My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2019 BLDG 40-32 Plans 2023-01-25
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-32
>
Plans
>
3003 W CASINO RD 2019 BLDG 40-32 Plans 2023-01-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2023 3:49:26 PM
Creation date
1/25/2023 11:26:58 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-32
Permit
B1909-030
Year To
2019
Notes
STRUCTURAL SUPPORT OF CORROSION INHIBITOR COMPOUND EXHAUST
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br />POINT OF CONNECTION <br />15 115 14 14°5 15 GENERAL MOTES <br />1. THE BOEING EVERETT FIRE INSPECTION DEPARTMENT (425-342-2266) <br />SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ALL VALVE CLOSURES, <br />MATCH LINE -SEE DWG 40-032-3M261 FLUSHING, AND HYDROSTATIC TESTS ON THE FIRE PROTECTION SYSTEM. <br />O f THE MAXIMUM DURATION OF A SYSTEM CLOSURE IS S HOURS. <br />2. THE FIRE PROTECTION SPRINKLER SYSTEM PIPING SHALL BE DESIGNED PER <br />NFPA #13, ORDINARY PIPE SCHEDULE AND PIPE SPACING. PIPE HANGERS <br />i I i SPACING SHALL BE PER NFPA #13. <br />I I <br />3. A CONTRACTOR'S MATERIAL AND TEST CERTIFICATE WILL BE REQUIRED UPON <br />COMPLETION OF THE TESTING. THE CERTIFICATE MUST BE SIGNED OFF BY <br />THE BOEING EVERETT FIRE INSPECTOR DEPARTMENT PRIOR TO COMMENCING <br />ADDITIONAL WORK ON THE FIRE PROTECTION SYSTEM. <br />I j 4. FIRE PROTECTION PIPING SHOP DRAWINGS SHALL BE SUBMITTED TO BOEING <br />I I I FIRE PROTECTION ENGINEERING AND MUST BE APPROVED BEFORE ANY <br />MODIFICATION TO THE FIRE PROTECTION PIPING SYSTEM BEGINS. <br />ALL SPRINKLER PIPING 3" AND SMALLER SHALL BE SCHEDULE 40 ASTM <br />A-53, GRADE B, BLACK STEEL. ALL PIPING 4" AND LARGER SHALL BE <br />ASTM A-53, GRADE B, SCHEDULE 40 FOR VERTICAL RISERS AND MAY BE <br />SCHEDULE 10 FOR HORIZONTAL CROSS MAINS. <br />6. SPRINKLER SYSTEM PIPE FITTINGS SHALL BE 150 LB. THREADED MALLEABLE <br />i IRON FOR 11/" AND SMALLER, AND VICTAULIC GROOVED FITTINGS FOR 2%" <br />AND LARGER . PIPE FITTINGS FOR 2" MAY BE EITHER 150 LB. THREADED <br />MALLEABLE IRON OR VICTAULIC GROOVED. <br />7. COUPLINGS FOR GROOVED PIPE AND FITTINGS SHALL BE VICTAULIC STYLE <br />07 ZERO -FLEX UNLESS OTHERWISE NOTED. <br />S. HYDROSTATIC TEST: PRESSURE - 225 PSIG, DURATION -- 2 HOURS, <br />I I I I I I I <br />SEISMIC BRACING SHALL BE INSTALLED IN ACCORDANCE WITH FM <br />STANDARDS. SEE FM DATA SHEETS 2-8, "EARTHQUAKE PROTECTION FOR <br />WATER -BASED FIRE PROTECTION SYSTEMS" FOR SPECIFIC DETAILS. <br />I 10. AUTOMATIC SPRINKLER HEADS SHALL BE 165 DEGREE F. TEMPERATURE <br />I I <br />LO RATED. <br />N � <br />11. ALL EQUIPMENT SHALL BE UL LISTED AND FM APPROVED FOR FIRE SERVICE. <br />cN <br />CD 12. THE FIRE SPRINKLER SYSTEM PIPING FOR THE DUCT EXHAUST SYSTEM <br />i C SHALL BE HYDRAULICALLY DESIGNED IN ACCORDANCE WITH NFPA-13, <br />---A-NFPA-33 AND BOEING FIRE DEPARTMENT REQUIREMENTS. A MINIMUM OF 30 <br />GPM AT 15 PSIG IS REQUIRED A THE FIRE SPRINKLER IN THE CALCULATION <br />c' ® PER NFPA-33, THE QUANTITY OF SPRINKLERS INCLUDED