TANK FARM WALL. PIPING TRANSITIONS TO A 4-INCH SCHEDULE 10 <br />STAINLESS STEEL SINGLE WALL PIPE WITHIN THE TANK FARM CONTAINMENT AREA AND <br />CITY OF EVERETT DESIGN AND CONSTRUCTION <br />CONNECTS TO AN EXISTING HEADER AS SHOWN IN THE DRAWING SET <br />STANDARDS FOR DEVELOPMENT, REV. JANUARY <br />• CONSTRUCT A NEW 5-FOOT BY 3-FOOT CONCRETE UTILITY TRENCH FROM BUILDING <br />2018. <br />45-06 TO TANK FARM <br />NFPA 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS <br />• RELOCATE/REPLACE EXISTING UTILITIES, INCLUDING BUT NOT LIMITED TO STORMWATER <br />CODE, AS REFERENCED BY THE 2015 IFC. <br />CATCH BASINS AND PIPING, AS MAY BE DESCRIBED IN CONTRACT DOCUMENTS AND <br />NECESSARY FOR THE INSTALLATION OF NEW PIPING AND TRENCHES. <br />831.3 PROCESS PIPING AS REFERENCED BY NFPA <br />• INSTALL NEW ASPHALT PAVING <br />30 AND THE 2015 IFC. <br />® INSTALL NEW AND REPLACE EXISTING PIPE SUPPORTS <br />SEE STRUCTURAL NOTES SHEET FOR ADDITIONAL <br />PROVIDE AND INSTALL NEW ELECTRIC HEAT TRACING AND INSULATION ON THE PIW <br />CODES REFERENCED. <br />PIPING, VALVES AND APPURTENANCES OUTSIDE OF THE UTILIDORS AND TRENCHES <br />• PROVIDE AND INSTALL ISOLATION AND CHECK VALVES AS SHOWN IN THE DRAWING SET <br />FLUID NOTES: <br />CLASS IIIB COMBUSTIBLE FLUID; WATER THAT <br />• PROVIDE AND INSTALL NEW LEAK DETECTION DEVICES, SIGNAL WIRING AND ASSOCIATED <br />CONTAINS <1% KETONE SOLVENTS AND SOME <br />PANELS FOR A COMPLETE AND OPERABLE SYSTEM <br />SOLIDS. <br />• PROVIDE ASSOCIATED ELECTRICAL AND CONTROL CONDUIT, WIRING AND DEVICES FOR A <br />831.3 FLUID CATEGORY: <br />NORMAL <br />COMPLETE AND OPERABLE SYSTEM. <br />• PROVIDE RECOATING/REPAINTING OF DEVICES, PIPING, CONCRETE, STEEL, SUPPORTS, <br />PIPING NOTES: <br />PIPING OUTSIDE OF EXISTING CONTAINMENT AREAS <br />AND OTHER EXISTING APPURTENANCES AFFECTED BY THE WORK. <br />IS DOUBLE CONTAINED (SCHD. 10S CARRIER X <br />• REMOVE OR DEMOLISH MISCELLANEOUS EXISTING WORK, AS DESCRIBED IN THE <br />SCHD 10S CONTAINMENT) WITH LEAK DETECTION. <br />CONTRACT DOCUMENTS <br />SUPPORT AND DESIGN PER IMC, MSS-SP-58, AND <br />® PROVIDE OTHER GENERAL WORK ASSOCIATED WITH THIS CONTRACT (CLEANING, <br />B31.3 (WHICHEVER IS MORE RESTRICTIVE). <br />HOUSEKEEPING, TESTING, GROUNDING, COMMISSIONING AND STARTUP SUPPORT, ETC.) <br />HYDROSTATIC TESTING PER B31.3 TO 225PSIG. <br />CONTROLS AND INTERLOCKS: <br />THE EXISTING SYSTEM HAS AUTOMATED <br />SWITCH -OVER TO THE NEXT SYSTEM HOLDING <br />TANK IF THE FIRST TANK BECOMES FULL. NO <br />CHANGE TO THIS AUTOMATION TO PREVENT <br />OVERFILL IS PLANNED FOR THIS WORK. <br />0 <br />N <br />_ <br />ISSUED FOR CONS 1 RUC i IO�1 <br />04-03-2020 <br />Kennedy/Jenks Consultants <br />32007 32nd All —South, Suite 100 <br />Federal Way, WA 07 <br />Ph. 253-835-64£400 <br />Fax 253-952-3435 <br />SYM <br />REVISION <br />_ BY <br />APPROVED <br />DATE <br />SYM <br />REVISION <br />BY <br />APPROVED <br />DATE <br />�� L 3p9� <br />o� q�APPROVED <br />�csv r <br />ACCEPTABILITY <br />SPETHIS DESIGN sAND/OR <br />N /ROVED <br />DRAWN <br />B. HOFFER <br />DATE <br />— <br />Shafl LE <br />COVER SHEET <br />PUMPED INDUSTRIAL V/i�STE UPGRADES <br />RA <br />CURRENT REVISION SYMBe� <br />SHEET <br />DALE <br />04.03.20 <br />-- <br />ISSUED FOR CONSTRUCTION JOB# 20808468 <br />KJ, <br />04.03.20 <br />CHECKED <br />APPROVED BY <br />DEPT. <br />DATE <br />ENGINEERE <br />S. CRAWFORD <br />10.02.19 <br />BUILDING 45-YD <br />(DISCIPLINE) MASTER COL. X-X/X-X EVERETT <br />GO <br />CHECKED <br />JOB No. 20880468 <br />DMP ND. <br />P ovm <br />DWG No 45-YD-GO <br />9� <br />Set <br />
The URL can be used to link to this page
Your browser does not support the video tag.