WIRING DIAGRAM SYMBOLS <br />,GROUNDIN <br />GROUND CABLE CONNECTION <br />GROUND ROD CONNECTION <br />GROUND CABLE PIGTAIL <br />G <br />GROUND CABLE (UNDERGROUND) <br />EQUIPMENT/STRUCTURAL GROUND CONNECTION <br />POWER- <br />PANELBOARD, 206Y/120V, 3 PHASE <br />PANELB A D, 480V OR 480V277V, 3 PHASE <br />EQUIPMENT IDENTIFICATION <br />"X" DENOTES EQUIPMENT NUMBER <br />"Y" DENOTES HP OR AMPS <br />SPECIAL PANELBOARD/ENCLOSURE (TYPE AS NOTED) <br />OJ <br />ENCLOSED CIRCUIT BREAKER DISCONNECT <br />(SIZE AS NOTED) <br />VARIABLE SPEED MOTOR STARTER <br />SOLID STATE MOTOR STARTER <br />SWITCH (FUSED R U FUSED) <br />0/20 <br />SWITCHECT <br />RATING/FUSE RATING <br />EP <br />MAGNETIC MOTOR STARTER (COMBINATION) <br />MANUAL MOTOR STARTER <br />T <br />TRANSFORMER (SIZE AS SHOWN, IN KVA) <br />JUNCTION BOX <br />ESTOP SWITCH e MAINTAINED <br />PULL BOX <br />HAND HOLE <br />PH <br />MAN HOLE <br />OFF/ON SELECTOR SWITCH CONTROL STATION <br />STOP -START PUSHBUTTON CONTROL STATION <br />460 VOLT MOTOR (SIZE AS NOTED) <br />0 <br />208 VOLT OR 240 V MOTOR <br />(SIZE AS NOTED) <br />115 VOLT MOTOR (SIZE AS NOTED) <br />CONTACTOR <br />$T <br />MECHANICAL TIMERS ITCH <br />SOLENOID VALVE <br />CORD REEL <br />CONDUIT <br />& WIRE <br />CONDUIT SURFACE MOUNTED OR CONCEALED. <br />E <br />CONDUIT IN WALL OR CEILING SPACE. <br />CONTAINS ONE AWG #12 PHASE, AND ONE <br />AWG #12 NEUTRAL CONDUCTOR UNLESS <br />OTHERWISE NOTED® "E" INDICATES <br />EMERGENCY CIRCUIT. <br />-®®®®®®®m <br />CONDUIT UNDERGROUND, UNDER FLOOR SLAB, <br />OR IN CEILING SPACE OF FLOOR BELOW WITH <br />CONDUCTORS AS ABOVE® <br />.0. <br />CONDUIT ONLY® <br />FLEXIBLE METAL CONDUIT. PROVIDE CIRCUIT <br />CONDUCTORS REQUIRED BASED ON 60 DEGREE <br />CELCIUS CONDUCTOR RATING® <br />INDICATES PHASE CONDUCTOR <br />(12 OR SIZE AS NOTED) <br />INDICATES NEUTRAL CONDUCTOR <br />( 12 OR SIZE AS NOTED) <br />INDICATES GROUND CONDUCTOR <br />( 12 OR SIZE AS NOTED) <br />INDICATES ISOLATED GREEN GROUND CONDUCTOR <br />( 12 OR SIZE AS NOTED) <br />10 <br />HOERU W/7 10 SHOWING CIRCUIT <br />SOURCE (PANEL/PANEL POSITION) <br />1 D6®1 /1,,5,7 <br />HOERU W/CIRCUIT SOURCE & CONDUIT <br />1 B2-8/1,3,5 <br />WIRE SIZE NOTED <br />1®1 /22°C932+2/ON+26G <br />SYM <br />REISI®N <br />BY <br />APPROVED <br />DATE <br />ae <br />DGEING EVERETT SITE STORMWATER UPGRADE 25065486 <br />KJ <br />ZCD <br />03.05.21 <br />CONDUIT & WIRE CONT'D <br />� CONDUIT TURNS DOWN <br />CONDUIT TURNS UP <br />CONDUIT SEAL <br />CABLE TRAY <br />POWER <br />120V, 15A, 1 PHASE, 2 POLE, 3 WIRE <br />RECEPTACLE, NEMA 5®15, HUBBELL #5262 <br />120V, 15A, 1 PHASE, 2 POLE, 3 WIRE, <br />DUPLEX CORD DROP RECEPTACLE, NEMA 5-15, <br />HUBBELL #5262 <br />20 <br />120V, 20A, 1 PHASE, 2 POLE, 3 WIRE, <br />RECEPTACLE, NEMA 5®20, HUBBELL #5362 <br />30 <br />120V, 30A, 1 PHASE, 2 POLE, 3 WIRE, TWISTLOCK <br />RECEPTACLE, NEMA L5®30, HUBBELL #2610A <br />120V, 15A, 1 PHASE, 2 POLE, 3 WIRE <br />DOUBLE DUPLEX RECEPTACLE, NEMA 5-15R, <br />HUBBELL #5262 <br />pa 30 <br />208V, 30A, 3 PHASE, 4 WIRE, 4 POLE GROUND <br />THRU SHEEVE (STYLE 1). CROUSE HINDS <br />ARE3412 <br />30 <br />208V, 3A, 1 PHASE, 2 WIRE, 3 POLE, <br />CORD DROP WITH TWISTLCK, NEMA L®30, <br />HUBBELL #2623 <br />pe <br />4 0V, 30A, 3 PHASE, 4 POLE, WIRE GROUND <br />30 <br />THROUGH EXTRA POLE, CROUSE HINDS #ARE 3423 <br />WP <br />15A, 125V, DUPLEX IN A WEATHERPROOF ENCLOSURE <br />(NEMA 3R RAINTIGHT) <br />GFI <br />1A, 125V, DUPLEX WITH BUILT IN GROUND FAULT <br />CIRCUIT INTERRUPTER, HUBBELL GF52621 <br />Rfl <br />FLOOR COX WITH 2OA 120V FOURPLEX AND <br />DATA COMPARTMENT <br />10 <br />208V, 20A, 1 PHASE, 2 POLE, 3 WIRE, TWISTLOCK <br />RECEPTACLE, NEMA L®30R, HUBBELL #2320A <br />509 <br />NEMA 14-50R STRAIGHT BLADE, 120/208V, <br />10, 3-POLE, ®WIRE RECEPTACLE, 50A. <br />FIRE <br />DETECTION <br />ME <br />DATA Z NETWORK <br />R3 1 <br />BRANCH <br />CIRCUIT NUMBER <br />LCP <br />RELAY IDENTIFICATION <br />Ld <br />LIGHTING CONTROL SWITCH, LOW VOLTAGE <br />E #RS237 <br />CLASS 1 DIVISION 1; <br />LARSON EP®2XP ®SG®DP S <br />OCCUPANCY SENSOR, LOW VOLTAGE <br />E #CDT®20®6®R <br />CLASS 1 DIVISION 1: <br />LARSON XP® S®N4X®AT®LV®V7 <br />P <br />DAYLIGHT PHOTOCELL, LOW VOLTAGE <br />GE PD®I <br />LCP <br />LIGHTING CONTROL PANEL <br />RCP <br />RECEPTACLE CONTROL PANEL <br />1111131i'mi <br />T <br />) <br />CIRCUIT BREAKER <br />I <br />Y <br />(DRAW -OUT TYPE) <br />POTENTIAL TRANSFORMER <br />2 <br />480:120 <br />& RATIO <br />�,, <br />ASNTITY <br />SHOWN <br />CURRENT TRANSFORMER <br />800:5 <br />QUANTITY & RATIO <br />AS SHOWN <br />A � <br />AMMETER w/SWITCH <br />V � <br />VOLTMETER w/SWITCH <br />tm) <br />WAifHOUR METER <br />PANELBOARD <br />(RATINGS