IN THE HYDRAULIC <br />L� Ll; CALCULATION SHALL EQUATE TO THE QUANTITY OF SPINKLERS ALONG 100 <br />CO `f' 0 FT, HORIZONTAL OF DUCTWORK BASED ON SPRINKLERS BEING SPACED <br />7-1 <br />O ST STI 0 N NOTES <br />1 PROVIDE IN -DUCT WET PIPE FIRE SPRINKLER PROTECTION IN CIC EXHAUST <br />- DUCTWORK AS SHOWN. <br />I I <br />2. PROVIDE A FLEXHEAD SPRINKLER DROP CONNECTION WITH DUCT MOUNTING <br />BLACK, WAX COATED SPRINKLER HEAD WITH POLY BAG FOR EACH <br />I I I IN -DUCT SPRINKLER HEAD SHOWN. <br />i I 3. PROVIDE WET PIPE FIRE SPRINKLER PROTECTION FOR EXHAUST DUCT <br />i SYSTEM AS SHOWN. ROUTE MAIN SUPPLY PIPING DOWN TO SPRINKLER <br />MANIFOLD. <br />MODIFY EXISTING FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH BOEING <br />FIRE PROTECTION ENGINEERING STANDARD D35105-F, NFPA-13, FM 2-8 <br />AND FM 2-8N, APPLICABLE CODES AND BOEING FIRE DEPARTMENT <br />I I REQUIREMENTS. FIRE SPRINKLER SHOP DRAWINGS SHALL INCLUDE THE <br />SPRINKLER CONTROL VALVE TAG AND LOCATION FOR THE CONTROL VALVE <br />- _ ----- - --- ----------------- - ---------------------- --- --- -- ------ ---- - - -------- ----- ---- -- - -------------------- ------------ -- - THAT SERVES THIS AREA. <br />ri RL <br />5. COORDINATE SPRINKLER HEAD PLACEMENT AND PIPE ROUTING WITH ALL <br />DISCIPLINES, INCLUDING NEW AND EXISTING MECHANICAL AND ELECTRICAL <br />I I <br />DISCIPLINES. PROVIDE ADDITIONAL PIPING AND SPRINKLERS AS REQUIRED. <br />® p � 0 Q � E3 6 DEFER FIRE PROTECTION PIPE SIZING TO LICENSED FIRE PROTECTION <br />jP <br />-' ul' CONTRACTOR. <br />- -------------------- --- ------------- ---- ------------ -- - -- - - 111 13 15 17 <br />T 1 41 43 SECTION PICK UP I 11 1 14 16 - --- - _ - - - <br />� -----=- _� '' '� UNIT 1 � D {� <br />3M260 3M261 3M262 <br />IVIA <br />EH <br />---- <br />3M263 jM264�1 31-1265 E <br />-„ -- - � — --------- I 3 M 266 3 M 26 7 3M263 <br />k_ --- - F\;',% % KEY PLAN BLDG. 40Li <br />-032 <br />r----_--------r� � � SCALE: NONE N II! ! 80x2O CIC DUCT Rm9 ) <br />----- - ---- - ------ ---- - --- - TO 46/4� SECTIO3M264, 3M265, MOS M 12 S 4 0 4 S 16 <br />45x10 UP J & I TOOL (TYP.) <br />2-1 /299F I ----- - -- - - ---- - - ,9 9 99 <br />12 -1 /29,F _-1 60x20 U P -- -- -------------- -- f _ / <br />45x 10 r _ CIC D CT A SCALE, 1 S -1 -0 <br />n 299F 279F 29,F 2"F ! 2"F 2' F 1-1 299E 1-1 19F 1-1 4" F 1 99F 3M 14 M520 <br />CIC DUCT- 2-1 /2 F I I / / / X2 <br />3 F DN 2 F UP MATCH LINE - SEE DWG 40-032®3M267 <br />FIRE PROTECTION 6 www,brph.com Copyright©2019 <br />SPRINKLER PIPE <br />PARTIAL THIRD FLOOR FIRE PROTECTION P LAIC CONTINUES ONArchitects Engineers, Inc. <br />/ ' '9 SHEET 3 M 2 65 19020 33rd Ave W, Suite 530 State of Washington <br />SCALE: 1 / =1 —Q PROFESSIONAL STAMP �e SIGNATURE Certificate of Authorization <br />APPLIES TO WORK WITHIN THE CLOUDED Lynnwood, Washington, 98036 Architecture No. 603235512 <br />REVISION AREAS ONLY AS INDICATED 425-921-3500 Engineering No. 3137 <br />
The URL can be used to link to this page
Your browser does not support the video tag.