3003 W CASINO RD 2020 BLDG 45-06 Plans 2023-01-26
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-06
>
Plans
>
3003 W CASINO RD 2020 BLDG 45-06 Plans 2023-01-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2023 9:46:17 AM
Creation date
1/25/2023 11:07:50 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-06
Permit
B2010-015
Year
2020
Notes
EXCAVATE AND POUR NEW SHALLOW CONCRETE TRENCH ON SOUTH SIDE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 1705.3 <br />REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION <br />11014 OWN I I 1 11 1 <br />i <br />1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING <br />ACI 318: CH 20, 25.2, 25.3, <br />YES <br />TENDONS, AND VERIFY PLACEMENT. <br />_ - <br />X <br />26.5.1-26.5.3 <br />1908.4 <br />2. REINFORCING BAR WELDING: <br />NO <br />A. VERIFY WELDABILITY OF REINFORCING BAPS OTHER <br />-- <br />X <br />-- <br />THAN ASTM A706: <br />AWS D1.4 <br />ACI 318: 26.5.4 <br />NO <br />B. INSPECT SINGLE -PASS FILET WELDS, MAXIMUM 5/16" <br />-- <br />X <br />NO <br />C. INSPECT OTHER, WELDS. <br />X <br />-- <br />-- <br />YES <br />3. INSPECT ANCHORS CAST IN CONCRETE. <br />-- <br />X <br />ACI 318: 17.8.2 <br />— <br />4. INSPECT ANCHORS POST -INSTALLED IN HARDENED <br />CONCRETE MEMBERS? <br />A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR <br />YES <br />UPWAP,D INCLINED ORIENTATIONS TO RESIST SUSTAINED <br />X <br />— <br />ACI 318: 17.8.2.4 <br />-- <br />TENSION LOADS. <br />NO <br />B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT <br />X <br />ACI 318: 17.8.2 <br />-- <br />DEFINED IN 4.A. <br />YES <br />5. VERIFYING USE OF REQUIRED DESIGN MIX <br />-- <br />X <br />ACI 318: CH. 19, 213A.3, 26.4.4 <br />1904.1, 1904.2, <br />19DO 2, 1908.3 <br />Q PRIOR TO CONCRETE PIACEMENT, FABRICATE SPECIMENS <br />ASTM C172 <br />YES <br />FOR STRENGTH TESTS, PERFORM SLUMP AND AIR <br />X <br />-- <br />AS C31 <br />1908JO <br />DEBATERS <br />CONTENT TESTS, AND DETERMINE THE TEMPERATURE Of <br />ACI 318: 26.4.5, 26.12 <br />THE CONCRETE. <br />YES <br />7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR <br />X <br />-- <br />ACI 318: 26AL5 <br />1908.6, 1908.7, <br />PROPER APPLICATION TECHNIQUES. <br />1908.8 <br />YES <br />S. VERIFY MAINTENANCE OF SPECIFIED DURING <br />-- <br />X <br />ACI 318: 26.4.7-26.4.9 <br />1908.9 <br />TF.MPr'RATURE AND TECHNIQUES <br />9. INSPECT PRESTRESSED CONCRETE FOR: <br />NO <br />A. APPLICATION OF PRESTRESSING FORCES <br />X <br />-- <br />ACI 318: 26.9.2.1 <br />NO <br />B. GROUTING OF BONDED PRESTRESSING TENDONS. <br />X <br />-- <br />ACI 318: 26.9.2.3 <br />-- <br />YES <br />10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS. <br />-- <br />X <br />ACI 318: CH. 26.8 <br />-- <br />17. VERIFY IN-SUU CONCRETE STRENGTH, PRIOR TO <br />NO <br />STRESSING OF TENDONS IN POST -TENSIONED CONCRETE <br />AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM <br />X <br />ACI 318: 26.10.2 <br />BEAMS AND STRUCTURAL SLABS, <br />YES <br />12. INSPECT FORMWORK FOR SHAPE, LOCATION, AND <br />X <br />ACI 318: 26.10.1(b) <br />-- <br />DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED. <br />FOR SI: 1" = 25.4— <br />o. WHERE APPLICABLE, SEE ALSO SECTION 1705.12, SPECIAL INSPECTION FOR SEISMIC RESISTANCE. <br />I, . SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED <br />SOURCE IN ACCORDANCE WITH 17.82 IN ACI 318, OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT <br />PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE APPROVED BY <br />THE BUILDING OFFlCIAL PRIOR TO THE COMMENCEMENT OF THE WORK. <br />1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE <br />YES <br />ADEDUATE TO ACHIEVE THE DESIGN BEARING CAPACITY <br />X <br />2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER <br />X <br />YES <br />DEPTH AND HAVE REACHED PROPER, MATERIAL <br />3. PERFORM CLASSIFICATION AND TESTING OF <br />YES <br />COMPACTED FILL MATERIALS <br />X <br />4. VERIFY USE OF PROPER MATERIALS, DENSLTIES AND <br />YES <br />LIFT THICKNESSES DURING PLACEMENT AND <br />X <br />-- <br />COMPACTION OF COMPACTED FILL <br />5. PRIOR TO PLACEMENT OF COMPACTED FILL, <br />YES <br />OBSERVE SUBGRADE AND VERIFY THAT SITE HAS <br />-- <br />X <br />BEEN PREPARED PROPERLY <br />SYM REVISION BY APPROVED DATE SYM REVISION BY I APPROVED GATE <br />$ITE PUMPED INDUSTRIAL WASTE 20808468 SITTS BI_K UA 3.20 <br />ACCEPTABILITY <br />THIS DESIGN AND/OR <br />SPECIFICATION IS APPROVED <br />17- mi <br />1 Fib 2020 <br />SITTS & HILL <br />ENGINEERS, INC. <br />CIVIL = STRUCTURAL • SURVEYING <br />pvorvEE�sSa><-so<s I nx. �zsa�<>a-sms <br />Project No.: 17659 Project Mgr.: BKL <br />Prof. Engineer: EMF P,.E Drafter: JDK <br />60t 468 — — <br />SHELL <br />TITLE SITE PUMPED INDUSTRIAL WASTE <br />2F®5 <br />SITE 45-YD J0B No eC <br />STRUCTURAL EVERETT, WA DWG NO. 45-YD-S2F-5 <br />04.03.20 <br />