AS <br />NOTED) <br />PANELBOARD <br />(RATINGS AS <br />- w I a NOVI IN I m u -` <br />CONTROL PANELS <br />A01 <br />-- <br />PANEL TERMINAL WITH NUMBER <br />851-555 <br />PANEL WIRING WITH WIRE NUMBER <br />851-666 <br />_ _ <br />FIELD WIRING WITH WIRE NUMBER <br />N <br />TERMINAL IN MCC <br />0 <br />TERMINAL IN PLC CONTROL PANEL <br />O <br />REMOTE TERMINAL FIELD <br />O <br />PANEL DEVICE TERMINAL <br />m <br />CONTROL PANEL TERMINAL <br />m <br />FLEX I/O TERMINAL <br />do-- <br />FUSE <br />(F OPTION) <br />GROUND CONNECTION <br />IIJ60 <br />L.V. DISCONNECTS ITCH <br />N NON FUSED) <br />/ <br />PILOT LIGHT <br />SWITCH RATING <br />INDICATES COLOR <br />I <br />K <br />INTERLOCK <br />K=KEY <br />PUSHBUTTON <br />® ECHANIC L <br />MOMENTARY CONTACT <br />E=ELECTRICAL <br />NORMALLY OPEN <br />XX <br />FEEDER TYPE <br />PUSHBUTTON <br />MOMENTARY CONTACT <br />DESIGNATION <br />NORMALLY CLOSED <br />AVAILABLE FAULT <br />XXX XXX <br />OFF ON <br />SELECTOR SWITCH <br />MAINTAINED <br />CURRENT {CLOSED <br />CONTACT <br />TRANSITION/NORMAL) <br />0- <br />TWO POSITION <br />2 <br />XXX XXX <br />EQUIPMENT AIC RATING <br />1 3 <br />1 <br />SELECTOR SWITCH <br />XXX <br />APPROXIMATE FEEDER <br />®2 <br />MAINTAINED CONTACT <br />LENGTH IN FEET T <br />THREE POSITION <br />BE CONFIRMED LATER. <br />3 <br />SOLENOID VALVE <br />PRESSURES ITCH e N.C. <br />® <br />OPENS ON RISING PRESSURE <br />PRESSURE SWITCH ® N.O. <br />CLOSES ON RISING PRESSURE <br />FLOAT OR LEVEL SWITCH ® N.C. <br />® <br />OPENS ON RISING LEVEL <br />VFD <br />FLOAT OR LEVEL SWITCH ® N.O. <br />CLOSES ON RISING LEVEL <br />FLOW SWITCH o N.C. <br />OPENS ON INCREASE IN FLOW <br />TEMPERATURE SWITCH - N.O. <br />CLOSES ON RISING TEMP <br />LIMIT SWITCH - N.C. <br />LIMITS ITCH ® N.O. <br />- <br />RELAYS & COILS <br />=TYPE <br />M®MOTOR STARTER <br />CR�CONTROL RELAY <br />C=CONTACTOR <br />TR=TIME DELAY OR TIMING <br />RELY <br />N.O. CONTACT <br />N.C. CONTACT <br />N.O. Q ON DELAY CONTACT <br />N.C. ON DELAY CONTACT <br />N.O. OFF DELAY CONTACT <br />N.C. OFF DELAY CONTACT <br />ACCEPTABILITY <br />, <br />!}� <br />a <br />-- <br />AND <br />ELECTRICALTHIS <br />CHEMM-0 <br />DESIGN AND/OR <br />SPECIFICA110N IS APPR_J. <br />Mohr <br />i_ <br />13Y <br />WV W <br />DEPT. <br />'!Z. Devlin <br />jAPPIRIOVED <br />1 " <br />19 ff 11"P <br />